E 5.174.12/11.13
280
Hose Burst Valve
Direct-Acting
Flat Seat Valve,
Cartridge – 350 bar
RBE 1/4 to 3/4
FEATURES
z Hose burst valves for direct installation in cylinders, lines and control blocks
z Highly reliable thanks to fast response
z Unauthorized adjustment not possible once installed
z Choice of four sizes for optimum adaptability to the system
z Different ow rate settings available as an option
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal ow: RBE1/4 up to max. 25 l/min
RBE3/8 up to max. 50 l/min
RBE1/2 up to max. 75 l/min
RBE3/4 up to max. 150 l/min
Media operating temperature range: min. -20 °C to max. +100 °C
Ambient temperature range: min. -20 °C to max. +100 °C
Operating uid: Hydraulic oil to DIN 51524 Part 1 and 2
Viscosity range: min. 2.8 mm²/s to max. 800 mm²/s
Filtration: Class 21/19/16 according to ISO 4406 or
cleaner
MTTF
d
: 150 years (see "Conditions and
instructions for valves" in brochure 5.300)
Installation: No orientation restrictions, preferably
horizontal
Materials: Valve body: steel
Weight: RBE1/4 = 0.009 kg
RBE3/8 = 0.016 kg
RBE1/2 = 0.031 kg
RBE3/4 = 0.057 kg
The hose burst valve RBE is a ow
operated at seat valve which prevents
uncontrolled movement in the consumer in
the event of a hose burst. The hose burst
valve is open in the normal position and
allows ow in both directions. If the pre-set
actuating ow rate is exceeded as a result
of a hose burst, for example, the valve
quickly closes and blocks the ow from
port 1 to port 2.
Caution:
The actuating ow rate should be at least
20% higher than the highest ow rate in the
system, to prevent the valve reacting too
sensitively! Due to the effects of acceleration
and inertia, the valve should be replaced
after a hose burst.
Up to 150 l/min
Up to 350 bar
FUNCTION
Closing
element
Consumer
being protected
Valve seat
Spring