321
E 7.581.0/03.12
Inline Filter HDF
Inline Filter for
Reversible Flow HDFF
up to 380 l/min, up to 280 (420) bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head and a screw-in lter bowl. HDFF
lters (on request) are suitable for ow
in both directions.
Standard equipment:
port in L-conguration
without bypass valve
connection for a clogging indicator in
lter head
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941
ISO 2942
ISO 2943
ISO 3724
ISO 3968
ISO 11170
ISO 16889
Contamination retention capacities
in g
Betamicron
®
(BN4HC)
HDF/ 3 µm 5 µm 10 µm 20 µm
HDFF
300 26.1 29.3 31.0 32.0
450 52.1 58.7 62.0 63.9
650 85.4 96.1 101.5 104.7
900 112.8 127.0 134.1 138.3
Betamicron
®
(BH4HC)
HDF/ 3 µm 5 µm 10 µm 20 µm
HDFF
300 17.0 16.6 18.3 20.9
450 35.0 34.2 37.6 42.9
650 58.3 57.1 62.8 71.6
900 77.3 75.7 83.1 94.8
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Betamicron
®
(BH4HC): 210 bar
Other ltration ratings on request.
1.10 IMPORTANT INFORMATION
Filter housings must be earthed.
When using electrical clogging
indicators, the electrical power supply
to the system must be switched off
before removing the clogging indicator
connector.
1.3 FILTER SPECIFICATIONS
Symbol for hydraulic systems
300
650
900
450
E 7.581.0/03.12
1.4 SEALS
NBR (= Perbunan)
1.5 INSTALLATION
As inline lter with or without reversible
oil ow
1.6 SPECIAL MODELS AND
ACCESSORIES
Seals in FPM, EPDM
With bypass valve (only HDF lter)
With No-Element valve
(only HDF lter in L-conguration)
With oil drain plug
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524
Lubrication oils DIN 51517, API,
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506
Biodegradable operating uids VDMA
24568 HETG, HEES, HEPG
Fire-resistant uids HFA, HFB, HFC
and HFD
Operating uids with high water
content (>50% water content) on
request
HDF
HDFF
Nominal pressure 280 (420) bar
Fatigue strength 0 to 280 bar (min. 10
6
cycles)
0 to 420 bar (min. 250,000 cycles)
Temperature range -30 °C to +100 °C
(-30 °C to -10 °C: p
max
= 140 bar)
Material of lter head EN-GJS 400-15
Material of lter bowl Steel
Type of clogging indicator VD (differential pressure indication up to
420 bar operating pressure)
Pressure setting of clogging indicator 5 bar for HDF (others on request)
8 bar for HDFF (others on request)
Cracking pressure of bypass only for
HDF lters (optional)
6 bar (others on request)