FEATURES
- Hole pattern to ISO 6264-06, Nominal size 10
-pilot operated pressure relief valve with Proportional coil
- electronic control by PEK-SRA s. brochure 5.249.4.0
SPECIFICATIONS
Operating pressure: max. 350 bar
Flow rate: max. 200 l/min
Hysteresis < 5 %
Repeatability: < +/- 1,5 %
Operating fluid: hydraulic oil to DIN 51524 part 1 and 2
Operating fluid temp. range: -20°C up to max. +80°C
Ambient temperature range: -20°C up to max. +50°C
Viscosity range: 7,4 – 400 mm²/s is recommended
Filtration: Class 20/18/15 according to
ISO 4406 class 18/16/13
Switching time: On: 120 ms Off: 90 ms
Type of voltage: DC voltage
Nominal current: 0,86 A at 24VDC (12 V on request)
Resistance at 20°C: 17,6 Ohm at 24V (12V on request)
Coil duty rating: 100% (Continuous)
Electro magnetic
suitability: (EMC) Emissions to EN 50081-1
suitability to EN 50082-2
to Norm 89/336 CEE
IP rating: IP65 (if plug is mounted correctly)
Installation: see installation hints below
Note: Bleed system and valve before
setting in motion
Hole pattern: according to ISO 6264-06
Weight: 5,0 kg
Installation:
We recommend to install the PRE horizontally or vertically with coil at the lower end.
If installed vertically upwards please consider changes of minimal regulated
pressure! Pay attention that no air is in the system. In some applications the coil-
support has to be bleed by the screw at the support. Line T has to be connected
directly to tank. Every counter-pressure on line T has to be added to the regulated
pressure. Maximal permitted counter-pressure at T: 2 bar.
The fixation of the valve will be done by screws or tension rods on a plane surface
which surface finish is equal or higher than the valves finish. If the surface finish is
not as specified above, leakages may occur.
SYMBOL
up to 350 bar
up to 200 l/min
FUNCTION
Proportional pressure
relief valve
pilot operated
subplate
VP-PDBP10
E 5.249.6.0 /08.10