DESCRIPTION
A proportional solenoid-operated, 2-way, bi-directional, poppet-type, normally closed,
screw-in hydraulic cartridge valve for low-leakage blocking and load-holding.
OPERATION
When de-energized, the SP08-22 acts as a check valve, allowing flow from 1 to 2,
while blocking flow from 2 to 1. When energized, the poppet lifts to open the 2 to 1
flow path. Flow is proportional to current applied to the coil. The reverse-flow check
allows unrestricted flow from 1 to 2
when the valve is energized, but this flow is not
proportional to the current.
Note: External circuitry is required to ramp current.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
Industry-common cavity. Hardened steel work surfaces.
Continuous-duty rated coils. Optional waterproof E-Coils rated up to IP69K
RATINGS
Operating Pressure: 207 bar (3000 psi)
Flow: 30.3 lpm (8 gpm) nominal
Max. Internal Leakage: 5 drops per minute at 207 bar (3000 psi)
Temperature: -40 to 100°C with standard Buna seals
Filtration: Recommend ISO 4406 16/13; See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No Restrictions. See page 9.020.1
Cavity: VC08-2; See page 9.108.1; Cavity Tool: CT08-2XX; See page 8.600.1
Seal Kit: SK08-2X-M; See page 8.650.1
Coil Nut: Part No. 7004400; For E-coils manuf. prior to 1-1-04, see page 3.400.1
SP08-22 Poppet, 2-Way, Normally Closed
SYMBOLS
USASI/ISO:
2.024.1
PERFORMANCE
FLOW lpm/gpm
49.2/13.0
45.4/12.0
41.6/11.0
37.9/10.0
34.1/9.0
30.3/8.0
26.5/7.0
22.7/6.0
18.9/5.0
15.2/4.0
11.4/3.0
7.6/2.0
3.8/1.0
0
FLOW vs. CURRENT at Various Differential Pressures
for Standard Coils (consult factory for E-Coils)
32 cSt/150 sus oil at 40C
PERCENT of MAX. CONTROL CURRENT
AMP (10 Volt Coil) 100 Hz Dither
10 20 30 40 50 60 70 80 90 100
0.12 0.23 0.35 0.46 0.58 0.69 0.81 0.92 1.04 1.15
207 bar
3000 psi
104 bar
1500 psi
35 bar
500 psi
10 bar
150 psi
8 gpm Nominal Flow Rating
11.4
3
22.7
6
34.1
9
45.2
12
56.8
15
FLOW lpm/gpm
35/500
69/1000
103/1500
138/2000
172/2500
207/3000
PRESSURE bar/psi
0.5 amp
0.65 amp
0.85 amp
1.0 amp
TYPICAL PRESSURE RESPONSE
12 VDC Coil
3.4/50
6.9/100
10.3/150
13.8/200
17.2/250
20.7/300
7.6
2
3.8
1
11.4
3
15.1
4
18.9
5
22.7
6
26.5
7
FLOW lpm/gpm
PRESSURE bar/psi
TYPICAL PRESSURE DROP 2 to 1
with 12 VDC Coil
1.0 amp
1.3 amp
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROL
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
SP08-22
2.024.2
DIMENSIONS
1.40
35.6
1.91
TORQUE
4–5 ft-lbs
(5.4–6.8 Nm)
max.
TORQUE
19–21 ft-lbs
(25.8–28.5 Nm)
48.5
1.91
48.5
1.41
DIA.
35.8
0.75
ACROSS
19.1
Standard
Coil View
E-Coil
View
FLATS
SCREEN
STANDARD
152μ
MATERIALS
Cartridge: Weight: 0.10 kg.
(0.23 lbs.) Steel with hardened
work surfaces. Zinc-plated
exposed surfaces. Buna N
O-rings and back-ups standard.
Standard Ported Body: Weight:
0.16 kg. (0.35 lbs.) Anodized
high-strength 6061 T6 aluminum
alloy, rated to 240 bar (3500 psi).
Ductile iron bodies available;
dimensions may differ.
See page 8.008.1
Standard Coil: Weight: 0.11 kg.
(0.25 lbs.) Unitized thermoplas-
tic encapsulated, Class H high
temperature magnetwire. See
page 3.200.1
E-Coil: Weight: 0.14 kg. (0.3 lbs.)
Perfect wound, fully encapsu-
lated with rugged external metal
shell. Rated up to IP69K with
integral connectors. Note: See
page 3.400.1 for all E-Coil
retrofi t applications.
SP08-22__ - __ __ __ - __ - __ __ __ __ __
TO ORDER
Porting
Cartridge Only 0
SAE 4 4T
SAE 6 6T
1/4 in. BSP* 2B
3/8 in. BSP* 3B
*BSP Body; U.K. Mfr. Only
Termination (VDC)
Std. Coil
DS Dual Spades
DG DIN 43650
DL Leadwires (2)
DL/W Leads w/Weatherpak
®
Connectors
DR Deutsch DT04-2P
Termination (VDC)
E-Coil
ER Deutsch DT04-2P
(IP69K Rated)
EY Metri-Pack
® 150.2A
(IP69K Rated)
PERCENT I-MAX. vs. TEMPERATURE
for 10 or 20 VDC Coil (for 10V Coil I-Max. = 1.15A)
78
80
82
84
86
88
90
92
94
96
98
100
102
-4
-20
32
0
68
20
104
40
140
60
176
80
PERCENT of I-MAX.
TEMPERATURE (°F/°C)
Curves show percent of nominal system voltage
minus 1.5V drop across controller
100%
85%
115%
PERFORMANCE (cont’d.)
Coils with internal diode are
available. Consult factory.
Option
None
(Blank)
Seals
N Buna N (Std.)
V Fluorocarbon
P Polyurethane
®
HYDRAFORCE
HYDRAFORCE
.com
®
Voltage
0 Less Coil**
10 10 VDC
12 12 VDC
20 20 VDC
24 24 VDC
**Includes Coil Nut
10 VDC and 20 VDC
coils should be used
for most continuous-
duty applications.
Consult factory.
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
Blue rectangles are links to other catalog pages.