DESCRIPTION
A solenoid-operated, 5-way, 3-position, proportional, screw-in, motor-spool-type
hydraulic cartridge valve with integral load sense port.
OPERATION
When de-energized, the SP08-58D allows flow between 4, 3, 2, and 1. When coil #1
is energized, flow is allowed from 5 to 2, and from 4 to 3. When coil #2 is energized,
flow is allowed from 5 to 4, and from 2 to 3. Load sense is connected to port 5 when
the spool is in shifted positions.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
• Continuous-duty rated solenoid. • Unitized, molded coil design.
• Hardened precision spool and cage for long life.
• Optional coil voltages and terminations.
• Optional waterproof E-Coils rated up to IP69K.
• Compact size; Manual override options.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
RATINGS
Operating Pressure: 241 bar (3500 psi)
Proof Pressure: 345 bar (5000 psi)
Flow: 15.1 lpm (4.0 gpm) maximum; see performance charts
Internal Leakage: 246 cc/minute (15 cu. in./minute) max. at 207 bar (3000 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20° C: Standard Coil: 1.2 amps at 12 VDC;
0.13 amps at 115 VAC (full wave rectified).
E-Coil: 1.4 amps at 12 VDC; 0.7 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-5; See page 9.108.1; Cavity Tool: CT08-5XX; See page 8.600.1
Seal Kit: SK08-5X-MMM; See page 8.650.1
Coil Nut: Part No. 7004400
Coil Spacer: Std D-Coil Spacer Part No. 7012940; E-Coil Spacer Part No. 4534720;
If cartridge is ordered "Less Coil," D-Coil spacer will be provided unless an E is
specified in the Coil Termination To Order section.
SP08-58D Spool, 5-Way, 3-Position . . .
SYMBOL
2.145.1
PERFORMANCE (Cartridge Only)
HYDRAFORCE
.com
®
41.4/600
34.5/500
27.6/400
20.7/300
13.8/200
6.9/100
FLOW lpm/gpm
PRESSURE bar/psi
Pressure Drop
32 cSt/150 sus oil at 40qC
0.19
0.05
0.38
0.10
0.57
0.15
0.76
0.20
1 to 3 Neutral
34.5/500
31.0/450
27.6/400
24.1/350
20.7/300
17.2/250
13.8/200
10.3/150
6.9/100
3.4/50
FLOW lpm/gpm
PRESSURE bar/psi
Pressure Drop vs. Flow
at I-Max. with No Load
32 cSt/150 sus oil at 40°C
1.9
0.5
3.8
1.0
5.7
1.5
7.6
2.0
9.5
2.5
11.4
3.0
13.3
3.5
15.1
4.0
5 to 4
5 to 2
4 to 3
2 to 3
4.5/1.2
6.1/1.6
3.0/0.8
1.5/0.4
7.6/2.0
0
0.4 0.8 1.00.60.81.0 0.2 0.2 0.4 0.60
AMPERAGE with 100 Hz PWM Dither <10%
FLOW lpm/gpm
Coil S2
Typical Performance at 34.5 bar/500 psi Load
and 10.3 bar/150 psi Compensator
Shaded Areas = Range
Coil S1
Performance info. continued on following page.
ELECTRO-PROPORTIONAL VALVES—DIRECTIONAL CONTROL
Blue rectangles are links to other catalog pages.