FEATURES
- Electro-hydraulically operated by pilot valve NW6
- Flows up to 300l/min
- Internal or external pilot supply and drain line selectable
by internal plug setting
SPECIFICATIONS
Nominal pressure: max. 320 bar
Flow-rate: max. 300 l/min (P nach A, B, T)
Control pressure: min. 12 up to max. 280 bar
Pressure in line T: max. 140 bar
(with internal drain)
Pressure in line T: max. 250 bar
(with external drain)
Fluids: Hydraulic oil to DIN 51524 part 1 and 2
Media operating temp. range: -20°C up to max. +80°C
Ambient temperature range: -20°C up to max. +50°C
Viscosity range: 10 – 400 mm²/s is recommended
Filtration: ISO 4406 class 20/18/15
or better
Weight: 8,6 kg incl. pilot valve
Electrics
Type of voltage: DC
Vol
tage tolerance: ±10%
Nominal power: 30W (12V / 2,5A) resp. 32W (24V /1,33A)
Switch-on time: Main stage: 45 ms up to 75 ms
Switch-off time: Main stage: 30 ms up to 60 ms
(Control pressure 100bar)
Coil duty rating: 100%
Electrical connection: plug according to DIN 43650
IP rating: IP 65 nach EN 60529; DIN 40050
with correctly fitted connector
4/3-Directional control valve
electro-hydraulically operated
4WEH I 16 / 4WEH EI 16
B A
SYMBOL
E
H
J
G
EA
D
D/
OF
bis 320 bar
bis 300 l/min
FUNKTION
E 5.227.1.0 /08.10