SVCV08-20 Poppet, 2-Way, Normally Closed . . .
DESCRIPTION
A solenoid-operated, two-way, pilot-operated, poppet-type, normally closed, screw-in
hydraulic cartridge valve with outlet fl ow check, designed for low leakage in load
holding applications.
OPERATION
When de-energized, the SVCV08-20 blocks fl ow from to and from to .
When energized, the cartridge’s poppet lifts to open the
to ow path, while
continuing to block fl ow from
to .
The SVCV08-20 is designed to fi t into the VC08-3 cavity with the normal inlet at cav-
ity port 3 (valve port
), the outlet at cavity port (valve port ), and cavity port
blocked. The pressure drop will be substantially higher if cavity port
is selected as
an alternate outlet port.
Operation of Manual Override Option: To override, push button in, twist counter-
clockwise 180°, and release. In this position, the valve will remain open.
To return to normal operation, push button in, twist clockwise 180°, and release.
Override will be detented in this position.
FEATURES
Continuous-duty rated coil.
Hardened seat for long life and low leakage.
Optional coil voltages and terminations.
Manual override option.
Cartridges are voltage interchangeable.
Optional waterproof E-Coils rated up to IP69K.
Industry common cavity.
Compact size.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Rated Flow: 22.7 lpm (6 gpm)
Reverse Flow Check Valve Spring: 0.69 bar (10 psi)
Maximum Internal Leakage:
to : 5 drops/minute at 207 bar (3000 psi);
to : 10 drops/minute at 207 bar (3000 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied at
80% of nominal fl ow rating:
Energized: 40 msec.; De-energized: 46 msec.
Initial Coil Current Draw at 20°C: Standard Coil: 1.2 amps at 12 VDC;
0.13 amps at 115 VAC (full wave rectifi ed);
E-Coil: 1.4 amps at 12 VDC; 0.7 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-3; See page 9.108.1
Cavity Tool: CT08-3XX; See page 8.600.1
Seal Kit: SK08-3X-M; See page 8.650.1
Coil Nut: Part No. 7004400
SYMBOLS
ISO:
PERFORMANCE (Cartridge Only)
1.115.1
8.6/125
6.9/100
5.2/75
3.4/50
1.7/25
11.4
3
7.6
2
3.8
1
15.1
4
18.9
5
FLOW lpm/gpm
PRESSURE DROP bar/psi
Valve: to
3-Way Cavity: to
32 cSt/150 sus oil at 40°C
22.7
6
10.3/150
SOLENOID VALVES
HYDRAFORCE
.com
®
Expanded:
Blue rectangles are links to other catalog pages.
SVCV08-20
DIMENSIONS
1.115.2
1.88
TORQUE
4–5 ft-lb
(5.4–6.8 Nm)
TORQUE
19–21 ft-lb
(25.8–28.5 Nm)
47.8
1.63
41.3
E-Coil
View
1.40
35.6
1.41
COIL MUST BE INSTALLED
WITH LETTERING UP
DIA.
35.8
Standard
Coil View
Plugged
0.43
10.9
with Outlet Flow Check
SVCV08-20__ - __ __ __ - __ - __ __ __ __ __
TO ORDER
Seals
Buna N (Std.) N
Fluorocarbon V
Termination (VDC)
Std. Coil
DS Dual Spades
DG DIN 43650
DL Leadwires (2)
DL/W Leads w/Weatherpak
®
Connectors
DR Deutsch DT04-2P
Termination (VAC)
Std. Coil
AG DIN 43650
AP 1/2 in. Conduit
Termination (VDC)
E-Coil
ER Deutsch DT04-2P
(IP69K Rated)
EY Metri-Pack
® 150
(IP69K Rated)
Coils with internal diode are
available. Consult factory.
E-Coil
10 10 VDC
12 12 VDC
20 20 VDC
24 24 VDC
Voltage
Std. Coil
0 Less Coil**
10 10 VDC
12 12 VDC
24 24 VDC
36 36 VDC
48 48 VDC
24 24 VAC
115 115 VAC
230 230 VAC
**Includes Std. Coil Nut
DS, DW or DL
terminations only.
MATERIALS
Cartridge: Weight: 0.11 kg.
(0.25 lbs.); Steel with hardened
work surfaces. Zinc-plated
exposed surfaces; Buna N
O-rings and back-ups standard.
Standard Ported Body: Weight:
0.27 kg. (0.60 lbs.); Anodized
high-strength 6061 T6 aluminum
alloy, rated to 207 bar (3000 psi);
Ductile iron bodies available;
dimensions may differ.
See page 8.008.1.
Standard Coil: Weight: 0.11 kg.
(0.25 lbs.); Unitized thermoplastic
encapsulated, Class H high
temperature magnetwire.
See page 3.200.1.
E-Coil: Weight: 0.14 kg. (0.3 lbs.);
Perfect wound, fully encapsulated
with rugged external metal shell;
Rated up to IP69K with integral
connectors. See page 3.400.1
Porting
Cartridge Only 0
SAE 6 6T
SAE 8 8T
1/4 in. BSP* 2B
*BSP Body; U.K. Mfr. Only
®
HYDRAFORCE
HYDRAFORCE
.com
®
Option
None
(Blank)
Manual Override M
Blue rectangles are links to other catalog pages.