SV20-28 Poppet, 2-Way, N.C., Bi-Directional Blocking
PERFORMANCE (Cartridge Only)
1.096.1
SYMBOL
SOLENOID VALVES
HYDRAFORCE
.com
®
DESCRIPTION
A solenoid-operated, two-way, normally closed, internally piloted, poppet-type,
bi-directional blocking, screw-in hydraulic cartridge valve, designed for low leakage
in load-holding applications.
OPERATION
When de-energized, the SV20-28 blocks fl ow in both directions. When energized,
the valve’s poppet opens on its seat, allowing fl ow from
➁ to ➀ or ➀ to ➁.
FEATURES
• Continuous-duty rated coil.
• Optional coil voltages and terminations.
• Effi cient wet-armature construction.
• Cartridges are voltage interchangeable.
• Waterproof E-Coils rated up to IP69K.
• Hardened seat for long life and low leakage.
• Unitized, molded coil design.
• Cost-effective cavity.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Flow: Up to 303 lpm (80 gpm)
Internal Leakage: 5 drops/minute max. at 207 bar (3000 psi)
Operating Temperature: -40° to 100°C (-40° to 212° F) with standard Buna N seals
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard D-Coil: 1.2 amps at 12 VDC;
E-Coil: 1.4 amps at 12 VDC; 0.7 amps at 24 VDC
Minimum Pull-in Voltage: See Chart on this page.
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC20-2; See page 9.120.1
Cavity Tool: CT20-2XX; See page 8.600.1
Seal Kit: SK20-2x-M; See page 8.650.1
E-Coil Nut: Part No. 7085180
1
2
5.5/80
4.1/60
2.8/40
1.4/20
38
10
227
60
189
50
FLOW lpm/gpm
DIFFERENTIAL PRESSURE bar/psi
32 cSt/150 sus oil at 40°C
265
70
6.9/100
8.3/120
9.7/140
76
20
151
40
114
30
303
80
1 to 2
2 to 1
110
120
60 7050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (°C)
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage at the Coil Required for Pull-In
32 cSt/150 sus oil at 40°C
Operating Range
Blue rectangles are links to other catalog pages.