DESCRIPTION
A solenoid-operated, normally-closed, on/off, poppet-type, screw-in hydraulic
cartridge valve incorporating an integral load-sense pressure port with isolation check.
OPERATION
When de-energized, the SVCL10-32 blocks flow at ports 3 and 1. When energized,
flow is allowed from 3 to 1 and 2 with a check-isolated load sense signal supplied at
2. Reverse flow is not allowed from 1 to 3.
NOTE: When using this valve in bridge circuits, seals should not be used on the pilot
pistons of the pilot-operated check valves. This is to avoid trapping oil which would
keep the pilot-operated check valve open.
FEATURES
Continuous-duty rated solenoid.
Hardened precision spool and cage for long life.
Optional coil voltages and terminations.
Efficient wet-armature construction.
All ports may be fully pressurized.
Cartridges are voltage interchangeable.
Optional waterproof E-Coils rated up to IP69K.
Unitized, molded coil design.
Reduce manifold space claim.
RATINGS
Operating Pressure: 250 bar (3625 psi); Holding Pressure at 1: 250 bar (5000 psi)
Flow: 15 gpm (57 lpm); see performance charts
Internal Leakage: Ports 1 and 3: 5 drops/minute max. at 250 bar (3625 psi)
Port 2: 10 drops/minute max. at 250 bar (3625 psi)
Operating Temperature: -40° to 100°C (-40° to 212° F) with standard Buna N seals;
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals;
-54°C to 104°C (-65°F to 225°F) with Polyurethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard D-Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-3, Variation “B”; See page 9.110.1
Cavity Tool: CT10-3XX; See page 8.600.1
Seal Kit: SK10-3X-MM; See page 8.650.1
Coil Nut: Part No. 7004400
SVCL10-32 Poppet, 3-Port, Normally Closed
SYMBOL
1.315.1
PERFORMANCE (Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
ISO:
Expanded:
3 to 1
32 cSt/150 sus oil at 40°C
17.2/250
13.7/200
10.3/150
6.9/100
3.4/50
22.7
6
45.4
12
56.8
15
FLOW lpm/gpm
PRESSURE DROP bar/psi
11.4
3
34.1
9
3 to 2 1.2A
32 cSt/150 sus oil at 40°C
1.03/15
0.83/12
0.62/9
0.41/6
0.21/3
0.76
0.2
1.52
0.4
1.90
0.5
FLOW lpm/gpm
PRESSURE DROP bar/psi
0.38
0.1
1.14
0.3
U.S. Patent
7,921,880
Blue rectangles are links to other catalog pages.
DIMENSIONS
SVCL10-32
1.315.2
TO ORDER
Cartridge: Weight: 0.18 kg.
(0.40 lbs.); Steel with hardened
work surfaces. Zinc-plated
exposed surfaces. Buna N
O-rings and polyester elastomer
back-up standard.
Standard D-Coil: Weight: 0.27 kg.
(0.60 lbs.); Unitized thermoplas-
tic encapsulated, Class H high
temperature magnetwire. See
page 3.200.1.
E-Coil: Weight: 0.41 kg. (0.9 lbs.);
Fully encapsulated with rugged
external metal shell. Rated up to
IP69K with integral connectors.
Note: See page 3.400.1 for all
E-Coil retrofit applications.
MATERIALS
®
HYDRAFORCE
HYDRAFORCE
.com
®
1.62
41.1
1.84
DIA.
46.7
E-Coil
View
TORQUE
5–7 ft-lbs
(6.8–9.5 Nm)
TORQUE
33–37 ft-lbs
(44.8–50.2 Nm)
1.00
25.4
2.93
74.4
2.32
59.0
0.87
22.1
1.48
37.6
D-Coil
View
U.S. Patent 7,921,880
SVCL10-32__ - __ __ __ - __ - __ __ __ __ __
Porting
Cartridge Only 0
Seals
Buna N (Std.) N
Fluorocarbon V
Polyurethane P
Voltage
0 Less Coil**
12 12 VDC
20 20 VDC
24 24 VDC
**Includes D-Coil Nut
For Coils with Zener Diode, add “/Z” to option code.
For example: “ER/Z”. Not available on all models.
See coil option info. on pages 3.200.1 & 3.400.1
Coil Termination E-Coil D-Coil
Deutsch DT04-2P ER (IP69K) DR (IP65)
Metri-Pack
®
150 EY (IP69K) DY (IP65)
Dual Lead Wires EL (IP69K) DL (IP65)
Amp Jr. Timer EJ (IP67)
DIN 43650 EG (IP65) DG (IP65)
Dual Spades DS (IP65)
Option
None (Blank)
Manual Override M