DESCRIPTION
A high pressure, solenoid-operated, electrically-variable, three-port, pressure-
compensated, spool-type, normally closed when de-energized, proportional flow
control valve. It can be used as a priority-type flow regulator with pressure-compen-
sated, regulated and bypass flow. It can also be used as a restrictive-type 2-way,
pressure-compensated flow regulator when the bypass line (port 2) is blocked.
OPERATION
The HPV12-30 will regulate flow out of port 3 regardless of system working pressure.
With an increasing current applied to the solenoid, the HPV12-30 will increase output
flow.
Note: When used as a bypass flow control in applications where the priority flow port
will be blocked by external valving, bypass pressure drop will increase unless a small
amount of leakage is provided for the priority port. Consult factory.
FEATURES
• Excellent linearity and hysteresis.
• Hardened spool and cage for long life.
• Optional coil voltages and terminations.
• Efficient wet armature construction.
• Cartridges voltage-interchangeable.
• Unitized, molded coil design.
• Coil waterproofing standard.
• All HyPerformance™ products are tested to the rigorous standards
of the NFPA specification T2.6.1.
• All HyPerformance™ valves are tested at a verification level of 90%
and an assurance of 99%.
RATINGS
Operating Pressure: 350 bar (5075 psi); 10% life cycle 420 bar (6090 psi)
Note: All HyPerformance™ products are tested for 900K cycles at 350 bar
and 100K cycles at 420 bar.
Proof Pressure: 690 bar (10,000 psi)
Burst Pressure: 1380 bar (20,000 psi)
Regulated Flow Rate: 76 lpm (20 gpm) nominal input; 114 lpm (30 gpm) maximum
input; priority type 66 lpm (17.5 gpm) maximum; restrictive type 60 lpm (16 gpm)
maximum.
Max. Internal Leakage: 380 ml/min. (0.10 gpm) at port 3 at 0 current with 350 bar
(5075 psi) at port 1 (port 2 blocked)
Temperature: -54°C - 107°C (-65°F - 225°F) with PPDI Urethane seals
Hysteresis: ±1.9 lpm (0.50 gpm) maximum
Dither/PWM Frequency Range: 100 to 250 Hz
Electrical Parameters (with size 10 E-series coil):
Coil
Voltage
12 VDC
24 VDC
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: HVC12-3; See page 9.112.1
Cavity Tool: HCT10-3X-XX; See page 8.600.1
Seal Kit: HSK12-3X-0; See page 8.650.1 for seal kit options
and appropriate seals based on application temperature range.
Coil Nut: Part No. 7004420
HPV12-30 HyPerformance™ Proportional Flow,
2
1
3
ISO SYMBOL
2.371.1
PERFORMANCE
200
Percent of Max. Control Current
FLOW lpm/gpm
Flow vs. Current
76 lpm (20 gpm) Input Flow with
350 bar (5075 psi) Inlet Relief at 1;
310 bar (4500 psi) Load Pressure at 3;
12V Coil; 110 Hz PWM
32 cSt/150 sus oil at 40°C (104°F)
400 600 800 1000
75.7/20
60.6/16
45.5/12
30.3/8
15.1/4
1200
2-Ported - - -
3-Ported
—
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROLS
Performance info. continued
on following page.
HYDRAFORCE
.com
®
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
Threshold
Current
250 ± 100 mA
125 ± 50 mA
Max. Control
Current
1100 ± 100 mA
550 ± 50 mA