SV10-20 Poppet, 2-Way, Normally Closed
DESCRIPTION
A solenoid-operated, 2-way, normally closed, poppet-type, screw-in hydraulic
cartridge valve, designed to function as a load holding or blocking valve in
applications requiring low internal leakage.
OPERATION
When de-energized, the SV10-20 acts as a check valve, allowing flow to pass from 1
to 2, while blocking flow in the reverse direction. With the sensor option, the neutral
sensor will signal ON or HIGH.
When energized, the poppet lifts to open the 2 to 1 flow path. In this mode,
flow from 1 to 2 is severely restricted. (If this path is required, see model SV10-22,
page 1.044.1.) With the sensor option, the neutral sensor will signal LOW or OFF.
Operation of Manual Override Option: To override, push button in, twist counter-
clockwise 180° and release. In this position, the valve will remain open.
To return to normal operation, push button in, twist clockwise 180° and release.
Override will be detented in this position.
FEATURES
• Continuous-duty rated solenoid. • Manual override option.
• Hardened seat for long life and low leakage. • Unitized, molded coil design.
• Optional coil voltages and terminations. • Industry common cavity.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Optional waterproof E-Coils rated up to IP69K.
RATINGS
Operating Pressure: 241 bar (3500 psi)
Proof Pressure: 345 bar (5000 psi)
Flow: Up to 56.8 lpm (15 gpm); see performance chart
Internal Leakage: 0.15 cc/minute (3 drops/minute) max. at 207 bar (3000 psi)
Temperature: -40 to 100°C (-40° to 212°F) with standard Buna N seals
-26 to 204°C (-15°F to 400°F) with Fluorocarbon seals
Sensor Option: -40°C to 110°C (-40°F to 230°F)
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied at
80% of nominal flow rating: Energized: 40 msec.; De-energized: 32 msec.
Response Time with Sensor: 53 ms pull-in, 110 ms drop-out
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-2; See page 9.110.1; Cavity Tool: CT10-2XX; See page 8.600.1
Seal Kit: SK10-2X-T; See page 8.650.1
Coil Nut: Part No. 7004400
ISO: with Sensor:
1.016.1
SYMBOLS
PERFORMANCE
(Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
8.6/125
6.9/100
5.2/75
3.4/50
1.7/25
11.4
3
22.7
6
34.1
9
45.4
12
FLOW lpm/gpm
PRESSURE DROP bar/psi
SV10-20 without Sensor
2 to 1 energized ——
1 to 2 de-energized - - - -
32 cSt/150 sus oil at 40°C
56.8
15
13.8/200
16.5/240
19.3/280
11.0/160
8.3/120
5.5/80
2.8/40
11.3
3
22.7
6
34.1
9
45.4
12
FLOW lpm/gpm
PRESSURE DROP bar/psi
SV10-20 with Sensor
Port 2 to 1 Energized ——
Port 1 to 2 De-energized - - - -
32 cSt/150 sus oil at 40°C
56.8
15
VALVE SHIFT %
FLOW
Vcc
SENSOR OUTPUT
Typical Sensor Output vs. Valve Shift
0
0.3 lpm
0.08 gpm
56.8 lpm
15 gpm
15 20 50 100
VOUT
Hatched Area: Overlapping Stroke, Leakage Flow
Blue rectangles are links to other catalog pages.