DESCRIPTION
A high pressure proportional solenoid-operated, two-way, piloted, poppet-type,
normally open, screw-in hydraulic cartridge valve for low-leakage blocking and load-
holding applications.
OPERATION
When de-energized, the HSP10-21 allows flow proportional to the applied current
from from ports 2 to 1 while severely restricting flow from ports 1 to 2. When ener-
gized, the valve blocks flow from ports 1 to 2 after overcoming the spring and actuator
forces (see performance graph.)
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
• Industry-common cavity.
• Efficient wet-armature construction.
• Continuous-duty rated coils.
• Optional waterproof E-Coils rated up to IP69K.
• All HyPerformance products are tested to the rigorous standards
of the NFPA specification T2.6.1.
• All HyPerformance valves are tested at a verification level of 90%
and an assurance of 99%.
RATINGS
Operating Pressure: 350 bar (5075 psi); 10% cycle life: 420 bar (6090 psi)
Flow Rating: 53 lpm (14 gpm) with 11 bar (160 psi) compensation; 34 lpm (9 gpm)
with 5.5 bar (80 psi) compensation
Max. Internal Leakage: 5 drops per minute at 350 bar (5075 psi) at port 2
Cycle Life: One million cycles
Temperature: -54° to 107°C (-65° to 225°F) with Urethane seals
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Filtration: See page 9.010.1
Installation: No Restrictions. See page 9.020.1
Cavity: HVC10-2; See page 9.110.1
Cavity Tool: HCT10-2XX; See page 8.600.1
Seal Kit: SK10-2U-0 Urethane; See page 8.650.1
Coil Nut: Part No. 4553800; for E-coils manuf. prior to 1-1-04, see page 3.400.1
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROL
HSP10-21 HyPerformance™ Proportional, Poppet, 2-Way,
2.021.3
ISO SYMBOL
CURRENT (amps)
1.2 amps = 100% of Max. Control Current
FLOW (lpm/gpm)
Flow vs. Current, 242 bar (3000 psi)
Inlet with No Compensation
100 Hz Dither Frequency
0.4 0.6 0.8 1.0 1.20.20
227/60
189/50
151/40
114/30
76/20
38/10
PERFORMANCE
CURRENT (amps)
1.2 amps = 100% of Max. Control Current
FLOW (lpm/gpm)
Flow vs. Current
With Compensation
100 Hz Dither Frequency
0.4 0.6 0.8 1.0 1.20.20
60.6/16
53.0/14
45.4/12
37.9/10
30.3/8
22.7/6
7.6/2
15.0/4
80 psi
Compensated
160 psi
Compensated
HYDRAFORCE
.com
®
Pressure Drop vs. Flow
32 cSt/150 sus oil at 40°C
69/1000
55/800
41/600
28/400
14/200
15
4
30
8
45
12
0.25 A
0.50 A
0 A
61
16
FLOW lpm/gpm
PRESSURE DROP bar/psi
76
20
De-Energized 1–2