SV10-43 Spool, 4-Way, 2-Position
DESCRIPTION
A solenoid-operated, 4-way, 2-position, direct-acting, spool-type, screw-in hydraulic
cartridge valve.
OPERATION
When de-energized, the SV10-43 allows fl ow from ➃ to ➀, while blocking ➂ and ➁.
When energized, the spool shifts to allow fl ow from
➂ to ➃ and from ➁ to ➀.
Note that while
➀ may be fully pressurized, it is not intended for use as the inlet.
Operation of Manual Override Option: To override, push button in and twist counter-
clockwise 180°. The internal spring will push the button out. In this position, the valve
may be only partially shifted. To assure full override shift, pull the button out to its full-
est extension and hold it in this position.
To return to normal valve function, push button in, twist clockwise 180°, and release.
Override will be detented in this position.
FEATURES
• Continuous-duty rated solenoid.
• Hardened precision spool and cage for long life.
• Optional coil voltages and terminations.
• Effi cient wet-armature construction.
• All ports may be fully pressurized.
• Cartridges are voltage interchangeable.
• Manual override option.
• Optional waterproof E-Coils rated up to IP69K.
• Unitized, molded coil design.
• Industry common cavity.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Proof Pressure: 350 bar (5075 psi)
Flow: See Performance Chart
Internal Leakage: 82 cc/minute (5 cu. in./minute) max. at 207 bar (3000 psi
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectifi ed).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-4; See page 9.110.1
Cavity Tool: CT10-4XX; See page 8.600.1
Seal Kit: SK10-4X-MMM; See page 8.650.1
Coil Nut: Part No. 7004400;
For E-coils manufactured prior to 1-1-04, see page 3.400.1 for coil nut info.
USASI/ISO:
1.442.1
6.9/100
5.5/80
4.1/60
2.8/40
1.4/20
7.5
2
15.1
4
22.5
6
FLOW lpm/gpm
PRESSURE DROP bar/psi
➂ to ➃ ——
➁ to ➀ - - - -
➃ to ➀ – – –
32 cSt/150 sus oil at 40°C
SOLENOID VALVES
HYDRAFORCE
.com
®
SYMBOLS
PERFORMANCE
(Cartridge Only)