PV76-30A Proportional Flow Control Cartridge,
DESCRIPTION
A solenoid-operated, electrically-variable, three-port, pressure-compensated, spool-
type, normally closed when de-energized, proportional fl ow control valve. It can be
used as a priority-type fl ow regulator with pressure-compensated, regulated and
bypass fl ow. It can also be used as a restrictive-type 2-way, pressure-compensated
ow regulator when the bypass line (port
) is blocked.
OPERATION
The PV76-30A will regulate fl ow out of port regardless of system working pressure.
With increasing current applied to the solenoid, output fl ow will increase.
Note: When used as a bypass fl ow control in applications where the priority fl ow port
will be blocked by external valving, bypass pressure drop will increase unless a small
amount of leakage is provided for the priority port. Consult factory.
Operation of Manual Override: To Engage: Turn clockwise approximately 1 turn to
reach start point. Continue another approximately 5 turns to full shift. To Disengage:
Turn counterclockwise approximately 6 turns to positive stop.
FEATURES
Excellent linearity and hysteresis characteristics.
Hardened spool and cage for long life.
Optional coil voltages and terminations.
Effi cient wet armature construction.
RATINGS
Operating Pressure: Inlet: 240 bar (3500 psi); Ports and : 207 bar (3000 psi)
Regulated Flow Rate: Range A: 3-Ported: 94.6 lpm (25.0 gpm)
Range A: 2-Ported: 85.2 lpm (22.5 gpm)
Nominal Input Flow: Bypass Open, 3-Ported: 121 lpm (32.0 gpm)
Maximum Input Flow: Bypass Open, 3-Ported: 151.4 lpm (40.0 gpm)
Internal Leakage: 0.38 lpm (0.10 gpm) at zero current
Electrical: 2 standard voltage ratings
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: VC16-3; See page 9.116.1; Cavity Tool: CT16-3X-XX; See page 8.600.1
Seal Kit: SK16-3X-MM; See page 8.650.1 for seal kit options
and appropriate seals based on application temperature range.
USASI/ISO:
SYMBOLS
2.376.1
PERFORMANCE
Threshold Current
300 ± 100 mA
150 ± 50 mA
Coil Voltage
12 VDC
24 VDC
Max. Control Current
1600 ± 100 mA
800 ± 50 mA
3
2
1
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROLS
2010
PERCENT OF MAX. CONTROL CURRENT
FLOW lpm/gpm
40 5030 60 70 80 90 100
113.5/30
94.6/25
75.7/20
56.8/15
37.9/10
18.9/5
3-WAY VALVE
Regulated Flow vs. Current
240 bar/3500 psi Inlet
207 bar/3000 psi at Port
; No Load at Port
12V Coil; 110 Hz PWM
32 cSt/150 sus oil at 40°C
PRESSURE bar/psi
Reg. P > Byp. PByp. P > Reg. P
FLOW lpm/gpm
0138
2000
138
2000
276
4000
276
4000
113.5/30
94.6/25
75.7/20
56.8/15
37.9/10
18.9/5
3-WAY VALVE
Regulated Flow vs. Load
240 bar/3500 psi, 121 lpm/32 gpm Inlet
12V Coil; 110 Hz PWM
32 cSt/150 sus oil at 40°C
1.60 amp
1.25 amp
1.0 amp
0.7 amp
0.4 amp
HYDRAFORCE
.com
®
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
Blue rectangles are links to other catalog pages.
PV76-30ANormally Closed
DIMENSIONS
2.376.2
75.1
2.96
3
3
2
2
1
1
44.1
1.74
50.8
2.00
101.6
4.00
50.3
1.98
119.9
4.72
101.0
3.98
96.8
3.81
30.0
1.18
MILLIMETRE
INCH
25.4
1.00
8.74
0.34
4.76
0.18
54.0
2.13
111.1
4.38
127.0
5.00
92.1
3.63
38.1
1.50
ACROSS
FLATS
TORQUE:
50 ft-lbs
(67.8 Nm)
max.
1.06
27.0
ACROSS FLATS
TORQUE:
10–12 ft-lbs
(14–16 Nm)
MANUAL
OVERRIDE
OPTION
"G"
MANUAL
OVERRIDE
OPTION
"M"
(continued)
PERFORMANCE
2010
PERCENT OF MAX. CONTROL CURRENT
FLOW lpm/gpm
40 5030 60 70 80 90 100
113.5/30
94.6/25
75.7/20
56.8/15
37.9/10
18.9/5
2-WAY VALVE
Regulated Flow vs. Current
240 bar/3500 psi Inlet
207 bar/3000 psi at Port
12V Coil; 110 Hz PWM
32 cSt/150 sus oil at 40°C
PRESSURE DROP bar/psi
FLOW lpm/gpm
172
2500
103
1500
242
3500
35
500
113.5/30
94.6/25
75.7/20
56.8/15
37.9/10
18.9/5
2-WAY VALVE
Regulated Flow vs. Pressure Drop
240 bar/3500 psi Inlet
12V Coil; 110 Hz PWM
32 cSt/150 sus oil at 40°C
1.60 amp
1.25 amp
1.0 amp
0.7 amp
0.4 amp
®
HYDRAFORCE
HYDRAFORCE
.com
®
Porting
0 Cartridge
Only
12T SAE 12
16T SAE 16
Option(s)
None
(Blank)
Manual
Override M
Manual
Override
with Guard G
Cartridge: Weight: 0.54 kg. (1.19 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces.
Buna N O-rings and polyester
elastomer back-ups standard.
Standard Ported Body: Weight:
1.6 kg. (3.35 lbs.) Anodized high-
strength 6061 T6 aluminum alloy,
rated to 207 bar (3000 psi). Ductile
iron bodies available; dimensions
may differ. See page 8.016.1
70-Size “D” Coil: Weight: 0.32 kg.
(0.7 lbs.) Unitized thermoplastic
encapsulated, Class H high
temperature magnet-wire.
See page 3.200.7.
70-Size “E” Coil: Weight: 0.41 kg.
(0.9 lbs.) Fully encapsulated with
rugged external metal shell.
IP69K rated. See page 3.400.13.
MATERIALS
TO ORDER
PV76-30A
__ - __ __ __ - __ - __ __ __ __
Voltage
0 Less Coil
12 12 VDC
24 24 VDC
Coils with internal diode are
available. Consult factory.
Seals
Buna N (Std.) N
Fluorocarbon V
Terminations D-Coil
DS Dual Spades
DG DIN 43650
DL Leadwires (2)
DL/W Leads w/Weatherpak
®
Connectors
Terminations E-Coil
IP69K Rated
ER Deutsch DT04-2P
EY Metri-Pack
®
150