E .0/12.10
354
2/2 Solenoid Directional Valve
Poppet Type - Pilot Operated
Normally Open (Reverse Flow)
Cartridge Valve - 350 bar
WSM10120YR-01
In the de-energized mode, the valve
allows ow in both directions.
When energized, the valve blocks ow
from 2 to 1. In this mode the valve will
allow ow from 1 to 2 after the hydraulic
force overcomes the solenoid force of
2.5 to 10 bar.

All surfaces zinc-plated and corrosion-proof
All valve parts made of high-strength steel with hardened and ground
components to ensure minimal wear and extended service life
Waterproof design standard
Wide variety of connectors available
Rigid design using one-piece body minimizes the effect of eccentricity and
maximizes reliability
Excellent switching performance by high power HYDAC solenoid
Low pressure drop by CFD optimized ow-path


Operating pressure: Max. 350 bar
Nominal ow: Max. 75 l/min
Internal leakage: Leakage-free
Media operating temp. range: -20 °C to +120 °C
Ambient temperature range: -20 °C to +60 °C
Type of voltage: DC solenoid, AC voltage is rectied
using a bridge rectier built into the coil
Current draw at 20 °C: 1.5 A at 12 V DC
0.8 A at 24 V DC
Voltage tolerance: +/-15% of nominal voltage
Coil duty rating: Continuous up to 115% of nominal
voltage at 60 °C ambient temperature
Response time: Energized: approx. 60 ms
De-energized: approx. 20 ms
(typical 24 V DC-coil)
Fluids: Hydraulic oil to DIN 51524 Part 1 and 2
Viscosity: 10 mm²/s to 420 mm²/s is recommended
Filtration: Permissible contamination level
of the operating uid to ISO 4406
class 21/19/16 or cleaner
Installation: Optional
Materials: Valve body: high tensile steel
Closing elements: hardened and
ground steel
Seals: NBR (standard)
FKM (optional)
back-up ring in
PTFE
Coil: Steel/Polyamide
Cavity: 10120
Weights: Valve complete: 0.370 kg
Coil only: 0.190 kg
up to 75 l/min
up to 350 bar
E .0/12.10
355




(Directional poppet valve, metric)

10120 = 2-way cavity


01 = standard

omission = no option
M = manual override

C = cartridge only

N = NBR
V = FKM

DC voltages
12 = 12 V DC
24 = 24 V DC
AC voltages (internally full wave rectied)
24 = 24 V AC
115 = 115 V AC
230 = 230 V AC
other voltages on request

 DG = DIN connector to EN 175301-803
DL = Leadwires (2) - 457 mm, 18" long
DW = Weather Pack connector on leadwires - 241mm (9.5") long
DT = AMP Junior Timer, 2-pole, radial
DK = KOSTAL threaded connection M27x1
 AG = DIN connector to EN 175301-803
other connection types on request


10120

 
Rougher (shank MK3) 170418
Finisher (shank MK2) 1014206
millimeter
subject to technical modications
Measured at n = 33 mm²/s T
Oil
= 46 °C

   
R10120-01X-01 395234 Steel, zinc-plated G 1/2
millimeter
subject to technical modications

 
WSM10120YR-01-C-N-24DG 3179040
WSM10120YR-01-C-N-230AG 3179039
Pressure drop [bar]
Flow rate [l/min]

Justus-von-Liebig-Str.

Tel: 0 68 97 /509-01
Telefax. 0 68 97 /509-598
E-Mail: utec@hydac.com

The information in this brochure relates to
the operating conditions and applications
described.
For applications or operating conditions not de-
scribed, please contact the relevant technical
department.
Subject to technical modications.
After loosening nut,
coil can be turned through 360°
and removed
Manual override with
HNBR rubber cap
hex. SW 27 Torque 45
+10
Nm
Torque 4
+2
Nm
tting depth
For other connection housings, see brochure no. E 5.252. "Connection Housings for Cartridge Valves".
2 1
de-energized
1 2
de-energized