E 5.967.1.0/12.10
162
Flow Divider / Combiner
SAE 16-Cartridge – 350 bar
ST16-01
150 l/min
350 bar
In dividing mode, the ST16 will divert
input ow, according to the specied
ratio, from port 3 to ports 2 and 4.
In combining mode, input ow will be
combined, according to the specied
ratio, from ports 2 and 4 into port 3.
Port 1 is not used and should be
blanked.
Features
All surfaces zinc-plated and corrosion proof
All valve parts made of high-strength steel with hardened and ground
components to ensure minimal wear and to extend service life
Rigid design using one-piece body minimizes the effect of eccentricity
and maximizes reliability
High dividing & combining accuracy
Wide ow range down to 25% of nominal ow rating
Low pressure drop
Can be used for differential lock in transmission applications
Synchronizing ow in the dividing and combining mode in motor
and cylinder applications
Compact design
Function
speciFications
Operating pressure: 350 bar
Nominal ow: 150 l/min
Inlet ow: 90 l/min Model Code 1212
115 l/min Model Code 1515
150 l/min Model Code 2020
Accuracy: see performance chart
Media operating temp. range: -20 °C to +120 °C
Fluids: Mineral-based or synthetics with
lubricating properties
Viscosity: 7.4 to 420 cSt
Filtration: Class 21/19/16 according to ISO 4406
or cleaner
Material: Valve body: carbon steel
Spool: carbon steel
Sealings: NBR (standard)
FKM (optional)
Cavity: FC16-4 (Port 1 is not used,
blocked by blind cavity)
Weights: 446 g
(Port 1 is not used)