393
E 7.551.10/03.12
Pressure Filter for
Manifold Mounting DFP
and for Reversible Flow DFPF
up to 600 l/min, up to 315 bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head and a screw-in lter bowl. DFPF
lters are suitable for ow in both
directions.
Standard equipment:
connection for a clogging indicator
two-piece bowl for DFP/F 990 and
above (optional for DFP/F 660 and
above)
drain screw with pressure relief
(standard for DFP/F 330 and above)
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941
ISO 2942
ISO 2943
ISO 3724
ISO 3968
ISO 11170
ISO 16889
Contamination retention capacities in g
Betamicron
®
(BN4HC)
DFP/F 3 µm 5 µm 10 µm 20 µm
60 6.5 7.3 7.8 8.0
110 13.8 15.5 16.4 16.9
140 18.1 20.3 21.5 22.2
160 19.8 22.2 23.5 24.3
240 32.3 36.3 38.4 39.6
280 70.6 79.3 83.9 86.6
330 47.2 53.1 56.1 57.9
500 76.9 86.5 91.5 94.4
660 102.2 114.9 121.5 125.4
990 154.5 173.7 183.7 189.5
1320 209.9 236.0 249.6 257.5
Betamicron
®
(BH4HC)
DFP/F 3 µm 5 µm 10 µm 20 µm
60 4.6 4.5 5.0 5.7
110 10.1 9.9 10.9 12.4
140 13.3 13.0 14.3 16.3
160 12.9 12.6 13.9 15.9
240 21.6 21.1 23.2 26.5
280 48.1 47.1 51.8 59.1
330 34.6 33.9 37.2 42.5
500 57.5 56.3 61.8 70.5
660 76.8 75.2 82.6 94.3
990 111.8 109.4 120.2 137.2
1320 153.8 150.7 165.5 188.8
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Betamicron
®
(BH4HC): 210 bar
Wire mesh (W): 20 bar
Stainless steel bre (V): 210 bar
1.4 SEALS
NBR (= Perbunan)
1.5 INSTALLATION
As pressure lter for manifold block
mounting, with or without reversible oil
ow
1.6 SPECIAL MODELS AND
ACCESSORIES
Bypass valve built into the head
Seals in FPM, EPDM
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524
Lubrication oils DIN 51517, API,
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506
Biodegradable operating uids VDMA
24568 HETG, HEES, HEPG
Fire-resistant uids HFA, HFB, HFC
and HFD
Operating uids with high water
content (>50% water content) on
request
1.10 IMPORTANT INFORMATION
Filter housings must be earthed.
When using visual clogging indicators,
the BM version (visual with manual
reset) only should be used.
When using electrical clogging
indicators, the electrical power supply
to the system must be switched off
before removing the clogging indicator
connector.
1.3 FILTER SPECIFICATIONS
Nominal pressure 315 bar
Fatigue strength At nominal pressure 10
6
cycles
from 0 to nominal pressure
Temperature range -30 °C to +100 °C
(-30 °C to -10 °C: p
max
= 157.5 bar)
Material of lter head EN-GJS 400-15
Material of lter bowl Steel
Type of clogging indicator VD (differential pressure measurement
up to 420 bar operating pressure)
Pressure setting of the clogging indicator 5 bar (others on request)
Bypass cracking pressure (optional) 6 bar (others on request)
DFP/F
60
DFP/F
140
DFP/F
160
DFP/F
240
DFP/F
280
DFP/F
330
DFP/F
500
DFP/F
660 1.X
DFP/F
660 2.X
DFP/F
990
DFP/F
1320
DFP/F
110
E 7.551.10/03.12
Symbol for hydraulic systems
DFP DFPF