DESCRIPTION
A solenoid-operated, five-way, three-position, proportional, screw-in hydraulic
cartridge valve with integral load-sense port.
OPERATION
When de-energized, the SP08-57D blocks flow at 5 while allowing flow from both 2
and 4 to 3. When coil #1 is energized, flow is allowed from 5 to 2, and from 4 to 3.
When coil #2 is energized, flow is allowed from 5 to 4, and from 2 to 3. Load sense is
connected to port 5 when the spool is in shifted positions.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
• Continuous-duty rated solenoid.
• Hardened precision spool and cage for long life.
• Optional coil voltages and terminations
• Cartridges are voltage interchangeable.
• Compact size; Manual override options.
• Optional waterproof E-Coils rated up to IP69K.
RATINGS
Operating Pressure: 241 bar (3500 psi) with standard Buna N seals
Flow: 9.5 lpm (2.5 gpm); see performance charts
Internal Leakage: 164 cc/minute (10 cu. in./minute) max. at 207 bar (3000 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20° C: Standard Coil: 1.2 amps at 12 VDC;
0.13 amps at 115 VAC (full wave rectified).
E-Coil: 1.4 amps at 12 VDC; 0.7 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-5; See page 9.108.1; Cavity Tool: CT08-5XX; See page 8.600.1
Seal Kit: SK08-5X-MMM; See page 8.650.1
Coil Nut: Part No. 7004400
Coil Spacer: Std D-Coil Spacer Part No. 7012940; E-Coil Spacer Part No. 4534720;
If cartridge is ordered "Less Coil," D-Coil spacer will be provided unless an E is
specified in the Coil Termination To Order section.
SYMBOL
2.134.1
PERFORMANCE (Cartridge Only)
ELECTRO-PROPORTIONAL VALVES—DIRECTIONAL CONTROL
Performance information continued
on following page.
SP08-57D Spool, 5-Way, 3-Position . . .
HYDRAFORCE
.com
®
9.5/2.5
7.6/2.0
5.7/1.5
3.8/1.0
1.9/0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
CURRENT amps
FLOW lpm/gpm
32 cSt/150 sus oil at 40°C
Flow vs. Current
Typical Performance
Coil S1
Coil S2
34.5/500
31.0/450
27.6/400
24.1/350
20.7/300
17.2/250
13.8/200
10.3/150
6.9/100
3.4/50
FLOW lpm/gpm
PRESSURE DROP bar/psi
Differential Pressure vs. Flow
at I-Max. with No Load; Port 5 to 3
32 cSt/150 sus oil at 40qC
1.9
0.5
3.8
1.0
5.7
1.5
7.6
2.0
9.5
2.5
11.4
3.0
13.3
3.5
15.1
4.0
5 to 4
5 to 2
4 to 3
2 to 3
Blue rectangles are links to other catalog pages.