FEATURES
- Hole pattern to ISO 24340, Nominal size 6
- Pilot operated pressure reducing valve
- Full backflow in the opposite direction by built-in
check valve (cracking pressure 0,5 bar)
SPECIFICATIONS
Operating pressure: max. 350 bar
Flow rate: max. 60 l/min
Leakage (internal): < 0,5 l/min
Fluids: Hydraulic oil to DIN 51524 part 1 and 2
Temp. range of the operating fluid: -20°C up to max. +80°C
Ambient temperature range: -20°C up to max. +50°C
Viscosity range: 7,4 – 400 mm²/s is recommended
Filtration: Class 21/19/16 according to ISO4406
Installation: no orientation restrictions
Hole pattern: ISO 24340 Form A6
Weight: 1,2 kg
PERFORMANCE
SYM
BOL
up to 350 bar
up to 60 l/min
Pressure Drop ∆p /Q
Pressure reducing valve
pilot operated
Subplate to ISO 24340
VP-DRP6
E 5.249.15 /08.10
Flow rate
pressure drop
measured at: 33mm²/s, T oil = 46°C
0 10 20 30 40 50 60
l/min
0
5
10
15
20
25
30
35
40
45
50
bar
P -> A
A -> P
Flow rate
Regulating pressure
measured at: 33mm²/s, T oil = 46°C;
090
-60 -40 -20 0 20 40 60
l/min
0
50
100
150
200
250
300
350
400
450
bar
Pressure Range
500
330
780
MODEL CODE
VP-DRP6 090 VR S01/V
Name and size
Pressure reducing valve pilot operated NW 6
Pressure ranges
090 = up to 60 bar
330 = up to 230 bar
500 = up to 350 bar
Adjustment
V = adjustable by tool
Check valve
R (cracking pressure 0,5 bar)
Type
S01 = Standard
Seals
V = Viton (Standard)
N = NBR
DIMENSIONS
Mou
nting plate to ISO 24340 Form A6
1) Mounting plate with O-rings: 4x O-Ring 9,25 x 1,78 Viton
2) Pressure reducing valve adjustable by tool
3) Check valve
Fastening screws: 4x Allen key M5 x 50, Torque: 5 Nm + 0,5 Nm
All dimensions in mm. Fastening elements are not in the scope of delivery.
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
Models on request P
a
r
t No.
VP-DRP6 090VR S01/N 3497267
VP-DRP6 330VR S01/N 3497268
VP-DRP6 500VR S01/N 3497269
781