SV12-21 Poppet, 2-Way, Normally Open
DESCRIPTION
A solenoid-operated, 2-way, normally open, poppet-type, screw-in hydraulic cartridge
valve, designed to function as a load holding or blocking valve in applications
requiring low internal leakage.
OPERATION
When energized, the SV12-21 acts as a check valve, allowing flow to pass from 1 to
2, while blocking flow in the reverse direction.
When de-energized, the poppet lifts to open the 2 to 1 flow path after overcoming the
solenoid force (requires 3.4 to 10.3 bar / 50 to 150 psi). In this mode, flow from
1 to 2 is severely restricted. If this path is required, see model SV12-23,
page 1.054.1.
Operation of Manual Override Option: To override, push and hold override button.
FEATURES
• Continuous-duty rated solenoid.
• Hardened seat for long life and low leakage.
• Optional coil voltages and terminations.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Unitized, molded coil design.
• Manual override option.
• Optional waterproof E-Coils rated up to IP69K.
• Cost effective cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Flow: Up to 114 lpm (30 gpm); see performance chart
Internal Leakage: 0.15 cc/minute (3 drops/minute) max. at 240 bar (3500 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied at
80% of nominal flow rating: Energized: 110 msec.; De-energized: 40 msec.
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 240 bar (3500 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC12-2; See page 9.112.1
Cavity Tool: CT12-2XX; See page 8.600.1
Seal Kit: SK12-2X-T; See page 8.650.1
Coil Nut: Part No. 7004420;
For E-coils manufactured prior to 1-1-04, see page 3.400.1 for coil nut info.
ISO:
SYMBOLS
1.035.1
with Sensor:
10.3/150
8.3/120
6.2/90
4.1/60
2.1/30
37.9
10
75.8
20
113.6
30
FLOW lpm/gpm
PRESSURE DROP bar/psi
2 to 1 de-energized ——
1 to 2 energized - - - -
32 cSt/150 sus oil at 40°C
PERFORMANCE (Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
37.9
10
75.8
20
30
FLOW lpm/gpm
SV12-21 with Sensor
2 to 1 de-energized ——
1 to 2 energized - - - -
32 cSt/150 sus oil at 40°C
27.6/400
20.7/300
13.8/200
6.9/100
VALVE SHIFT %
FLOW
Vcc
SENSOR OUTPUT
Typical Sensor Output vs. Valve Shift
0
0.4 lpm
0.1 gpm
113.6 lpm
30 gpm
68 7350 100
VOUT
Hatched Area: Overlapping Stroke, Leakage Flow
Blue rectangles are links to other catalog pages.