E 5.962.1/12.10
461
Model code
WK10R-01M-C-N-24DG
Basicmodel
Directional spool valve UNF
Cavity 10
Function code R
Type 01 = standard
Option
Omission = No Option
M = Manual Override
Body&Ports
C = Cartridge only
SB4 = 1/2 BSP ports, steel body
AB4 = 1/2 BSP ports, aluminium body
Seals
N = NBR
V = FKM
CoilVoltage
DC
12 = 12 V DC
24 = 24 V DC
AC (internally full wave rectied)
24 = 24 V AC
230 = 230 V AC
CoilConnector
DC: DG = DIN Connector to EN 175301-803
DK = Kostal threaded connection M27x1
DL = Leadwires (2) - 457mm, (18") long
DN = Deutsch connector, 2 pole
DT = AMP Junior Timer, 2-pole, radial
AC: AG = DIN Connector to EN 175301-803
other connection types on request
diMensions
ow
Inlineconnectionhousings
Code PartNo. Material Ports Pressure
FH104-SB4 3037784 Steel, zinc-plated 1/2 BSP 350 bar
FH104-AB4 3038097 Aluminium, clear anodized 1/2 BSP 245 bar
millimeter (inch)
Subject to technical modications
cavity
FC10-4
Formtools
Tool PartNo.
Rougher FC10-4 176174
Finisher FC10-4 176175
Manual Override, Option 'M'
with HNBR-Rubber Cap
thick
After loosening mounting nut,
coil can be rotated through
360° and removed
Standardmodels
Modelcode PartNo.
WK10R-01-C-N-24DG 3097259
WK10R-01-C-N-230AG 3097260
Torque 4
+2
Nm
whithout M.O.
25.5 (1) Hex Torque 45
+10
Nm
operating liMits
measured at ν = 34 mm
2
/s, T
Oil
= 46 °C
operating pressure
millimeter (inch)
Subject to technical modications
perForMance
pressure drop
ow rate
measured at ν = 34 mm
2
/s, T
Oil
= 46 °C
other models on request
other housings on request
HYDACFluidtechnikGmbH
Justus-von-Liebig-Str.
D-66280Sulzbach/Saar
Tel: 0 68 97 /509-01
Fax. 0 68 97 /509-598
E-Mail: utec@hydac.com
NOTE
The information in this brochure relates to
the operating conditions and applications
described. For applications or operating
conditions not described, please contact the
relevant technical department.
Subject to technical modications.