DESCRIPTION
A high pressure proportional solenoid-operated, two-way, piloted, poppet-type, nor-
mally closed, screw-in hydraulic cartridge valve for low-leakage blocking and load-
holding applications.
OPERATION
When de-energized, the HSP10-20 blocks flow from ports 2 to 1. In this mode, the
cartridge will allow flow from ports 1 to 2 after overcoming the spring forces (see
Performance graph). When energized, the valve will allow flow proportional to the
applied current from ports 2 to 1 while severely restricting flow from ports 1 to 2.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
Industry-common cavity.
Efficient wet-armature construction.
Continuous-duty rated coils.
Waterproof E-Coils rated up to IP69K.
Manual override option.
• All HyPerformance products are tested to the rigorous standards
of the NFPA specification T2.6.1.
• All HyPerformance valves are tested at a verification level of 90%
and an assurance of 99%.
RATINGS
Operating Pressure: 350 bar (5075 psi); 10% cycle life: 420 bar (6090 psi)
Flow Rating: 53 lpm (14 gpm) with 11 bar (160 psi) compensation; 34 lpm (9 gpm)
with 5.5 bar (80 psi) compensation
Max. Internal Leakage: 5 drops per minute at 350 bar (5075 psi) at port 2
Cycle Life: One million cycles
Temperature: -54° to 107°C (-65° to 225°F) with urethane seals
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Filtration: See page 9.010.1; Installation: No Restrictions. See page 9.020.1
Cavity: HVC10-2; See page 9.110.1; Cavity Tool: HCT10-2XX; See page 8.600.1
Seal Kit: HSK10-2U-0 Urethane; See page 8.650.1
Coil Nut: Part No. 4553800; for E-coils manuf. prior to 1-1-04, see page 3.400.1.
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROL
HSP10-20 HyPerformance™ Proportional, Poppet, 2-Way,
2.011.1
ISO SYMBOL
CURRENT (amps)
1.2 amps = 100% of Max. Control Current
FLOW (lpm/gpm)
Flow vs. Current, 242 bar (3000 psi)
Inlet with No Compensation
100 Hz Dither Frequency
0.4 0.6 0.8 1.0 1.20.20
227/60
189/50
151/40
114/30
76/20
38/10
PERFORMANCE
CURRENT (amps)
1.2 amps = 100% of Max. Control Current
FLOW (lpm/gpm)
Flow vs. Current
With Compensation
100 Hz Dither Frequency
0.4 0.6 0.8 1.0 1.20.20
60.6/16
53.0/14
45.4/12
37.9/10
30.3/8
22.7/6
7.6/2
15.0/4
160 psi
Compensated
80 psi
Compensated
Pressure Drop vs. Flow
32 cSt/150 sus oil at 40°C
69/1000
55/800
41/600
28/400
14/200
15
4
30
8
45
12
1.00 A
0.70 A
1.24 A
61
16
FLOW lpm/gpm
PRESSURE DROP bar/psi
76
20
De-Energized 1–2
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
HSP10-20
2.011.2
DIMENSIONS
COIL MUST BE
INSTALLED WITH
LETTERING UP
3.25
ORIFICE DISC CANNOT
BE USED WITH
THIS PRODUCT
due to HyPerformance
TM
Cavity.
82.5
1.00
ACROSS FLATS
25.4
0.75
ACROSS FLATS
‘T’-Type
Manual Override
19.0
1.31
TORQUE: 5 – 7 ft-lb.
6.8 – 9.5 Nm
TORQUE:
75 – 85 ft-lb.
102 – 115 Nm
33.3
0.75
19.1
1.50
38.1
2.54
64.5
2.00
50.8
0.281 (7.1 mm)
Dia. Mounting
Holes (2)
2.43
61.7
1.62/41.1
1.00/25.4
2.43/61.7
1.84/46.7 DIA.
0.20/5.1
1.63/41.3
MATERIALS
Cartridge: Weight: 0.18 kg.
(0.4 lbs.) without coil and nut.
Steel with hardened work
surfaces. Zinc-plated exposed
surfaces. PPDI Urethane seals
without back-ups standard.
Standard Ported Body: Weight:
1.18 kg. (2.62 lbs.) HyPerfor-
mance™ Ductile iron (code 'D')
standard. Rated to 345 bar
(5000 psi) See page 8.010.1.
E-Coil: Weight: 0.41 kg. (0.9 lbs.)
Perfect wound, fully encapsu-
lated with rugged external metal
shell. Rated up to IP69K with
integral connectors. Note: See
page 3.400.1 for all E-Coil
retrofit applications.
HSP10-20 __ - __ __ __ - __ - __ __ __ __ __
TO ORDER
Termination (VDC)
E-Coil
ER Deutsch DT04-2P
(IP69K Rated)
EY Metri-Pack
® 150.2A
(IP69K Rated)
EL Dual Leads
Porting
Cartridge Only 0
SAE 8 8TD
1/2 in. BSP* 4BD
*BSP Body; U.K. Mfr. Only
Seals
U PPDI Urethane
Consult factory for additional
seal options.
Option
None
(Blank)
Manual Override T
Voltage
0 Less Coil**
12 12 VDC
24 24 VDC
**Includes Std. Coil
Nut
Consult factory for
additional voltage
options.
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
Normally Closed
®
HYDRAFORCE
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.