E 5.948.1/12.10
352
2/2 Solenoid Directional Valve
Cartridge Valve - 350 bar
SEAT Type – Pilot Operated
Normally Open (Reverse Flow)
WSM06020YR-01
up to 40 l/min
up to 350 bar
When the solenoid coil is not energized,
there is free ow through the valve in
both directions.
When the solenoid coil is energized, the
valve is closed from port 2 to port 1.
In the reverse direction there is free ow
through the valve when the pressure
force on the spool exceeds the solenoid
force (approx. 9 to 20 bar).
GENERAL
Excellent switching performance by high power HYDAC solenoid
All valve parts made of high-strength steel with hardened and ground compon-
ents to ensure minimal wear and extended service life
Rigid design by one-piece-body minimizes the effect of eccentricity and maximi-
zes reliability
All surfaces zinc-plated and corrosion-proof
Waterproof design standard
Wide variety of connectors available
Low pressure drop by CFD optimized ow-path
FUNCTION
SPECIFICATIONS
Operating pressure: max. 350 bar
Flow rate: max. 40 l/min
Internal leakage: leakage-free
Temperature range of operating uid: -20 °C to +120 °C
Ambient temperature range: -20 °C to +60 °C
Type of voltage: DC solenoid,
AC voltage is rectied using a
bridge rectier built into the coil
Nominal voltage (at 20 °C): 1.5 A at 12 V DC
0.8 A at 24 V DC
Voltage tolerance: ±15% of nominal voltage
Switch-on time: continuous up to 115 % of nominal
voltage at 60 °C ambient temperature
Switching time: on: approx. 50 ms
off: approx. 35 ms
Operating uid: hydraulic oil to DIN 51524 Part 1 and 2
Viscosity range: 10 mm²/s to 420 mm²/s is recommended
Filtration: Permissible contamination level
of the operating uid to
ISO 4406 Class 21/19/16 or cleaner
Mounting position: optional
Materials: valve body: high tensile steel
closing elements: hardened and
ground steel
seals: NBR (standard)
FKM (optional)
back-up ring in PTFE
Cavity: 06020
Weight: valve complete: 0.33 kg
coil only: 0.19 kg
E 5.948.1/12.10
353
DIMENSIONS
CAvITy
06020
After loosening knurled nut, coil can be
rotated through 360° and removed.
Manual override, with HNBR-rubber cap.
Torque 4
+2
Nm
24 HEX
Torque 25
+5
Nm
Subject to
technical modications.
Subject to
technical modications.
tting depth
Cartridge form tools
Tool Stock no.
Countersink (shank MK3) 170033
Reamer (shank MK2) 1000768
PRESSURE DROP
MODEL CODE
WSM 06020 YR - 01 M - C - N - 24 DG
Designation
(Directional seat valve, metric)
Cavity
06020 = 2-way cavity
Function code
Type
01 = standard model
Manual override
no details = without manual override
M = manual override
Body and ports
C = cartridge only
Seals
N = NBR
V = FKM
Nominal voltage for actuating solenoid
DC voltages
10 = 10 V DC
12 = 12 V DC
24 = 24 V DC
36 = 36 V DC
48 = 48 V DC
110 = 110 V DC only with plug to EN 175301-803
AC voltages (bridge rectier built into the coil)
24 = 24 V AC
115 = 115 V AC
230 = 230 V AC
other voltages on request
Electrical connection types of the actuating solenoid
DC: DG = plug to EN 175301-803
DL = with 2 ying leads, 457 mm long
0.75 mm
2
cable cross-section
DW = Weather Pack plug no. 12010973 on 2 leads, 241 mm long
DT = AMP Junior Timer, 2-pole, radial
DK = KOSTAL threaded connection M27x1
AC: AG = plug to EN 175301-803
other connection types on request
Pressure drop [bar]
Flow rate [l/min]
Measured at n = 34 mm²/s
T
Oil
= 46 °C
Inline connection housings
Code Stock no. Material Ports
R06020-01X-01 275266 Steel, zinc-plated G 3/8
For other connection housings, see brochure no. E 5.252.
"Connection Housings for Cartridge Valves".
non-energized
non-energized
Standard models
Model code Stock no.
WSM06020YR-01-C-N-24DG 3056228
WSM06020YR-01-C-N-230AG 3056226
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str.
D-66280 Sulzbach/Saar
Tel: 0 68 97 /509-01
Telefax. 0 68 97 /509-598
E-Mail: utec@hydac.com
NOTE
The information in this brochure relates to
the operating conditions and applications
described.
For applications or operating conditions
not described, please contact the relevant
technical department.
Subject to technical modications.
E 5.948.1/07.04