4/2- directional spool valve
solenoid actuated, direct acting
4 WE 6 D
SYMBOL
up
to 80 l/min
up to 320 bar
FEATURES:
- Direct operated, solenoid actuated valve NG 6
- Economical and reliable due to simple design
- Oil- immersed solenoid armature for long life and low noise operation
- Solenoid coils can be replaced with no possibility of oil leakage
- Interface to DIN 24340 Form A6, ISO 4401
- Manual override
SPECIFICATIONS:
Operating pressure: port A,B,P: pmax= 320 bar
port T: pmax= 210 bar
Flow rate: max. 80 l/min
Media operating temp. range: min. –20°C up to max. +80°C
Ambient temperature range: min. –20°C up to max. +55°C
Fluids: hydraulic oil to DIN 51524 part1 and 2
Viscosity range: 10 mm²/s up to 500 m/s is recommended
Filtration: Class 20/18/15 according to
ISO 4406 or cleaner
Max. switching frequency: 15.000/h
Installation: no orientation restrictions
Manual override: up to approx. 50 bar tank pressure possible
Seal materials: Standard Viton
Weight: 1,5 kg
Electrics
Type of voltage: DC voltage
Voltage tolerance: ±10%
Nominal power: 30W (12V / 2,5A) resp. 32W (24V / 1,33A)
Switch-on time: Switch-on time (coil): 20 ms up to 70 ms
Switch-off time (spring): 10 ms up to 60 ms
Coil duty rating: 100%
Electrical connection: plug to DIN 43650
IP rating: IP 65 to EN 60529; DIN 40050 provided
the connector is fitted correctly
FUNCTION:
HYDAC 4/2 directional spool valves
in the series 4WE 6 D are directional
valves for oil- hydraulic systems,
which serve to open and close flow
paths. In the de- energised mode the
control spool is held in the rest
position by the return spring. The
actuation of the control spool occurs
via an oil- immersed solenoid. The
solenoid pushes the control spool
from its rest position to its final
position. This opens the required flow
paths according to the symbol. When
the solenoid is de- energised, the
control spool is pushed back to the
rest position by the return spring. A
manual override permits the valve to
be switched without energising the
solenoid.
TP
A B
E 5.213.0 /08.10
636
0
50
100
150
200
250
300
350
0 10 20 30 40 50 60 70 80
Q [l/min]
p [bar]
Hole pattern
to DIN 24340- A6
The operating limit was determined with warm coil and an undervoltage
of
10%. The specified operating limit is only valid for use with two flow
directions (e.g. flow from P to A and simultaneous flow from B to T).
Here see specific valve symbol. Using only one flow direction may
reduce the operating limit.
By operation with G96/G205 coil the max. flow rate has to be reduced
by 10%. The Switch-on time will increase.
Fastening screws: M5 x 30 DIN 912-10.9
Tor
que: 6 + 1 Nm
Plug and fastening screws (4 pcs.) must be ordered
separately.
Crossover
4WE 6 D S01 - 12DG / V
Nam
e
4/2-directional-spool valve
Nominal size
6 = Nominal size 6
Symbol
Series
Determined by manufacturer
Nominal voltage
12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
96 and 205 Volt DC voltage on demand (only type DG)
DG: DIN plug to EN 175301-803
DO: M12x1 plug
Seal material
V = Viton (Standard)
N = NBR
DIMENSIONS
M12 coil
Electric
wiring
Standard models
Name P
art No.
4WE 6 D S01-12DG /V 6063112
4WE 6 D S01-24DG /V 6063118
other types on demand
Supply voltage Nominal voltage Nominal power
+/- 10% of the DC-coil of the DC-coil
110 V – 50/60 Hz 96 V 32 W
230 V – 50/60 Hz 205 V 33 W
by using a plug socket with integrated rectifier
0
5
10
15
20
0 10 20 30 40 50 60 70 80
Q [l/min]
dp [bar]
P-A A-T
P-B B-T
P-A A-T
P-B B-T
in initial position
Pressure drop
measured at ν = 36 mm²/s and t = 45°C
Operating limits
measured at ν = 36 mm²/s and t = 45°C
Model Code
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
637