E 5.231.2.0 /08.10
SYMBOL
E
J
Z
Up to 80 l/min
Up to 350 bar
FEATURES
High flow rate due to optimized casted housing
Small hysteresis by super finish of moving parts
Long life cycle times by armature switching under oil
Minimal wear by hardened and ground valve piston
Simple exchangeability by international standardized hole pattern to ISO 4401
Integrated digital amplifier
SPECIFICATIONS
Operating pressure: ports P,A,B max. 350 bar
port T max. 210 bar
Nominal flow: max. 4 l/min 12 l/min 30 l/min
Hysteresis: (in % of Qmax): < 0,2 %
Repeat accuracy: (in % of Qmax) < +/- 0,2 %
Media operating temp.range: -20°C up to +80°C
Ambient temperature range: -20°C up to +50°C
Hydraulic fluid: Hydraulic fluid to DIN 51524 part 1 / 2
Viscosity range: 10 mm
2
/s up to 400mm
2
/s
Fil
tration: Class 18/16/13 up to 19/17/14 according
to ISO4406
Coil duty rating: 100% continuous
Supply voltage: DC
Nominal current: 0,86 A bei 24VDC
Resistance at 20°C: 17,6 Ohm bei 24VDC
Electromagnetic
compatibility: (EMC) Emissions to EN 50081-1
compatibility to EN 50082-2
to Norm 89/336 CEE
IP rating: IP65
Installation: no orientation restrictions
Hint: Vent system and valve before
setting in motion
Hole pattern: ISO4401-03-02-0-05
Weight: 2,7 kg
4/3-Proportional solenoid valve,
dir
ect acting, with integrated
Electronics and integrated
transducer, subplate to ISO4401
P4WRE 6
FUNCTION
The P4WRE6 is a direct acting
sol
enoid valve which combines the
directional control with the velocity
control of the consumer.
The controlled nominal flow is
proportional to the electrical input signal
at the coil.
Analogue to his size the coil creates a
force and moves the piston against the
spring. Herewith the corresponding
cross section diameters are opened
which determines the flow rate in
dependence of the pressure differential.
The integrated digital electronics permits
a better performance of the valve and
function by
- shortened response times
- reduced hysteresis
- better repeat accuracy
758
p P-T (bar)
p P-T (bar)
Z
Z
Z
Curve taken at 50% flow
and
(P 10 bar P->T)
p P-T (bar)
p P-T (bar)
p P-T (bar)
PERFORMANCE
measured at T oil = 46°C and 33 m/s (The related p is
measured between lines P and T of the valve)
E, J spool
E, J spool
Z spool
Z spool
Z spool
Pressure gain
Response time
Command signal %
Command signal %
Command signal %Command signal %
Command signal %
Command signal %
759
NOTE 1: preview on the Pin A (24 VDC) an external fuse for protecting electronics. Fuse characteristics: 5A/50V type fast.
NOTE 2: preview 24V DC on the PIN C to activate the card power stage.
NOTE 3: The input signal is differential type on E0 version only. For double solenoid valves, with positive reference signal
connected to pin D, the valve opening is P - A and B - T. With zero reference signal the valve is in central position. For “SA”
single solenoid valves, with positive reference to pin D, the valve opening is P-B and A-T. The spool stroke is proportional to
UD - UE. If only one input signal (single-end) is available, the pin B (0V power supply) and the pin E (0V reference signal)
must be connected through a jumper and both connected to GND, electric panel side.
NOTE 4: This value changes, as shown in the table below. When MONITOR function is enabled and the card is enabled, read
the test point pin F in relation to pin B (0V). When detect a failure or error of the sensor LVDT, the drive bring the valve back
in central position and locks it. In this condition the pin F, referring to the pin B, indicates 0V DC output. To reset the fault, the
card must be disabled and re-enable. When the card is disabled, the pin F referred to the pin B shows 2.7V DC output: this
value is given by the voltage of the LIN bus communication and not by the MONITOR value.
Input signal E0 vol
tage signal
Input signal E1 current signal
760
Position encoder – Electrical connection
Pin 1 supply 18 ÷ 36 V Pin 8c
Pin 2 Output ÷ 10 V Pin 24a
Pin 3 0 V Pin 22c
Pin 4 NC NC
ELECTRONICS
Power input: 70
W
Current draw: 2,6 A max.
Nominal voltage: 24 VDC (19-35VDC, ripple max.3Vpp)
Coil duty rating: 100% continuous
Input signal E0: voltage signal +/-10VDC (Impedance Ri >50 kOhm)
Input signal E1: current signal 4-20mA (Impedance Ri =500 Ohm)
Alert signals: Overload and overheating of Electronics, LVDT sensor
failure, cable break, power failure <4mA
Communication: LIN Bus Interface (optional on request)
Electronics port: 7-pin MIL-C-5015-G (DIN43563)
EMC EN61000-6-4: Corresponding 2004/108 CE Standard
EMC EN61000-6-4: Corresponding 2004/108 CE Standard
IP rating: IP65 (CEI EN 60529 Standard)
761
DIMENSIONS
Standard models Part No.
P4WRE 6 E04 D01-24PG E0/V 3565231
P4WRE 6 E12 D01-24PG E0/V 3565232
P4WRE 6 E30 D01-24PG E0/V 3565233
P4WRE 6 J04 D01-24PG E0/V 3565245
P4WRE 6 J12 D01-24PG E0/V 3565246
P4WRE 6 J30 D01-24PG E0/V 3565247
Other types on request
Name
Pro
portional solenoid valve
subplate with integr. Electronics
Nominal size
6
Symbol
E, J, Z
Nominal flow
4 = 4 l/min
12 = 12 l/min (At p=10 bar P-T)
30 = 30 l/min
Type
D01 = Standard type with manual override
Nominal voltage
12= 12 V DC
Coil connector
PG= DIN plug to EN175301-803
Input signal
E0= +/-10 V
E1= 4-20 mA
Seal material
V= FPM (Standard)
N= NBR (optional)
MODEL CODE
P4WRE 6 E 12 D01- 24PG E0 /V
Hole pattern
1) Mounting plate with O-rings 4x 9.25 x 1.78 NBR 90 Shore
2)
F
ree space for mounting the coil
4) Main plug
2) Plug 7 pin DIN 43563 – IP65 PG11 EX7/L/10
(included in delivery Mat. 6080324)
Fastening screws: 4x M5 x 30 (12.9) torque 5 Nm +o,5 Nm
All dimensions in mm. Fastening elements are not in the scope of delivery.
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
762