Manual Override Options
1. 0 01. 1
Manual Override "M" Option for Two-Position Pull-Type Solenoid Valves
Manual Override "M" and "B" Option for Three-Position Push/Pull-Type Solenoid Valves
Exaggerated illustration of operation of Manual Override "M" option
*Note: All manual override features are intended for emergency use, not for continuous-duty operation.
UPPER
SPRINGS
NEUTRAL>
OVERRIDE
OVERRIDE>
NEUTRAL
To Override:
1) Push Down
To Return
to Normal
Operation:
1) Push
Button
Down
2) Twist Button
Counterclockwise 180°
2) Twist Button
Clockwise 180°
3) Release
Button
3) Release
Button
8 SIZE
8 SIZE
Dual-Coil Valves
10 SIZE
10 SIZE
Dual-Coil Valves
Manual Override "K" Option for Three-Position Push/Pull-Type Solenoid Valves, Detented
Option
"B"
Option
"M"
Option
"B"
Option
"M"
Operation of Manual Override: To override, from neutral push button in, twist clockwise 90°, to activate coil #2 (S2) function.
From neutral pull and twist 90° counterclockwise to activate coil #1 (S1) function.
Operation of Manual Override: To override, push the knurled button to activate the coil #2 (S2) function, or pull the knob
to activate the coil #1 (S1) function.
SOLENOID VALVES
HYDRAFORCE
.com
®
Manual Override Options
1. 0 01. 2
Manual Override "P" and "K" Options for
Two-Position Push-Type Solenoid Valves
Manual Override "J" and "Y" Options for Pull-Type Solenoid Valves
Siz
es: -08, -38, -10, -12, -16
MANUAL
OVERRIDE
OPTION “P”
MANUAL OVERRIDE OPTION “J”
WITH RED KNOB (#6113032)
ORDERED SEPARATELY
MANUAL OVERRIDE OPTION “Y”
MANUAL OVERRIDE OPTION “J”
MANUAL
OVERRIDE
KNOB (#6113040)
OPTION “K”
Manual Override "M" and "G" Options for
PV and ZL Proportional Valves
Manual
Override ‘G’
with Guard
Manual
Override ‘M’
Manual
Override
Option
"G"
Manual
O
verride ‘M’
10 SIZE
12 SIZE
Option
"B"
Option
"M"
Option
"B"
Option
"M"
Manual Override
"M" and "B"
Option for Three-Position HyPerformance™ Solenoid Valves, Detented
Manual
Override
Option
"T"
Manual Override "T" Option for HPV Electro-Proportional Valves
Sizes: -20, -21, -30, -31 (for -12 cavities)
Operation of Manual Override: To override, from neutral push knob down slightly, rotate 90° counterclockwise and pull to activate
coil #1(S1) function. Rotate an additional 90° counterclockwise to engage detent.
From neutral push down knob completely to activate coil #2 (S2) function. Rotate 90° clockwise to engage detent.
Operation of Manual Override: Push and hold to override.
Operation of Manual Override: Pull and hold to override.
Operation of Manual Override: Rotate knob counterclockwise
to activate override function.
Operation of Manual Override: Rotate knob counterclockwise to activate override function.
®
HYDRAFORCE
HYDRAFORCE
.com
®