E 7.116.4/03.12
Return Line Filter RF
up to 15000 l/min, up to 25 bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
housing and a threaded cover plate.
Standard equipment:
with bypass valve in the element. For
RF 450/580 the bypass valve is built
into the cover plate as standard.
connection for a clogging indicator
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941
ISO 2942
ISO 2943
ISO 3724
ISO 3968
ISO 11170
ISO 16889
Contamination retention capacities
in g
Betamicron
®
(BN4HC)
RF Elements 3 µm 5 µm 10 µm 20 µm
30 1x0030R 2.6 2.9 3.5 4.0
60 1x0060R 5.7 6.3 7.6 8.6
110 1x0110R 12.0 13.3 16.0 18.1
160 1x0160R 18.6 20.7 24.9 28.1
240 1x0240R 29.3 32.5 39.1 44.2
330 1x0330R 38.4 42.6 51.2 57.9
450 1x0450R 49.1 54.4 65.5 74.1
580 1x0580R 124.7 138.2 166.3 188.1
660 1x0660R 87.1 96.5 116.1 131.3
950 1x0950R 130.0 144.1 173.3 196.1
1300 1x1300R 181.0 200.7 241.4 273.1
2500 3x0850R 336.3 372.6 448.5 507.3
4000 5x0850R 560.5 621.0 747.5 845.5
5200 4x1300R 724.0 802.8 965.6 1092.4
6500 5x1300R 905.0 1003.5 1207.0 1365.5
7800 6x1300R 1086.0 1204.2 1448.4 1638.6
15000 10x1300R 1810.0 2007.0 2414.0 2731.0
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Paper (P/HC): 10 bar
Wire mesh (W/HC): 20 bar
Stainless steel bre (V): 210 bar
Betamicron
®
/Aquamicron
®
(BN4AM): 10 bar
Aquamicron
®
(AM): 10 bar
1.4 SEALS
NBR (= Perbunan)
1.5 INSTALLATION
As tank-top or inline lter.
RF 450 and 580 are also suitable for
horizontal installation (with check
valve).
1.6 SPECIAL MODELS AND
ACCESSORIES
On request
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524
Lubrication oils DIN 51517, API,
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506
Biodegradable operating uids VDMA
24568 HETG, HEES, HEPG
Fire-resistant uids HFA, HFB, HFC
and HFD
Operating uids with high water
content (>50% water content) on
request
1.10 IMPORTANT INFORMATION
Filter housings must be earthed.
When using electrical clogging
indicators, the electrical power supply
to the system must be switched off
before removing the clogging indicator
connector.
Filters must be exibly mounted and
not xed rigidly to the oor or used as
a pipe support.
1.3 FILTER SPECIFICATIONS
Nominal pressure RF 30, 2500 to 15000: 10 bar
RF 450 and 580: 16 bar
RF 60 to 1300: 25 bar
Temperature range -10 °C to +100 °C
Material of lter housing and cover plate RF 30: PA 66
RF 60 to 580: Aluminium
RF 660 to 1300: EN-GJS-400-15
RF 2500 to 15000: Welded steel
Type of clogging indicator VR Connection thread G ½
(return line indicator up to 25 bar
operating pressure)
VM Differential pressure indicator
only for RF 450 and 580
Pressure setting of clogging indicator 2 bar (others on request)
Bypass cracking pressure 3 bar (others on request)
Symbol for hydraulic systems
RF
30
E 7.116.4/03.12
RF 2500 RF 4000 RF 5200 RF 6500-7800 RF 15000
RF
60
RF
110
RF
160
RF
240
RF
330
RF
450
RF
950
RF
580
RF
1300
RF
660
VA = clogging indicator