DESCRIPTION
A proportional solenoid-operated, 2-way, spool-type, normally-closed, direct-acting,
screw-in hydraulic cartridge valve for bi-directional metering.
OPERATION
When energized, the SP10-24 acts as a bi-directional metering valve.
When de-energized, the valve blocks flow in both directions.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
• Industry-common cavity. • Efficient wet-armature construction.
• Continuous-duty rated coils. • Optional waterproof E-Coils rated up to IP69K.
• Manual Override option.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Minimum Operating Dither/Pulse Frequency: 70 Hz
Flow: 0 to 26.5 lpm (0 to 7 gpm)
Max. Internal Leakage: 328 cc/minute (20 cu. in./minute) at 207 bar (3000 psi)
Operating Temperature: -40 to 100°C (-40° to 212°F) with standard Buna N seals
-26 to 204°C (-15°F to 400°F) with Fluorocarbon seals
-54 to 107°C (-65°F to 225°F) with Polyurethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No Restrictions. See page 9.020.1
Cavity: VC10-2; See page 9.110.1;
Cavity Tool: CT10-2XX; See page 8.600.1
Seal Kit: SK10-2X-M; See page 8.650.1
Coil Nut: Part No. 7004420
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROL
SP10-24 Spool, 2-Way, Normally Closed, Metering
SYMBOL
2.027.1
PERFORMANCE
HYDRAFORCE
.com
®
Performance
charts
continued
on next page.
3.8/1.0
7.6/2.0
11.4/3.0
22.7/6.0
18.9/5.0
15.1/4.0
0.1 0.2 0.40.3 0.5 0.8 0.9 1.0 1.1 1.20.6 0.7
Amps:
40302010 70 80 90 10050 60
% of Max.
Control Current:
FLOW lpm/gpm
Typical Flow vs. Current
at 11 bar (160 psi) with 12 VDC Coil
Shaded Area = Range
1.9/0.5
3.8/1.0
5.7/1.5
7.6/2.0
15.1/4.0
13.3/3.5
11.4/3.0
9.5/2.5
0.1 0.2 0.40.3 0.5 0.8 0.9 1.0 1.1 1.20.6 0.7
Amps:
FLOW lpm/gpm
Typical Flow vs. Current
at 207 bar (3000 psi) with 12 VDC Coil
Shaded Area = Range
40302010 70 80 90 10050 60
% of Max.
Control Current:
1.7/25
3.4/50
5.2/75
6.9/100
8.6/125
10.3/150
7.6
2
3.9
1
15.1
4
11.4
3
18.9
5
22.7
6
26.5
7
FLOW lpm/gpm
PRESSURE bar/psi
Pressure Drop at I-Max.
2 to 1
1 to 2
Blue rectangles are links to other catalog pages.