E 5.961.1/12.10
434
4/2-Solenoid
Directional Valve
SAE 10-Cartridge - 350 bar
WK10X-01
SPOOL Type - Direct Operated
32 l/min
350 bar
In the de-energized mode, the valve
allows ow from port 3 to 2 or 2 to 3 and
from port 4 to 1 or 1 to 4.
When energized, the valve allows ow
from port 3 to 4 or 4 to 3 and from port 2
to 1 or 1 to 2.
Function
speciFications
Operating pressure: 350 bar
Nominal ow: 32 l/min
Internal leakage: 100 cm³/min max at 250 bar and 34 m/s
Media operating temp. range: -20 °C to +120 °C
Ambient temp. range: -20 °C to +60 °C
Fluids: Hydraulic oil to DIN 51524 part 1 and 2
Viscosity: 7.4 to 420 mm²/s
Filtration: Class 21/19/16 according to ISO 4406
or cleaner
Material: Valve body: carbon steel
Spool: carbon steel
Seals: NBR (standard)
FKM (optional)
Coil: Steel/Polyamide
Cavity: FC10-4
Weights: Valve complete: 0.48 kg
Coil only: 0.23 kg
Current draw at 20 °C (68 °F): 2.22 A at 12 V DC
1.13 A at 24 V DC
Minimum pull-in voltage: 85 % of nominal
Coil duty rating: Continuous up to 115% of nominal
voltage at 60 °C ambient temperature
Type of voltage: DC solenoid, AC voltage is rectied
using a bridge rectier built into the coil.
Features
All surfaces zinc-plated and corrosion-proof
All valve parts made of high-strength steel with hardened and ground
components to ensure minimal wear and extended service life
Coil seals protect the solenoid system
Wide variety of coils and connectors available
Rigid design using one-piece body minimizes the effect of eccentricities in cavity
and maximizes reliability
Excellent switching performance by high power HYDAC solenoid
Low pressure drop due to CFD optimized ow path
E 5.961.1/12.10
435
perFormance
model code
WK10X-01M-C-N-24DG
Basicmodel
Directional spool valve UNF
Cavity 10
Function code X
Type 01 = standard
Option
Omission = No Option
M = Manual Override
Body&Ports*
C = Cartridge only
SB4 = 1/2 BSP ports, steel body
AB4 = 1/2 BSP ports, aluminium body
Seals
N = NBR
V = FKM
CoilVoltage
DC
12 = 12 V DC
24 = 24 V DC
AC (internally full wave rectied)
24 = 24 V AC
115 = 115 V AC
230 = 230 V AC
other voltages on request
CoilConnector
DC: DG = DIN Connector to EN 175301-803
DK = Kostal threaded connection M27x1
DL = Leadwires (2) - 457 mm (18") long
DN = Deutsch connector, 2 pole
DT = AMP Junior Timer, 2-pole, radial
AC: AG = DIN Connector to EN 175301-803
other connection types on request
dimensions
pressure drop
ow
Inlineconnectionhousings
Code PartNo. Material Ports Pressure
FH104-SB4 3037784 Steel, zinc-plated 1/2 BSP 420 bar
FH104-AB3 3038097 Aluminium, clear anodized 1/2 BSP 245 bar
other housings on request
millimeter (inch)
Subject to technical modications
cavity
FC10-4
Formtools
Tool PartNo.
Rougher FC10-4 176174
Finisher FC10-4 176175
measured at ν = 34 mm²/s, T
Oil
= 46 °C
Manual Override, Option 'M'
thick
After removing mounting
nut, manual operation is
possible by twisting but-
ton counterclockwise.
Standardmodels
Modelcode PartNo.
WK10X-01-C-N-24DG 3079851
WK10X-01-C-N-230AG 3096314
other models on request
Torque 4
+2
Nm
whithout M.O.
1 Hex Torque 45
+10
Nm
operating limits
measured at ν = 34 mm²/s, T
Oil
= 46 °C
operating pressure
ow rate
Torque 4
+2
Nm
After loosening
mounting nut,
coil can be rotated
through 360°
and removed
millimeter (inch)
Subject to technical modications
HYDACFluidtechnikGmbH
Justus-von-Liebig-Str.
D-66280Sulzbach/Saar
Tel: 0 68 97 /509-01
Fax: 0 68 97 /509-598
E-Mail: utec@hydac.com
NOTE
The information in this brochure relates to
the operating conditions and applications
described. For applications or operating con-
ditions not described, please contact
the relevant technical department.
Subject to technical modications.