E .4/12.10
192
Flow Control Valves
Direct Acting and
Flow Control Valves
with Reverse Check
Manifold Mounted 350 bar
DVP, DRVP 06 to 40

z For regulating the speed of loads
z For ne adjustment and shut-off of the ow
z For system-related damping in hydraulic circuits
z To release pressure from accumulator systems
z As an emergency drain for lowering a load
z High level of safety is achieved through patented spindle safety mechanism
z A set-screw locks the setting
z Choice of nine sizes ensures best possible adaptability to the system
z All valve parts made of high-strength steel with hardened and ground components to
ensure minimal wear and extended service life
z Optional zinc-plated version available (up to size 12)

Operating pressure: max. 350 bar
Nominal ow: DVP, DRVP-06 max. 20 l/min
DVP, DRVP-08 max. 50 l/min
DVP, DRVP-10 max. 60 l/min
DVP, DRVP-12 max. 90 l/min
DVP, DRVP-16 max. 180 l/min
DVP, DRVP-20 max. 300 l/min
DVP, DRVP-25 max. 300 l/min
DVP, DRVP-30 max. 300 l/min
DRVP-40 max. 300 l/min
Cracking pressure: (of DRVP): 0.5 bar
Media operating temperature range: min. -20 °C to max. +80 °C
Ambient temperature range: min. -20 °C to max. +80 °C
Fluid: Hydraulic oil to DIN 51524 Part 1 + 2
Viscosity: min. 2.8 mm²/s to max. 800 mm²/s
Filtration: Class 21/19/16 to ISO 4406
or cleaner
MTTF
d
: 150 years
Installation: No orientation restrictions, preferably
horizontal
Materials: Valve body: steel
Piston: hardened and
ground steel
Seals: FKM (standard)
Back-up rings: PTFE
Weight: DVP 06 = 0.2 kg DRVP 06 = 0.3 kg
DVP 08 = 0.4 kg DRVP 10 = 0.8 kg
DVP 10 = 0.6 kg DRVP 12 = 1.1 kg
DVP 12 = 1.0 kg DRVP 16 = 2.5 kg
DVP 16 = 1.7 kg DRVP 25 = 6.7 kg
DVP 20 = 3.6 kg DRVP 30 = 3.9 kg
DVP 25 = 5.5 kg DRVP 40 = 17.5 kg
DVP 30 = 7.5 kg
The DVP is a manifold mounted ow
control valve which controls the ow
rate by adjusting the constriction of the
cross-section. The ow rate is therefore
dependent on the pressure differential and
viscosity. Starting with the control spindle
in the fully closed position, the ow rate
increases according to the relevant curve
as the number of turns of the control knob
is increased. The ow is controlled in
both directions. The DRVP is a manifold
mounted ow control valve which allows
the same ne ow adjustment, but in one
direction only. Unrestricted ow in the
reverse direction is via the built-in check
valve.
Up to 300 l/min
Up to 350 bar

DVP
Control knob
Control knob
Set-screw
Set-screw
Control spindle
Control spindle
Housing
Housing Valve seat Closing cone Spring
Throttle opening
Throttle opening
DRVP
193
E .4/12.10



Flow control valve DVP
Flow control valve with check valve DRVP

06, 08, 10, 12, 16, 20, 25, 30

01 = standard (housing phosphated,
seals FKM)
Other types on request:
12 = housing nickel-plated, ne throttle spindle in steel,
with protective dome nut - adjustment with tool
(not for size 40)
Other types on request

(determined by manufacturer)

Pressure drops, dependent on ow rate
DVP = ow direction A → B and B → A
DRVP = ow direction A → B
Pressure differential ∆p measured against ow rate
Measured at constant ow setting ν = 54 mm²/s
and T
oil = 36 °C





 
DVP-06-01.X 705351
DVP-08-01.X 705353
DVP-10-01.X 705355
DVP-12-01.X 705357
DVP-16-01.X 705359
DVP-20-01.X 705361
DVP-25-01.X 705363
DVP-30-01.X 705365
DRVP-06-01.X 705777
DRVP-08-01.X 705779
DRVP-10-01.X 705781
DRVP-12-01.X 705783
DRVP-16-01.X 705785
DRVP-20-01.X 705787
DRVP-25-01.X 705789
DRVP-30-01.X 705791
DRVP-40-01.X 705792
Other models on request

