FEATURES
- Hole pattern to DIN 24340, ISO 4401, nominal size 10
- Check valve sandwich plate type with
check function in one direction, free backflow in the
opposite direction
- easy to assemble under body mounted spool valves to DIN 24340,
to ISO 4401 (use longer screws)
- type to ISO ISO 7790
types.
- type A: Check valve in line A
- type B: Check valve in line B
- type P: Check valve in line P
- type T: Check valve in line T
SPECIFICATIONS
Nominal pressure: max
. 350 bar
Cracking pressure: 0,4 bar
Nominal flow: max. 100 l/min
Fluids: Hydraulic fluid to DIN 51524 part 1 and 2
Media operating temp. range: -20°C up to max. +70°C
Ambient temperature range: -20°C up to max. +50°C
Viscosity range: 15 – 380 mm²/s is recommended
Filtration: Class 20/18/15 to ISO 4406
or cleaner
ISO 4410 Class 20/18/15 to ISO 4406
Weight: 2,77 kg
PERFORMANCE
measured at t = 50°C, ν = 32mm²/s
Function
A1
A2
1 - Housing
2 - RV insert
3 - Spring
up to 350 bar
up to 100 l/min
Pressure drop (bar)
( Index 1 = valve side / Index 2= sub plate side)
Pressure drop p-Q
Check valve
sandwich plate type
ZW-RV10
E 5.199.1 /08.10
SYMBOL
ZW-RV10 A ZW-RV10 B
ZW-RV10 P ZW-RV10 T
A1
B1P1
B2A2
P2
T1A
T2A
T1
B
T2B
814
MODEL CODE
ZW-RV10 – 01 - A 0,4 - V
Name and nominal size
check valve
Sandwich plate type NW6
Series
01 = Standard, phosphated
Type
A = check valve in line A
B = check valve in line B
P = check valve in line P
T = check valve in line T
Cracking pressure
0,4 = 0,4 bar
Seal material
V = Viton (Standard)
N = NBR
Dimensions
Standard models Part No.
ZW-RV10-01-A-0,4-V 6078903
ZW-RV10-01-B-0,4-V 6078904
ZW-RV10-01-P-0,4-V 6078905
ZW-RV10-01-T-0,4-V 6078906
other types on request
4. Bore holes for fixing screws M6
5. O-Ring 12,42 x 1,78 Viton
6. Type plate
7. O-Ring plate
All dimensions in mm.
Fastening elements are not in the scope
of supply.
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
D - 66280 Sulzbach / Saar
Tel. 06897 / 509 -01
Fax 06897 / 509 -598
Email flutec@hydac.com
Annotation
The information in this brochure
relates to the operating conditions
and applications described.
For applications or operating
conditions not described, please
contact the relevant technical
department.
Subject to technical modifications.
Mounting plate to ISO 4401-05-04-0-94
Optional
T port
815