DESCRIPTION
A solenoid-operated, 4-port, 3-position, direct-acting, spool-type, closed center,
screw-in hydraulic cartridge valve for use in high pressure, high flow applications.
OPERATION
When de-energized, the HSV10-47D blocks the inlet port while allowing flow from
ports 2 and 4 to port 1. When coil #1 is energized, flow is allowed from 3 to 4, and
from 2 to 1. When coil #2 is energized, flow is allowed from 3 to 2, and from 4 to 1.
Manual Override Option: The manual override feature is intended for emergency
use, not for continuous operation. For normal valve operation (neutral), the manual
override pin must be seated in the center detent groove (ID groove on knob is in-line
with top of coil nut). To shift the valve manually from neutral to activate coil S1 func-
tion, push the knob down slightly, rotate 90 degrees counterclockwise and pull. To
detent in this position, rotate the knob an additional 90 degrees counterclockwise
to lock in the upper detent groove. To shift manually from neutral to activate coil S2
function, push the knob down all the way to detent. In this position, rotate the knob
ninety degrees clockwise to lock in the lower detent groove.
FEATURES
• Manual override option.
• Unitized, molded coil design.
• Waterproof E-Coils rated up to IP69K.
• Corrosion-resistant plating.
• Continuous-duty rated solenoid with patented, high-strength solenoid tube.
• Hardened precision spool and cage for long life.
• All ports may be fully pressurized.
• All HyPerformance™ products are tested to the rigorous standards of the NFPA
specification T2.6.1.
• All HyPerformance™ valves are tested at a verification level of 90% and an as-
surance of 99%.
RATINGS
Operating Pressure: 350bar (5075psi); 10% cycle life: 420bar (6090psi)
Note: All HyPerformance™ products are tested for 900K cycles at 350bar and
100K cycles at 420bar.
Proof Pressure: 690bar (10000psi)
Burst Pressure: 1380bar (20000psi)
Flow Rating: 34lpm (9gpm)
Internal Leakage: Ports 3-1: 35 cu.in./min (575 ml/min) at 350bar (5075psi)
de-energized
Temperature: -54 to 107°C (-65 to 225°F) with urethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC10-4; See page 9.110.1
Cavity Tool: HCT10-4XX; See page 8.600.1
Seal Kit: SK10-4U-000; See page 8.650.1
HSV10-47D HyPerformance™ Spool, 4-Port,
ISO SYMBOL
1.532.3
PERFORMANCE (Cartridge Only)
PRESSURE DROP vs. FLOW
3 to 2 2 to1
3 to 4 4 to 1
32 cSt/150 sus oil at 40°C
17.2/250
13.7/200
10.3/150
6.9/100
3.4/50
15.1
4
30.3
8
37.9
10
FLOW lpm/gpm
PRESSURE DROP bar/psi
7.6
2
22.7
6
11.36/3
7.57/2
3.8/1
0
138
2000
69
1000
207
3000
276
4000
LOAD PRESSURE bar/psi
FLOW RATING lpm/gpm
FLOW RATING vs. PRESSURE DIFFERENTIAL
Inlet at Port 1
Inlet at Port 3
Inlet at Port 1
345
5000
414
6000
15.14/4
18.93/5
22.7/6
26.50/7
30.28/8
34.07/9
37.85/10
Inlet at Port 3
SOLENOID VALVES
HYDRAFORCE
.com
®
U.S. Patent
8,253,063
Blue rectangles are links to other catalog pages.