 
SEAL KIT 06FPM DV/P DRV/P RVP 555089
SEAL KIT 08FPM DV/P DRV/P DVE RVP SRVR/P 555090
SEAL KIT 10FPM DV/P DRV/P DVE RVP SRVR/P 555091
SEAL KIT 12FPM DV/P DRV/P DVE RVP SRVR/P 555092
SEAL KIT 16FPM DV/P DRV/P DVE RVP SRVR/P 555093
SEAL KIT 20FPM DV/P DRV/P RVP SRVR/P 555094
SEAL KIT 25FPM DV/P DRV/P RVP 555095
SEAL KIT 30FPM DV/P DRV/P RVP 555096
SEAL KIT 40FPM DV/P DRV/P RVP 561456




ow setting in turns
ow setting in turns
ow setting in turns
ow setting in turns

E .4/12.10
194







ow setting in turns
ow setting in turns


closed
View X
control knob with
hex. is standard
for size 20 and
above
SW19 metric
required surface nish on
interface area
open
 A B D E F G H J K M
 63 58 11 6.6 16 24 19.0 35.0 28.5
 79 72 11 6.6 20 29 35.0 47.5 33.5
 84 77 11 6.6 25 29 33.5 51.0 38.0
 99 89 11 6.6 25 38 38.0 75.0 44.5
 113 103 14 9.0 30 38 38.0 76.0 93.5 54.0
 165 148 14 9.0 45 49 47.5 95.0 111.0 60.0
 165 148 18 11.5 45 49 60.0 120.5 143.0 76.0
 170 153 20 14.0 50 49 71.5 143.0 171.0 92.0
 170 153 20 14.0 50 49 67.0 133.5 192.0 111.0
 N O P R S T U V W Weight
[kg]
 41.5 1.5 16.0 5.0 9.7 8.0 9 9.5 PG 7 0.20
 46.0 4.5 25.5 7.0 12.7 6.5 13 12.0 PG 11 0.40
 51.0 4.2 25.5 10.0 15.6 8.5 18 14.0 PG 11 0.60
 57.5 4.0 30.0 13.0 18.6 18.5 18 22.5 PG 16 1.00
 70.0 11.0 54.0 17.0 24.5 8.5 21 19.5 PG 16 1.70
 76.5 19.1 57.0 22.0 30.5 8.0 36 31.5 PG 29 3.60
 100.0 20.8 79.5 28.5 37.4 11.0 34 46.0 PG 29 5.50
 115.0 23.8 95.0 35.0 43.4 15.0 37 39.0 PG 29 7.50
 140.0 25.5 89.0 47.5 57.5 16.0 37 58.0 PG 29 8.20
195
E .4/12.10


 A B D E F G H J K L M N
 63 58 11 6.6 16 24 9.0 41.5 46.0 28.5 41.5
 79 72 11 6.6 20 29 35.0 63.5 67.0 33.5 46.0
 84 77 11 6.6 25 29 3.5 70.0 74.0 38.0 51.0
 106 96 11 6.6 32 38 38.0 80.0 84.5 44.5 57.5
 128 118 14 9.0 45 38 38.0 76.0 104.0 109.5 54.0 70.0
 170 153 14 9.0 50 49 47.5 95.0 127.0 133.0 60.0 76.5
 175 158 18 11.5 55 49 60.0 120.5 165.0 172.0 76.0 100.0
 195 178 20 14.0 75 49 71.5 143.0 186.0 196.0 92.0 115.0
 220 203 20 14.0 100 49 67.0 133.5 192.0 201.0 111.0 140.0
 O P R S T U V W SW1 SW2 X Weight
[kg]
 1.6 16.0 5.0 9.7 6.4 9 13.5 PG 7 0.26
 4.8 25.5 7.0 12.7 14.2 13 31.0 PG 11 0.50
 4.0 25.5 10.0 15.6 18.0 18 29.5 PG 11 6 13 81 0.80
 4.0 30.0 13.0 18.6 21.0 25 36.5 PG 16 6 17 100 1.10
 11.0 54.0 17.0 24.5 14.0 36 49.0 PG 16 8 19 127 2.50
 19.0 57.0 22.0 30.5 16.0 41 49.0 PG 29 3.90
 20.6 79.5 28.5 37.4 15.0 44 77.0 PG 29 6.70
 23.8 95.0 35.0 43.4 15.0 62 85.0 PG 29 11.00
 25.5 89.0 47.5 57.5 16.0 87 64.0 PG 29 17.50
closed
View X
control knob with
hex. is standard
for size 20 and
above
required surface nish on
interface area
open

Justus-von-Liebig-Str.

Tel: 0 68 97 /509-01
Fax: 0 68 97 /509-598
E-Mail: utec@hydac.com

The information in this brochure relates to
the operating conditions and applications
described.
For applications or operating conditions
not described, please contact the relevant
technical department.
Subject to technical modications.
SW19 metric
SW1 metric
SW2 metric