E 5.972.1/12.10
457
model code
WK10P-01M-C-N-24DG
Designation
Directional spool valve UNF
Cavity 10
Function code P
Type 01 = standard
Option
Omission = No Option
M = Manual Override
BodyandPorts
C = Cartridge Only
SB4 = 1/2 BSP ports, steel body
AB4 = 1/2 BSP ports, aluminium body
Seals
N = NBR
V = FKM
CoilVoltage
DC
12 = 12 V DC
24 = 24 V DC
AC (internally full wave rectied)
115 = 115 V AC
230 = 230 V AC
other voltages on request
CoilConnector
DC: DG = DIN Connector to EN 175301-803
DK = Kostal threaded connection M27x1
DL = Leadwires (2) - 457mm, (18") long
DN = Deutsch connector, 2 pole
DT = AMP Junior Timer, 2-pole, radial
AC: AG = DIN Connector to EN 175301-803
other connection types on request
dimensions
millimeter (inch)
Subject to technical modications
cavity
FC10-4
Formtools
Tool PartNo.
Rougher FC10-4 176174
Finisher FC10-4 176175
millimeter (inch)
Subject to technical modications
1 hex torque 5
+2
Nm
After loosening
mounting nut, coil
can be rotated
through 360° and
removed.
1 hex torque 45
+10
Nm
Manual override, Option 'M'
After removing mounting
nut, manual operation
is possible by twisting
button anti-clockwise.
torque 4
+2
Nm
thick
perFormance
Pressure drop
Flow rate
Measured at ν = 34 mm
2
/s (158 SUS)
T
Oil
= 46°C (115 °F)
Flow rate
Pressure
PRESSURE DROP
OPERATING LIMITS
Standardmodels
Modelcode PartNo.
WK10P-01-C-N-24DG 3098533
WK10P-01-C-N-230AG 3098534
Inlineconnectionhousings
Code PartNo. Material Ports Pressure
FH104-SB4 3037784 Steel, zinc-plated 1/2 BSP 350 bar
FH104-AB4 3038097 Aluminium, clear anodized 1/2 BSP 245 bar
HYDACFluidtechnikGmbH
Justus-von-Liebig-Str.
D-66280Sulzbach/Saar
Tel: 0 68 97 /509-01
Fax: 0 68 97 /509-598
E-Mail: utec@hydac.com
NOTE
The information in this brochure relates to
the operating conditions and applications
described. For applications or operating
conditions not described, please contact the
relevant technical department.
Subject to technical modications.
other models on request
other housings on request
without M.O.