DESCRIPTION
A solenoid-operated, 5-way, 3-position, proportional, screw-in hydraulic cartridge
valve with integral brake release port.
OPERATION
When de-energized, the SP10-58C allows flow between 3 and 1. When coil #1 is en-
ergized, flow is allowed from 5 to 2, and from 4 to 3. When coil #2 is energized, flow
is allowed from 5 to 4, and from 2 to 3. Load sense is connected to port 5 when the
spool is in shifted positions.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and
Coil Operating Parameters,” page 2.002.1.
FEATURES
• Continuous-duty rated solenoid.
• Hardened precision spool and cage for long life.
• Optional coil voltages and terminations
• Cartridges are voltage interchangeable.
• Optional manual override.
• Optional waterproof E-Coils rated up to IP69K.
RATINGS
Operating Pressure: 250 bar (3625 psi) with standard Buna N seals
Flow: 22.7 lpm (6 gpm) max. See performance chart
Internal Leakage: 246 cc/minute (15 cu. in./minute) max. at 207 bar (3000 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-5; See page 9.110.1; Cavity Tool: CT10-5XX; See page 8.600.1
Seal Kit: SK10-5X-MMMM; See page 8.650.1
Coil Nut: Part No. 7004400
Coil Spacer: Std. D-Coil Spacer Part No. 7000280; E-Coil Spacer Part No. 4539700;
If cartridge is ordered "Less Coil," D-Coil spacer will be provided unless an E is
specified in the Coil Termination To Order section.
SYMBOLS
2.142.1
USASI:
ISO:
PERFORMANCE (Cartridge Only)
ELECTRO-PROPORTIONAL VALVES—DIRECTIONAL CONTROL
15.1/4
18.9/5
30.3/8
7.5/2
3.8/1
11.4/3
22.7/6
26.5/7
0
0.81.0 0.6 0.8 1.21.2 0.4 0.2 0.40.2 0.6 1.00
AMPERAGE with 100 Hz Dither
FLOW lpm/gpm
Bottom Coil
Performance with 12 VDC Coils
and 10.3 bar/150 psi inline compensator
(for other voltages consult factory)
Top Coil
Performance information continued on following page.
17.2/250
15.5/225
13.8/200
12.1/175
10.3/150
8.6/125
6.9/100
3.4/50
5.2/75
1.7/25
3.8
1
7.6
2
11.4
3
15.1
4
18.9
5
22.7
6
FLOW lpm/gpm
PRESSURE bar/psi
32 cSt/150 sus oil at 40°C
4 to 3 or 2 to 3 at 100% current, S1 or S2 energized:
————
5 to 2 or 5 to 4 at 100% current, S1 or S2 energized: - - - - - - -
SP10-58C Spool, 5-Way, 3-Position . . .
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.