DESCRIPTION
A solenoid-operated, normally-closed, proportional, poppet-type, screw-in hydraulic
cartridge valve incorporating an integral load-sense pressure port with isolation check.
OPERATION
When de-energized, the SPCL10-30 blocks flow at all ports. When energized,
proportionally-regulated flow is allowed from
3 to 1 with a check-isolated
load-sense signal supplied at 2. Reverse flow is not allowed from 1 to 3.
Note: When using this valve in bridge circuits, seals should not be used on the pilot
pistons of the pilot-operated check valves. This is to avoid trapping oil which would
keep the pilot-operated check valve open.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and
Coil Operating Parameters,” page 2.002.1.
FEATURES
• Industry-common cavity. • Efficient wet-armature construction.
• Continuous-duty rated coils. • Optional waterproof E-Coils rated up to IP69K.
• Reduce manifold space claim.
RATINGS
Operating Pressure: 250 bar (3625 psi); Holding Pressure at 1: 350 bar (5000 psi)
Internal Leakage: Ports 1 and 3: 5 drops/minute max. at 250 bar (3625 psi)
Port 2: 10 drops/minute max. at 250 bar (3625 psi)
Operating Temperature: -40° to 100°C (-40° to 212° F) with standard Buna N seals;
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals;
-54°C to 107°C (-65°F to 225°F) with Polyurethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard D-Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Installation: No restrictions; See page 9.020.1; Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Cavity: VC10-3, Variation “B”; See page 9.110.1
Cavity Tool: CT10-3xx; See page 8.600.1
Seal Kit: SK10-3X-MM; See page 8.650.1
Coil Nut: Part No. 7004400
SPCL10-30 Poppet, 3-Port, Normally Closed
SYMBOL
2.040.1
PERFORMANCE (Cartridge Only)
HYDRAFORCE
.com
®
ELECTRO-PROPORTIONAL VALVES—DIRECTIONAL CONTROL
ISO:
Expanded:
7.6/2
15.1/4
22.7/6
30.3/8
68.1/18
60.6/16
53.0/14
45.4/12
37.9/10
75.7/20
0.1 0.2
30 40 50 60 70 80 90 100
0.40.3 0.5 0.8 0.9 1.0 1.1 1.20.6 0.7
Amps:
% of Max. Control Current:
FLOW lpm/gpm
FLOW vs. CURRENT
16 bar/230 psi – – –; 35 bar/500 psi ——
Ranges Shaded
18.9/5
37.9/10
56.8/15
75.7/20
170.3/45
151.4/40
132.5/35
113.6/30
94.6/25
189.2/50
0.1 0.2
30 40 50 60 70 80 90 100
0.40.3 0.5 0.8 0.9 1.0 1.1 1.20.6 0.7
Amps:
% of Max. Control Current:
FLOW lpm/gpm
FLOW vs. CURRENT
103 bar/1500 psi – – –; 206 bar/3000 psi ——
Ranges Shaded
U.S. Patent
7,921,880
Blue rectangles are links to other catalog pages.