SV10-40 Spool, 4-Way, 2-Position
DESCRIPTION
A solenoid-operated, four-way, two-position, direct-acting, spool-type, screw-in
hydraulic cartridge valve.
OPERATION
When de-energized, the SV10-40 allows flow from to , as well as from to .
When energized, the cartridges spool shifts to open
to , and to .
FEATURES
Continuous-duty rated solenoid.
Hardened precision spool and cage for long life.
Optional coil voltages and terminations.
Efficient wet-armature construction.
All ports may be fully pressurized.
Cartridges are voltage interchangeable.
Manual override option.
Optional waterproof E-Coils rated up to IP69K.
Unitized, molded coil design.
Industry common cavity.
RATINGS
Operating Pressure: 207bar (3000psi)
Proof Pressure: 276bar (4000psi)
Burst Pressure: 621bar (9000psi)
Flow: 23lpm (6gpm) max.
Internal Leakage: 82 cc/minute (5 cu. in./minute) max. at 207bar (3000psi)
Temperature: -40 to 100° C (-40 to 212°F) with standard Buna N seals;
-26 to 204°C (-15 to 400°F) with standard fluorocarbon seals;
-54 to 107°C (-65 to 225°F) with standard polyurethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 A at 12Vdc;
0.18 A at 115Vac (full wave rectified).
E-Coil: 1.7 A at 12Vdc; 0.85 A at 24Vdc
Minimum Pull-in Voltage: 85% of nominal at 207bar (3000psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-4; See page 9.110.1
Cavity Tool: CT10-4XX; See page 8.600.1
Seal Kit: SK10-4X-MMM; See page 8.650.1
Coil Nut: Part No. 7004400;
For E-coils manufactured prior to 1-1-04, see page 3.400.1 for coil nut info.
SYMBOLS
PERFORMANCE (Cartridge Only)
1.407.1
6.9/100
5.2/75
3.4/50
1.7/25
7. 5
2
15.1
4
22.7
6
FLOW lpm/gpm
PRESSURE DROP bar/psi
3 to 2 ——
4 to 1 - - - -
32 cSt/150 sus oil at 40°C
SOLENOID VALVES
HYDRAFORCE
.com
®
ISO: with Sensor:
4.8/70
4.1/60
3.4/50
2.8/40
2.0/30
1.4/20
0.7/10
FLOW lpm/gpm
PRESSURE DROP bar/psid
SV10-40 with Sensor
Port 4 to 1 and 3 to 2 de-energized - - - - -
Port 3 to 4 energized — -
Port 1 to 2 energized —
32 cSt/150 sus oil at 40°C (104°F)
3.8
1
7. 6
2
11.4
3
15.9
4
18.9
5
22.7
6
0
SENSOR OUTPUT
Typical Sensor Output & Flow vs. Valve Shift
VALVE SHIFT %
Hatched Area: Overlapping Stroke, Leakage Flow
FLOW
0.04 lpm
0.2 gpm
22.7 lpm
6 gpm
0
41
53
50
100
Vcc
VOUT2
3-4 FLOW
Blue rectangles are links to other catalog pages.
SV10-40
DIMENSIONS
1.407.2
1.62
41.1
1.84
DIA.
46.7
0.291
7.40
E-Coil
View
Standard
Coil View
2.38
60.3
2.69
68.4
3.48
88.41
3.37
85.74
J Override
Option
Y Override
Option
®
HYDRAFORCE
HYDRAFORCE
.com
®
TO ORDER
Cartridge: Weight: 0.20kg
(0.45lb); Steel with hardened
work surfaces. Zinc-plated
exposed surfaces. BunaN
O-rings and polyester elasto-
mer back-up standard.
Standard Ported Body: Weight:
0.36kg (0.80lb); Anodized
high-strength 6061 T6 alumi-
num alloy, rated to 207bar
(3000psi). Ductile iron bodies
available; dimensions may
differ. See page 8.010.1.
Standard Coil: Weight: 0.27kg
(0.60lb); Unitized thermoplas-
tic encapsulated, Class H high
temperature magnet wire.
See page 3.200.1.
E-Coil: Weight: 0.41kg (0.9lb);
Fully encapsulated with
rugged external metal shell.
Rated up to IP69K with inte-
gral connectors.
Note: See page 3.400.1 for
all E-Coil retrofit applica-
tions.
MATERIALS
SV10-
(P)
40 - __ - __ __ __ - __ - __ __ __ - __ __ - __ __
Option
None (Blank)
Manual Override M
Manual Override Y
Manual Override J
For Manual Override options
see page 1.001.1
Porting
Cartridge Only 0
SAE 6 6T
SAE 8 8T
1/4 in. BSP* 2B
3/8 in. BSP* 3B
1/2 in. BSP* 4B
*BSP Body; U.K. Mfr. Only
Voltage
Std. Coil
0 Less Coil**
10 10 VDC
12 12 VDC
24 24 VDC
36 36 VDC
48 48 VDC
24 24 VAC
115 115 VAC
230 230 VAC
**Includes Coil Nut
DS, DW or DL
terminations only
E-Coils: 10,12,20
or 24 VDC only.
For Coils with Zener Diode, add /Z to option code.
For example: ER/Z. Not available on all models.
See coil option info. on pages 3.200.1 & 3.400.1
Coil Termination E-Coil D-Coil
Deutsch DT04-2P ER
(IP69K) DR (IP65)
Metri-Pack
®
150 EY (IP69K) DY (IP65)
Dual Lead Wires EL (IP69K) DL (IP65)
Amp Jr. Timer EJ (IP67)
DIN 43650 EG
(IP65) DG (IP65)
Dual Spades DS (IP65)
Seals
N Buna N (Std.)
V Fluorocarbon
Sensor Option: See page 3.010.1
Sensor/Connector
(Blank) None
N Neutral Sense/DT04-4P
M Neutral Sense/M12-4P
Mating Connectors:
DT06-4S: Part No. 4001953
M12-4S: available at www.turck.com
or www.binder-usa.com
Position
Indicator
None (Blank)
Switch P
Sensor Type
(Blank) None
3 Dual Output,
N.C./N.O.
with sensor, valve is rated
3000 psi (207 bar)
Blue rectangles are links to other catalog pages.