DESCRIPTION
A proportional solenoid-operated, 2-way, piloted, poppet-type, normally open, screw-
in hydraulic cartridge valve for low-leakage blocking in high pressure load-holding
applications requiring low internal leakage.
OPERATION
When de-energized, the HSP16-21 allows flow proportional to the applied current
from 2 to 1 while severely restricting flow from 1 to 2. When energized, the valve
blocks flow from ports 2 to 1. In this mode, the cartridge will allow flow from 1 to 2
after overcoming the spring and actuator forces.
FEATURES
Industry-common cavity.
Efficient wet-armature construction.
Continuous-duty rated coils.
Optional waterproof E-Coils rated up to IP69K.
• 1000-hour salt-spray rated solenoid tubes.
• All HyPerformance products are tested to NFPA specification T2.6.1,
and are tested at a verification level of 90% and an assurance of 99%.
RATINGS
Operating Pressure: 350 bar (5075 psi); 10% Cycle Life: 420 bar (6090 psi)
Proof Pressure: 690 bar (10000 psi)
Burst Pressure: 1380 bar (20000 psi)
Flow Rating: 76 lpm (20 gpm) with 5.5 bar (80 psi) compensation; 95 lpm (25 gpm)
with 11.0 bar (160 psi) compensation
Max. Internal Leakage: 7 drops per minute at 350 bar (5075 psi) at port 2
Cycle Life: One million cycles
Operating Fluid Temperature: -54 to 107°C (-65 to 224°F) with urethane seals
Fluids: Mineral-based or synthetics with lubricating properties at viscosities
of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Filtration: See page 9.010.1
Installation: No Restrictions. See page 9.020.1
Cavity: HVC16-2; See page 9.116.1
Cavity Tool: HCT16-2XX; See page 8.600.1
Seal Kit: SK16-2U-0 (urethane); See page 8.650.1
Coil Nut: Part No. 7004400
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROL
HSP16-21 HyPerformance
TM
Poppet, 2-Way, N. O.
ISO SYMBOL
2.023.3
PERFORMANCE
HYDRAFORCE
.com
®
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
FLOW lpm/gpm
113.6/30
94.6/25
75.7/20
56.8/15
37.9/10
18.9/5
0
FLOW vs. CURRENT
5.5 bar (80 psi) Compensated
11.0 bar (150 psi) Compensated
CURRENT (ampere)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
PRESSURE RESPONSE
(Cartridge only)
2-1, De-energized; 1-2, Energized
37.9
10
75.7
20
113.6
30
151.4
40
189.3
50
227.1
60
FLOW lpm/gpm
13.8/200
27.6/400
41.1/600
55.2/800
68.9/1000
82.7/1200
PRESSURE bar/psi
265.0
70
Blue rectangles are links to other catalog pages.
Seals
Urethane U
Urethane seals recommended
for operating pressures above
241 bar (3500 psi).
HSP16-21
2.023.4
DIMENSIONS
MATERIALS
Cartridge: Weight: 0.44 kg.
(0.97 lbs.); Steel with hardened
work surfaces. Zinc-plated
exposed surfaces. Urethane
seals without back-up rings
standard.
Ported Body:
Weight: 3.97 kg.
(8.75 lbs.); HyPerformance™
Ductile iron (code ‘D’) standard.
Rated to 345 bar (5000 psi).
See page 8.016.1.
E-Coil: Weight: 0.41 kg. (0.9 lbs.);
Perfect wound, fully encapsulated
with rugged external metal shell.
Rated up to IP69K with integral
connectors. See page 3.400.1.
TO ORDER
Voltage
0 Less Coil**
12 12 VDC
24 24 VDC
**Includes Std. Coil Nut
Consult factory for
additional voltage
options.
HSP16-21 __ - __ __ __ - __ - __ __ __ __ __
Coil Termination
ER Deutsch DT04-2P
(IP69K Rated)
EY Metri-Pack
® 150
(IP69K Rated)
EL Dual Lead Wires
(IP69K Rated)
EJ Amp Jr. Timer
(IP67K Rated)
EG DIN 43650
(IP65K Rated)
Consult factory for additional
seal options.
Porting
Cartridge Only 0
SAE 16 16TD
1 in. BSP* 8BD
*BSP Body; U.K. Mfr. Only
Option
None
(Blank)
HYDRAFORCE
.com
®
1.62
41.1
1.84
DIA.
46.7
COIL MUST BE
INSTALLED WITH
LETTERING UP
3.39
ORIFICE DISC CANNOT
BE USED WITH THIS PRODUCT
due to HyPerformance
TM
Cavity.
82.6
1.56
ACROSS FLATS
39.8
1.85
TORQUE: 5 – 7 ft-lb.
TORQUE:
190– 210 ft-lb.
47.0
3.25
82.6
1.60
40.6
3.50
88.9
0.35
8.8
2.56
65.0
1.00
25.4
2.25
57.2
3.50
88.9
0.344 (8.7 mm)
Dia. Mounting
Holes (2)
6.8 – 9.5 Nm
258 – 285 Nm
®
HYDRAFORCE
For Coils with Zener Diode, add “/Z” to
option code. For example: “ER/Z”. Not
available on all models.
See coil option info. on page 3.400.1
Blue rectangles are links to other catalog pages.