321
E 7.581.0/03.12
Inline Filter HDF
Inline Filter for
Reversible Flow HDFF
up to 380 l/min, up to 280 (420) bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head and a screw-in lter bowl. HDFF
lters (on request) are suitable for ow
in both directions.
Standard equipment:
port in L-conguration
without bypass valve
connection for a clogging indicator in
lter head
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941
ISO 2942
ISO 2943
ISO 3724
ISO 3968
ISO 11170
ISO 16889
Contamination retention capacities
in g
Betamicron
®
(BN4HC)
HDF/ 3 µm 5 µm 10 µm 20 µm
HDFF
300 26.1 29.3 31.0 32.0
450 52.1 58.7 62.0 63.9
650 85.4 96.1 101.5 104.7
900 112.8 127.0 134.1 138.3
Betamicron
®
(BH4HC)
HDF/ 3 µm 5 µm 10 µm 20 µm
HDFF
300 17.0 16.6 18.3 20.9
450 35.0 34.2 37.6 42.9
650 58.3 57.1 62.8 71.6
900 77.3 75.7 83.1 94.8
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Betamicron
®
(BH4HC): 210 bar
Other ltration ratings on request.
1.10 IMPORTANT INFORMATION
Filter housings must be earthed.
When using electrical clogging
indicators, the electrical power supply
to the system must be switched off
before removing the clogging indicator
connector.
1.3 FILTER SPECIFICATIONS
Symbol for hydraulic systems
300
650
900
450
E 7.581.0/03.12
1.4 SEALS
NBR (= Perbunan)
1.5 INSTALLATION
As inline lter with or without reversible
oil ow
1.6 SPECIAL MODELS AND
ACCESSORIES
Seals in FPM, EPDM
With bypass valve (only HDF lter)
With No-Element valve
(only HDF lter in L-conguration)
With oil drain plug
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524
Lubrication oils DIN 51517, API,
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506
Biodegradable operating uids VDMA
24568 HETG, HEES, HEPG
Fire-resistant uids HFA, HFB, HFC
and HFD
Operating uids with high water
content (>50% water content) on
request
HDF
HDFF
Nominal pressure 280 (420) bar
Fatigue strength 0 to 280 bar (min. 10
6
cycles)
0 to 420 bar (min. 250,000 cycles)
Temperature range -30 °C to +100 °C
(-30 °C to -10 °C: p
max
= 140 bar)
Material of lter head EN-GJS 400-15
Material of lter bowl Steel
Type of clogging indicator VD (differential pressure indication up to
420 bar operating pressure)
Pressure setting of clogging indicator 5 bar for HDF (others on request)
8 bar for HDFF (others on request)
Cracking pressure of bypass only for
HDF lters (optional)
6 bar (others on request)
E 7.581.0/03.12
322
0450 D 010 BN4HC /-V
Size
0300, 0450, 0650, 0900
Type
D
Filtration rating in µm
BN4HC, BH4HC: 003, 005, 010, 020
Filter material
BN4HC, BH4HC
Supplementary details
V (for descriptions, see point 2.1)
2.3 REPLACEMENT CLOGGING INDICATOR VD 5 D . X /-L24
Type
VD differential pressure indicator up to 420 bar operating pressure
Pressure setting
5 standard 5 bar (for HDF lters)
others on request
8 standard 8 bar (for HDFF lters)
Type of clogging indicator (see Point 2.1)
Modication number
X the latest version is always supplied
Supplementary details
V (for descriptions, see point 2.1)
HDF BN/HC 450 O L E 10 D 1 . X /-L24
Filter type
HDF or HDFF (HDFF on request)
Filter material
BN/HC Betamicron
®
(BN4HC)
BH/HC Betamicron
®
(BH4HC)
Size of lter or element
HDF/HDFF: 300, 450, 650, 900
Operating pressure
O 280 bar
Head type
L Flow path in L-conguration (standard version)
Type and size of connection
Type Connection
300 450 650 900
D G 1
E G1 ¼
F G1 ½
Filtration rating in µm
BN/HC, BH/HC: 3, 5, 10, 20
Type of clogging indicator
Y plastic blanking plug in indicator port
A steel blanking plug in indicator port
BM visual
for other clogging indicators,
C electrical
see brochure no. 7.050../..
D visual and electrical
Type code
1
Modication number
X the latest version is always supplied
Supplementary details
B. bypass cracking pressure (e.g. B6 = 6 bar); without details = without bypass valve
L... light with appropriate voltage (24, 48, 110, 220 Volt) only for clogging
LED 2 light-emitting diodes up to 24 Volt indicators type "D"
NEV No Element valve (only for HDF lters in L-conguration)
SO184 pressure release/oil drain screw
V FPM seals
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
2.2 REPLACEMENT ELEMENT
323
E 7.581.0/03.12
3. FILTER CALCULATION /
SIZING
The total pressure drop of a lter at a
certain ow rate Q is the sum of the
housing p and the element p and is
calculated as follows:
p
total
=∆p
housing
+∆p
element
p
housing
= (see Point 3.1)
p
element
= Q
SK*
viscosity
1000 30
(*see Point 3.2)
For ease of calculation, our Filter
Sizing Program is available on request
free of charge.
NEW: Sizing online at www.hydac.com
3.1 p-Q HOUSING CURVES BASED
ON ISO 3968
The housing curves apply to mineral oil
with a density of 0.86 kg/dm³ and
a kinematic viscosity of 30 mm²/s.
In this case, the differential pressure
changes proportionally to the density.
HDF
p [bar]
Q [l/min]
HDF with NEV
p [bar]
Q [l/min]
3.2 GRADIENT COEFFICIENTS (SK) FOR FILTER ELEMENTS
The gradient coefcients in mbar/(l/min) apply to mineral oils with a kinematic
viscosity of 30 mm²/s. The pressure drop changes proportionally to the change in
viscosity.
BH4HC
3 µm 5 µm 10 µm 20 µm
300 16.0 8.9 7.1 3.3
450 7.8 4.3 3.4 1.6
650 4.7 2.6 2.1 1.0
900 3.5 2.0 1.6 0.7
p [bar]
Q [l/min]
BN4HC: 300
p [bar]
Q [l/min]
BN4HC: 450
p [bar]
Q [l/min]
BN4HC: 650
p [bar]
Q [l/min]
BN4HC: 900
E 7.581.0/03.12
324
NOTE
The information in this brochure relates to the operating conditions and
applications described.
For applications or operating conditions not described, please contact the relevant
technical department.
Subject to technical modications.
HYDAC FILTERTECHNIK GMBH
Industriegebiet
D-66280 Sulzbach/Saar, Germany
Tel: 0 68 97 / 509-01
Fax: 0 68 97 / 509-300
Internet: www.hydac.com
E-Mail: lter@hydac.com
HDF/
HDFF
h1 Weight incl.
element [kg]
Volume of
pressure chamber [l]
300 246 11.2 0.8
450 339 13.1 1.4
650 460 16.2 2.1
900 558 21.5 2.7
4. DIMENSIONS
blanking plug SW27
or
clogging indicator is
possible
outlet
inlet
SW32
M10x18 deep
Ød3 t1
G1 18
G1 1/4 20
G1 1/2 22