SV10-20 Poppet, 2-Way, Normally Closed
DESCRIPTION
A solenoid-operated, 2-way, normally closed, poppet-type, screw-in hydraulic
cartridge valve, designed to function as a load holding or blocking valve in
applications requiring low internal leakage.
OPERATION
When de-energized, the SV10-20 acts as a check valve, allowing flow to pass from 1
to 2, while blocking flow in the reverse direction. With the sensor option, the neutral
sensor will signal ON or HIGH.
When energized, the poppet lifts to open the 2 to 1 flow path. In this mode,
flow from 1 to 2 is severely restricted. (If this path is required, see model SV10-22,
page 1.044.1.) With the sensor option, the neutral sensor will signal LOW or OFF.
Operation of Manual Override Option: To override, push button in, twist counter-
clockwise 180° and release. In this position, the valve will remain open.
To return to normal operation, push button in, twist clockwise 180° and release.
Override will be detented in this position.
FEATURES
Continuous-duty rated solenoid. Manual override option.
Hardened seat for long life and low leakage. Unitized, molded coil design.
Optional coil voltages and terminations. Industry common cavity.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Optional waterproof E-Coils rated up to IP69K.
RATINGS
Operating Pressure: 241 bar (3500 psi)
Proof Pressure: 345 bar (5000 psi)
Flow: Up to 56.8 lpm (15 gpm); see performance chart
Internal Leakage: 0.15 cc/minute (3 drops/minute) max. at 207 bar (3000 psi)
Temperature: -40 to 100°C (-40° to 212°F) with standard Buna N seals
-26 to 204°C (-15°F to 400°F) with Fluorocarbon seals
Sensor Option: -40°C to 110°C (-40°F to 230°F)
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied at
80% of nominal flow rating: Energized: 40 msec.; De-energized: 32 msec.
Response Time with Sensor: 53 ms pull-in, 110 ms drop-out
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-2; See page 9.110.1; Cavity Tool: CT10-2XX; See page 8.600.1
Seal Kit: SK10-2X-T; See page 8.650.1
Coil Nut: Part No. 7004400
ISO: with Sensor:
1.016.1
SYMBOLS
PERFORMANCE
(Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
8.6/125
6.9/100
5.2/75
3.4/50
1.7/25
11.4
3
22.7
6
34.1
9
45.4
12
FLOW lpm/gpm
PRESSURE DROP bar/psi
SV10-20 without Sensor
2 to 1 energized —
1 to 2 de-energized - - - -
32 cSt/150 sus oil at 40°C
56.8
15
13.8/200
16.5/240
19.3/280
11.0/160
8.3/120
5.5/80
2.8/40
11.3
3
22.7
6
34.1
9
45.4
12
FLOW lpm/gpm
PRESSURE DROP bar/psi
SV10-20 with Sensor
Port 2 to 1 Energized ——
Port 1 to 2 De-energized - - - -
32 cSt/150 sus oil at 40°C
56.8
15
VALVE SHIFT %
FLOW
Vcc
SENSOR OUTPUT
Typical Sensor Output vs. Valve Shift
0
0.3 lpm
0.08 gpm
56.8 lpm
15 gpm
15 20 50 100
VOUT
Hatched Area: Overlapping Stroke, Leakage Flow
Blue rectangles are links to other catalog pages.
SV10-20
DIMENSIONS
1.016.2
TO ORDER
SV10-
(P)
20
(A)
__ - __ __ __ - __ - __ __ __ __ __ - __ __
Option
None
(Blank)
Screen S
Manual Override M
Manual Override Y
Manual Override J
For Manual Override options
see page 1.001.1
1.62
41.1
1.84
DIA.
46.7
0.45
11.4
E-Coil
View
Standard
Coil View
2.38
60.3
Cartridge: Weight: 0.16 kg.
(0.35 lbs.); Weight with Sen-
sor option: 0.45 kg. (1.0 lbs.);
Steel with hardened work
surfaces. Zinc-plated exposed
surfaces. Buna N O-rings and
polyester elastomer back-up
standard.
Standard Ported Body:
Weight: 0.16 kg. (0.35 lbs.);
Anodized high-strength 6061
T6 aluminum alloy, rated to
207 bar (3000 psi). Ductile
iron bodies available;
dimensions may differ.
See page 8.010.1.
D-Coil: Weight: 0.27 kg.
(0.60 lbs.); Unitized thermo-
plastic encapsulated, Class H
high temperature magnetwire.
See page 3.200.1.
E-Coil: Weight: 0.41 kg.
(0.9 lbs.); Fully encapsulated
with rugged external metal
shell. Rated up to IP69K with
integral connectors.
See page 3.400.1.
Porting
Cartridge Only 0
SAE 6 6T
SAE 8 8T
1/4 in. BSP* 2B
3/8 in. BSP* 3B
1/2 in. BSP* 4B
*BSP Body; U.K. Mfr. Only
With sensor option, use
model code SV10-P20A . . .
See page 3.010.1
Without sensor option, use
model code SV10-20 . . .
Voltage
Std. Coil
0 Less Coil**
10 10 VDC
12 12 VDC
24 24 VDC
36 36 VDC
48 48 VDC
24 24 VAC
115 115 VAC
230 230 VAC
**Includes D-Coil Nut
DS, DW or DL
terminations only
E-Coils: 10,12,20
or 24 VDC only.
MATERIALS
®
HYDRAFORCE
HYDRAFORCE
.com
®
For Coils with Zener Diode, add “/Z” to option code.
For example: “ER/Z”. Not available on all models.
See coil option info. on pages 3.200.1 & 3.400.1
Coil Termination E-Coil D-Coil
Deutsch DT04-2P ER (IP69K) DR (IP65)
Metri-Pack
®
150 EY (IP69K) DY (IP65)
Dual Lead Wires EL (IP69K) DL (IP65)
Amp Jr. Timer EJ (IP67)
DIN 43650 EG (IP65) DG (IP65)
Dual Spades DS (IP65)
Sensor/Connector
N Neutral Sense/DT04-4P
M Neutral Sense/M12-4P
Mating Connectors:
DT06-4S: Part No. 4001953
M12-4S: available at www.turck.com
or www.binder-usa.com
Sensor Type
3 Dual Output,
N.C./N.O.
Seals
N Buna N (Std.)
V Fluorocarbon
Sensor Option: See page 3.010.1
Dimensions will differ significantly with Sensor Option; see page 3.010.1.
Blue rectangles are links to other catalog pages.