DESCRIPTION
A solenoid-operated, electrically-variable, three-port, pressure-compensated, spool-
type, normally closed when de-energized, proportional flow control valve. It can be
used as a priority-type flow regulator with pressure-compensated, regulated and
bypass flow. It can also be used as a restrictive-type 2-way, pressure-compensated
flow regulator when the bypass line (port 2) is blocked.
OPERATION
The PV08-30 will regulate flow out of port 3 regardless of system working pressure.
With an increasing current applied to the solenoid, the PV08-30 will increase output
flow.
Note: When used as a bypass flow control in applications where the priority flow port
will be blocked by external valving (dead-headed), a small bleed orifice is required at
the priority port (port 3). Consult factory.
FEATURES
Excellent linearity and hysteresis characteristics.
Hardened spool and cage for long life.
Optional coil voltages and terminations.
Efficient wet armature construction.
RATINGS
Operating Pressure: Inlet: 240 bar (3500 psi); Ports 2 and 3: 207 bar (3000 psi)
Regulated Flow Rate: Bypass Blocked, Range A: 11.4 lpm (3.0 gpm)
Bypass Blocked, Range B: 5.7 lpm (1.5 gpm)
Bypass Open, Range A: 11.4 lpm (3.0 gpm)
Bypass Open, Range B: 5.7 lpm (1.5 gpm)
Nominal Input Flow: Bypass Open, Range A: 15.2 lpm (4.0 gpm)
Bypass Open, Range B: 7.6 lpm (2.0 gpm)
Maximum Input Flow: Bypass Open, Range A: 22.8 lpm (6.0 gpm)
Bypass Open, Range B: 22.8 lpm (6.0 gpm)
Internal Leakage: 100 cc/min. (6 cu. in./min.) fully closed at 207 bar (3000 psi)
Electrical: 2 standard voltage ratings (Uses EHPR Series Coil; See page 3.200.1)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: VC08-3; See page 9.108.1; Cavity Tool: CT08-3X-XX; See page 8.600.1
Seal Kit: SK08-3X-MM; See page 8.650.1 for seal kit options
and appropriate seals based on application temperature range.
PV08-30 Proportional Flow Control Cartridge,
USASI/ISO:
SYMBOLS
2.370.1
PERFORMANCE
Threshold Current
400 ± 100 mA
200 ± 50 mA
Coil Voltage
12 VDC
24 VDC
Max. Control Current
1400 ± 150 mA
700 ± 75 mA
2
3
1
20
PERCENT OF MAX. CONTROL CURRENT
FLOW lpm/gpm
Nominal Flow vs. Current
207 bar/3000 psi; 12V Coil; 100 Hz PWM
32 cSt/150 sus oil at 40°C
40 60 80 100
15.2/4
11.4/3
7.6/2
3.8/1
Range A, 2-Ported or 3-Ported
Range B, 2-Ported or 3-Ported
2-Ported:
69
1000
PRESSURE DROP bar/psi
FLOW lpm/gpm
Regulated Flow vs. Pressure Drop
2-Ported; Flow Range A
240 bar/3500 psi Inlet
12V Coil; 100 Hz PWM
32 cSt/150 sus oil at 40çC
138
2000
207
3000
276
4000
15.2/4
11.4/3
7.6/2
3.8/1
1.5 AMP
1.1 AMP
0.8 AMP
0.4 AMP
69
1000
PRESSURE DROP bar/psi
FLOW lpm/gpm
Regulated Flow vs. Pressure Drop
2-Ported; Flow Range B
240 bar/3500 psi Inlet
12V Coil; 100 Hz PWM
32 cSt/150 sus oil at 40çC
138
2000
207
3000
276
4000
3.8/1
7.6/2
1.50 AMP
1.10 AMP
0.80 AMP
0.40 AMP
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROLS
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
Cartridge: Weight: 0.13 kg. (0.28 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces. Buna
N O-rings and polyester elastomer
back-ups standard.
Standard Ported Body: Weight:
0.27 kg. (0.60 lbs.) Anodized high-
strength 6061 T6 aluminum alloy,
rated to 207 bar (3000 psi). Ductile
iron bodies available; dimensions
may differ. See page 8.008.1
EHPR Series Coil: Weight: 0.32 kg.
(0.7 lbs.) Unitized thermoplastic
encapsulated, Class H high
temperature magnet-wire.
See page 3.200.1.
DIMENSIONS
MATERIALS
TO ORDER
PV08-30
2.370.2
PV08-30__ __ - __ __ __ - __ - __ __ __ __
Flow Range
A
B
Voltage
0 Less Coil
12 12 VDC
24 24 VDC
(Required. See
Performance Curves)
Normally Closed
1.19
30.2
Manual
Override ‘G’
with Guard
TORQUE:
5 ft-lbs/7 Nm
Manual
Override ‘M’
MILLIMETRE
INCH
15.2
0.60
53.8
2.12
66.5
2.62
50.8
2.00
29.7
1.17
6.4
0.25
7.1
0.28
83.2
3.27
40.6
1.60
28.7
1.13
31.8
1.25
63.5
2.50
2
2
3
3
1
1
0.88
22.1
ACROSS FLATS
TORQUE: 4–5 ft-lbs
(7–10 Nm)
0.88
22.1
ACROSS FLATS
TORQUE:
(27.1 Nm)
20 ft-lbs
90.0
3.55
Terminations
DS Dual Spades
DG DIN 43650
DL Leadwires (2)
DL/W Leads w/Weatherpak
Connectors
Coils with internal diode are
available. Consult factory.
Seals
Buna N (Std.) N
Fluorocarbon V
®
HYDRAFORCE
HYDRAFORCE
.com
®
Porting
Cartridge Only 0
SAE 6 6T
3/8 in. BSP* 3B
*BSP Body; U.K. Mfr. Only
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
Option
None
(Blank)
Manual Override M
Manual Override
with Guard G