FEATURES
- Electro-hydraulically operated by pilot valve NW6
- Flows up to 150l/min
- Internal or external pilot supply and drain line selectable
by internal plug setting
SPECIFICATIONS
Nominal pressure: max. 320 bar
Flow-rate:
Symbols E, H, J, EA, max. 150 l/min at 210 bar
Q, D, D-OF (120 l/min at 320 bar)
Symbol G: max. 120 l/min at 210 bar
(100 l/min at 320 bar)
Control pressure: min. 5 up to max. 210 bar
Pressure in line T: max. 140 bar
(with internal drain)
Pressure in line T: max. 210 bar
(with external drain)
Fluids: Hydraulic oil to DIN 51524 part 1 and 2
Media operating temp. range: -20°C up to max. +80°C
Ambient temperature range: -20°C up to max. +50°C
Viscosity range: 10 – 400 mm²/s is recommended
Filtration: ISO 4406 class 20/18/15
or better
Weight: 8,5 kg incl. pilot valve
Electrics
Type of voltage: DC
Vol
tage tolerance: ±10%
Nominal power: 30W (12V / 2,5A) resp. 32W (24V /1,33A)
Switch-on time: Main stage: 50 ms up to 60 ms
Switch-off time: Main stage: 40 ms up to 50 ms
(Control pressure 100bar)
Coil duty rating: 100%
Electrical connection: plug according to DIN 43650
IP rating: IP 65 nach EN 60529; DIN 40050
with correctly fitted connector
E 5.249.13.0 /08.10
4/3-Directional control valve
electro-hydraulically operated
4WEH I 10 / 4WEH EI 10
SYMBOL
E
H
J
G
EA
D
D/OF
Up to 320 bar
Up tp 150 l/min
FUNCTION
B A
706
PERFORMANCE
(plug M5x6)
Symbol Piston position Ports
P -> A P -> B A -> T B -> T P -> T
E not operated
operated 1 1 2 3
H not operated *6
operated 5 5 2 4
J not operated 1
1
operated 1 1 1 4
G not operated 6
operated 6 6 3 5
Q not operated
operated 1 1 2 2
EA not operated
operated - 1 2 -
HA not operated *6
operated - 5 2 -
JA not operated 1
1
operated - 1 1 -
GA not operated 6
operated 6 - - 5
QA not operated
operated - 1 2 -
D not operated 1 - - 3
operated - 1 4 -
D/OF operated 1 1 4 3
* A-B blocked
B blocked
A blocked
Cross section for plug setting
Valve type Plug setting
X Y
Internal pilot supply and no plug plug
external drain
I Internal pilot supply and no plug no plug
drain
external pilot supply and plug plug
drain
EI external pilot supply and plug no plug
internal drain
4/2 directional valve
with spring offset Type 4WEH 10, 16
4/3 directional valve
spring centered Type 4WEH 10, 16
4/2 directional valve
with spring offset Type 4WEH 10, 16
Main
stage
Pilot D
(rotated
assembly)
Main
Valve
plus pilot
P T
a
A B
TP
x
a
y
b
P T
b
A
B
X = extern
Y = extern
X = extern
Y = extern
X = extern
Y = extern
P T
a
A B
TP
x
a
y
b
P T
b
0
A
B
P T
a
A B
TP
x
a
y
b
P T
b
0
A
B
A B
TPX
Y
a
b
A B
TPX Y
a
b
0
A B
TPX
Y
a
b
0
Main
stage
Pilot J
(rotated
assembly)
Main
Valve
plus pilot
Main
stage
Pilot JA
(rotated
assembly)
Main
Valve
plus pilot
707
MODEL CODE
4WEH I 10 E S01 –24DG / V
Name
4/2- resp. 4/3-directional spool valve
with pilot spool valve
Pilot supply and drain
I = internal pilot supply and drain
EI = External pilot supply and internal drain
Nominal size
10 = NW 10
Symbol
Available Symbols: E, J, G, H, Q, D, EA, D-OF
Types
S01 = Standard
So2 = Hole pattern 4401 (on request)
Nominal voltage and plug
12 = 12 Volt DC
24 = 24 Volt DC
DG: DIN plug according to EN 175301-803
DO: M12x1 plug
Seals
V = Viton (Standard)
N = NBR
Models on request Part no.
4WEH I 10 E S01-24DG/N 3492218
4WEH I 10 J S01-24DG/N 3492221
4WEH I 10 G S01-24DG/N 3492224
4WEH I 10 H S01-24DG/N 3492223
4WEH I 10 D S01-24DG/N 3492236
4WEH I 10 EA S01-24DG/N 3492237
4WEH I 10 D/OF S01-24DG/N 3492238
Electro-hydraulic pilot control
FUNCTI
ON
HYDAC 4/2 und 4/3 directional valves for oil hydraulic
systems are to open and close flow paths. In de-energized
mode the main piston will be retained by a spring in the initial
position. An under oil switching magnet pushes the pilot piston
in its end position whereby the main piston – hydraulically
operated – moves to his end position.
Hereby the chosen flow paths will be enabled according to the
symbol of the valve. After switching-off the solenoid the pilot
piston will be pushed back in its initial position by the spring. A
manual override allow the switching of the pilot valve without
erection of the solenoid.
708
Hole pattern according to ISO 4401-05
CETOP 4.2-4 P05-320
DIMENSIONS
1) Manual override
2) Space for mounting the coil
3) Space for mounting the plugs
4) DIN plug (optional)
5) Fixing plate with O-rings
5x O-Ring 12,42 x 1,78 – 90 Sh
2x O-Ring 9,25 x 1,78 – 90 Sh
Fixing screws: 4x M6 x 35 DIN 912-12.9
Torque 14 +1 Nm
All dimensions in mm.
Fixing elements are not in the scope of
supply .
HYDAC Fluidtechnik GmbH
Just
us-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
709