DESCRIPTION
A solenoid-operated, normally-closed, proportional, poppet-type screw-in hydraulic
cartridge valve providing an integral, non-isolated load signal to pilot counterbalance
or other control valves in bridge circuit applications.
OPERATION
When de-energized, the SPCL10-32 blocks flow at 1 and 3, while allowing the port 2
load signal to bleed to the low-pressure side of the circuit. When energized,
proportionally-controlled flow is allowed from 3 to 1 with a load signal supplied at 2.
Reverse flow is not allowed from 1 to 3.
Note: When using this valve in bridge circuits, seals should not be used on the pilot
pistons of the pilot-operated check valves. This is to avoid trapping oil which would
keep the pilot-operated check valve open.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
Industry-common cavity. Efficient wet-armature construction.
Continuous-duty rated coils. Optional waterproof E-Coils rated up to IP69K.
Reduce manifold space claim.
RATINGS
Operating Pressure: 250 bar (3625 psi); Holding Pressure at 1: 350 bar (5000 psi)
Internal Leakage: Ports 1 and 3: 5 drops/minute max. at 250 bar (3625 psi)
Operating Fluid Temperature: -40 to 121°C with Buna N seals;
-35 to 204°C with Fluorocarbon seals; -54 to 107°C with Polyurethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard D-Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Installation: No restrictions; See page 9.020.1; Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Cavity: VC10-3, Variation “B”; See page 9.110.1
Cavity Tool: CT10-3XX; See page 8.600.1
Seal Kit: SK10-3X-MM; See page 8.650.1
Coil Nut: Part No. 7004400
SPCL10-32 Poppet, 3-Port, Normally Closed
SYMBOL
2.042.1
PERFORMANCE (Cartridge Only)
HYDRAFORCE
.com
®
ELECTRO-PROPORTIONAL VALVES—DIRECTIONAL CONTROL
7.6/2
15.1/4
22.7/6
30.3/8
68.1/18
60.6/16
53.0/14
45.4/12
37.9/10
75.7/20
0.1 0.2
30 40 50 60 70 80 90 100
0.40.3 0.5 0.8 0.9 1.0 1.1 1.20.6 0.7
Amps:
% of Max. Control Current:
FLOW lpm/gpm
FLOW vs. CURRENT
16 bar/230 psi – – –; 35 bar/500 psi ——
Ranges Shaded
18.9/5
37.9/10
56.8/15
75.7/20
170.3/45
151.4/40
132.5/35
113.6/30
94.6/25
189.2/50
0.1 0.2
30 40 50 60 70 80 90 100
0.40.3 0.5 0.8 0.9 1.0 1.1 1.20.6 0.7
Amps:
% of Max. Control Current:
FLOW lpm/gpm
FLOW vs. CURRENT
103 bar/1500 psi – – –; 206 bar/3000 psi ——
Ranges Shaded
ISO:
Expanded:
U.S. Patent
7,921,880
Blue rectangles are links to other catalog pages.
DIMENSIONS
SPCL10-32
2.042.2
TO ORDER
Cartridge: Weight: 0.18 kg.
(0.40 lbs.); Steel with hardened
work surfaces. Zinc-plated
exposed surfaces. Buna N
O-rings and polyester elastomer
back-up standard.
Standard D-Coil: Weight: 0.27 kg.
(0.60 lbs.); Unitized thermoplas-
tic encapsulated, Class H high
temperature magnetwire. See
page 3.200.1.
E-Coil: Weight: 0.41 kg. (0.9 lbs.);
Fully encapsulated with rugged
external metal shell. Rated up to
IP69K with integral connectors.
Note: See page 3.400.1 for all
E-Coil retrofit applications.
MATERIALS
®
HYDRAFORCE
HYDRAFORCE
.com
®
1.00
25.4
1.62
41.1
1.84
DIA.
46.7
E-Coil
View
3.50
TORQUE
24–26 ft-lbs
(32.5–35.3 Nm)
88.9
0.87
22.1
1.48
37.6
2.32
59.0
D-Coil
View
TORQUE
5 – 7 ft-lb.
(6.8 Nm max.)
Manual
Override
J
Manual
Override M, or Y
to ~
0.5A - - - - - ; 0.75A – – – –
1.0A — — —; 1.2A ——
32 cSt/150 sus oil at 40°C
241/3500
138/2000
172/2500
207/3000
103/1500
69/1000
34.5/500
22.7
6
45.4
12
56.8
15
FLOW lpm/gpm
PRESSURE DROP bar/psi
11.4
3
34.1
9
to at 1.2A Current
32 cSt/150 sus oil at 40°C
0.83/12
0.62/9
0.41/6
0.21/3
0.76
0.2
1.52
0.4
1.90
0.5
FLOW lpm/gpm
PRESSURE DROP bar/psi
0.38
0.1
1.14
0.3
PERFORMANCE
(Continued)
U.S. Patent 7,921,880
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
SPCL10-32__ - __ __ __ - __ - __ __ __ __ __
Porting
Cartridge Only 0
Seals
Buna N (Std.) N
Fluorocarbon V
Polyurethane P
Voltage
0 Less Coil**
12 12 VDC
20 20 VDC
24 24 VDC
**Includes D-Coil Nut
For Coils with Zener Diode, add “/Z” to option code.
For example: “ER/Z”. Not available on all models.
See coil option info. on pages 3.200.1 & 3.400.1
Coil Termination E-Coil D-Coil
Deutsch DT04-2P ER (IP69K) DR (IP65)
Metri-Pack
®
150 EY (IP69K) DY (IP65)
Dual Lead Wires EL (IP69K) DL (IP65)
Amp Jr. Timer EJ (IP67)
DIN 43650 EG (IP65) DG (IP65)
Dual Spades DS (IP65)
Option
None (Blank)
Manual Override M
Manual Override Y
Manual Override J
For Manual Override details
see page 1.001.1
Note: Flow performance varies
with manual override options.
Consult factory for details.
Blue rectangles are links to other catalog pages.