DESCRIPTION
A high pressure, solenoid-operated, electrically-variable, three-port, pressure-
compensated, spool-type, normally closed when de-energized, proportional flow
control valve. It can be used as a priority-type flow regulator with pressure-compen-
sated, regulated and bypass flow. It can also be used as a restrictive-type 2-way,
pressure-compensated flow regulator when the bypass line (port 2) is blocked.
OPERATION
The HPV12-30 will regulate flow out of port 3 regardless of system working pressure.
With an increasing current applied to the solenoid, the HPV12-30 will increase output
flow.
Note: When used as a bypass flow control in applications where the priority flow port
will be blocked by external valving, bypass pressure drop will increase unless a small
amount of leakage is provided for the priority port. Consult factory.
FEATURES
Excellent linearity and hysteresis.
Hardened spool and cage for long life.
Optional coil voltages and terminations.
Efficient wet armature construction.
Cartridges voltage-interchangeable.
Unitized, molded coil design.
Coil waterproofing standard.
• All HyPerformance™ products are tested to the rigorous standards
of the NFPA specification T2.6.1.
• All HyPerformance™ valves are tested at a verification level of 90%
and an assurance of 99%.
RATINGS
Operating Pressure: 350 bar (5075 psi); 10% life cycle 420 bar (6090 psi)
Note: All HyPerformance™ products are tested for 900K cycles at 350 bar
and 100K cycles at 420 bar.
Proof Pressure: 690 bar (10,000 psi)
Burst Pressure: 1380 bar (20,000 psi)
Regulated Flow Rate: 76 lpm (20 gpm) nominal input; 114 lpm (30 gpm) maximum
input; priority type 66 lpm (17.5 gpm) maximum; restrictive type 60 lpm (16 gpm)
maximum.
Max. Internal Leakage: 380 ml/min. (0.10 gpm) at port 3 at 0 current with 350 bar
(5075 psi) at port 1 (port 2 blocked)
Temperature: -54°C - 107°C (-65°F - 225°F) with PPDI Urethane seals
Hysteresis: ±1.9 lpm (0.50 gpm) maximum
Dither/PWM Frequency Range: 100 to 250 Hz
Electrical Parameters (with size 10 E-series coil):
Coil
Voltage
12 VDC
24 VDC
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: HVC12-3; See page 9.112.1
Cavity Tool: HCT10-3X-XX; See page 8.600.1
Seal Kit: HSK12-3X-0; See page 8.650.1 for seal kit options
and appropriate seals based on application temperature range.
Coil Nut: Part No. 7004420
HPV12-30 HyPerformance™ Proportional Flow,
2
1
3
ISO SYMBOL
2.371.1
PERFORMANCE
200
Percent of Max. Control Current
FLOW lpm/gpm
Flow vs. Current
76 lpm (20 gpm) Input Flow with
350 bar (5075 psi) Inlet Relief at 1;
310 bar (4500 psi) Load Pressure at 3;
12V Coil; 110 Hz PWM
32 cSt/150 sus oil at 40°C (104°F)
400 600 800 1000
75.7/20
60.6/16
45.5/12
30.3/8
15.1/4
1200
2-Ported - - -
3-Ported
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROLS
Performance info. continued
on following page.
HYDRAFORCE
.com
®
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
Threshold
Current
250 ± 100 mA
125 ± 50 mA
Max. Control
Current
1100 ± 100 mA
550 ± 50 mA
Blue rectangles are links to other catalog pages.
HPV12-30Normally Closed, Priority Flow
DIMENSIONS
2.371.2
1.84
46.7
3.02
76.7
1.31
33.3
ACROSS
FLATS
0.75
19.1
ACROSS FLATS
TORQUE
115–125 ft-lbs
(156–170 Nm)
TORQUE
5–7 ft-lbs
(7–10 Nm)
COIL MUST
BE INSTALLED
WITH LETTERING UP
ORIFICE DISC
CANNOT BE USED
WITH THIS PRODUCT
INCH
MILLIMETRE
2.88
73.2
1.62
41.1
E-Coil
View
53.8
82.6
101.6
29.2
8.6
91.9
4.8
101.6
50.8
63.5
1.15
3.62
0.19
4.00
3.25
2.12
4.00
2.00
2.50
0.34
2
3
1
2
1
3
DIA.
Ductile Iron
Body Shown
E-Coil
View
PERFORMANCE
(Continued)
69
1000
PRESSURE DROP bar/psi
FLOW lpm/gpm
Regulated Flow vs. Pressure Drop
2-Ported; Flow Range A
240 bar/3500 psi Inlet
12V Coil; 110 Hz PWM
32 cSt/150 sus oil at 40°C
138
2000
207
3000
345
5000
276
4000
75.7/20
60.6/16
45.4/12
30.3/8
15.1/4
1100 mA
800 mA
600 mA
400 mA
69
1000
69
1000
0
PRESSURE DROP bar/psi
FLOW lpm/gpm
138
2000
138
2000
207
3000
207
3000
276
4000
276
4000
345
5000
345
5000
61/16
15/4
45/12
76/20
30/8
1100 mA
800 mA
600 mA
400 mA400 mA
600 mA
800 mA
1100 mA
Bypass Higher than Priority Priority Higher than Bypass
Priority Flow vs. Load
3-Ported; 76 lpm (20 gpm) Input Flow
with 350 bar/5075 psi Inlet Relief at Port 1;
12V Coil; 110 Hz PWM; 32 cSt/150 sus oil at 40°C
®
HYDRAFORCE
HYDRAFORCE
.com
®
Cartridge: Weight (without coil and
nut): 0.32 kg. (0.70 lbs.) Steel with
hardened work surfaces. PPDI
urethane seals without back-up rings
standard.
Standard Ported Body: Weight: 4.0 kg
(8.93 lbs.) HyPerformance™ Ductile
iron (Code 'D') standard. Rated to
345 bar (5000 psi).
See page 8.012.1.
E-Coil: Weight: 0.41 kg. (0.9 lbs.) Fully
encapsulated with rugged external
metal shell. IP69K rated.
See page 3.400.1.
MATERIALS
TO ORDER
HPV12-30
- __ __ __ - __ - __ __ __ __
Voltage
0 Less Coil
12 12 VDC
24 24 VDC
Coils with internal diode are available.
Consult factory.
See coil option info. on page 3.400.1
Seals
PPDI Urethane U
Coil Terminations
IP69K Rated
Deutsch DT04-2P ER
Metri-Pack
®
150 EY
Dual Leads EL
Note: PPDI Urethane seals are recommended
for pressures over 241 bar (3500 psi).
Note: Consult factory for additional seal
options.
Porting
Cartridge Only 0
SAE 08 08TD
SAE 10 10TD
SAE 12 12TD
1/2" BSP* 4BD
3/4" BSP* 6BD
*BSP body; UK Mfg only
Blue rectangles are links to other catalog pages.