4/2- directional- spool valve
solenoid actuated, direct acting
4 WE 6 D-OF
SPECIFICATIONS:
Operating pressure: por
t A,B,P: pmax= 320 bar
port T: pmax= 210 bar
Flow rate: max. 80 l/min
Media operating temp. range: min. –20°C up to max. +8C
Ambient temperature range: min. –20°C up to max. +5C
Fluids: hydraulic oil to DIN 51524 part1 and 2
Viscosity range: 10 mm²/s up to 500 mm²/s is recommended
Filtration: Class 20/18/15 according to
ISO 4406 or cleaner
class20/18/15
Max. switching frequency: 15.000/h
Installation: no orientation restrictions
Manual override: up to approx. 50 bar tank pressure possible
Seal materials: Standard Viton
Weight: 2,0 kg
Electrics
Type of voltage: DC voltage
Voltage tolerance: ±10%
Nominal power: 30W (12V / 2,5A) resp. 32W (24V / 1,33A)
Switch-on time: Switch-on time (coil): 20 ms up to 70 ms
Switch-off time (spring): 10 ms up to 60 ms
Coil duty rating: 100%
Electrical connection: plug to DIN 43650
IP rating: IP 65 to EN 60529; DIN 40050 provided
the connector is fitted correctly
SYMBOL
up to 80 l/min
up to 320 bar
TP
A B
FEATURES:
- Direct operated, solenoid actuated valve NG 6
- Economical and reliable due to simple design
- Oil- immersed solenoid armature for long life and low noise operation
- Solenoid coils can be replaced with no possibility of oil leakage
- Interface to DIN 24340 Form A6, ISO 4401
- Manual override
FUNCTION:
HYDAC 4/2 directional spool
valves in the series 4WE 6 D-OF
are directional valves for oil-
hydraulic systems, which serve to
open and close flow paths. The
4WE 6 D-OF is a directional valve
with two spool positions, two
solenoids and one detent. It
alternately locks the two spools in
position. Therefore the solenoid
needs not to be permanently
energized.
E 5.216.0 /08.10
638
0
50
100
150
200
250
300
350
0 10 20 30 40 50 60 70 80
Q [l/min]
p [bar]
0
5
10
15
20
0 10 20 30 40 50 60 70 80
Q [l/min]
dp [bar]
P-A A-T
P-B B-T
P-A A-T
P-B B-T
in initial position
4WE 6 D -OF S01 - 12DG /V
Nam
e
4/2-directional-spool valve
Nominal size
6 = Nominal size 6
Symbol
(-OF = Special type with detent)
Series
Determined by manufacturer
Nominal voltage
12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
96 and 205 Volt DC voltage on demand (only type DG)
DG: DIN plug to EN 175301-803 DO: M12x1 plug
Seal material
V = Viton (Standard)
N = NBR
Standard models
Type Part No.
4WE 6 D-OF S01–24DG /V with detent 6070560
Other types on request
The operating limit was determined with warm coil and an undervoltage
of 10%. The specified operating limit is only valid for use with two flow
directions (e.g. flow from P to A and simultaneous flow from B to T).
Here see specific valve symbol. Using only one flow direction may
reduce the operating limit.
By operation with G96/G205 coil the max. flow rate has to be reduced
by 10%. The Switch-on time will increase.
Supply voltage Nominal voltage Nominal power
+/- 10% of the DC-coil of the DC-coil
110 V – 50/60 Hz 96 V 32 W
230 V – 50/60 Hz 205 V 33 W
by using a plug socket with integrated rectifier
Pressure drop
measured at ν = 3
6 mm²/s and t = 45°C
Operating limits
measured at ν = 36 mm²/s and t = 45°C
Model Code
Hole pattern
to DIN 24340- A6
Fastening screws: M5 x 30 DIN 912-10.9
Tor
que: 6 + 1 Nm
Plug and fastening screws (4 pcs.) must be ordered
separately.
Crossover
HYDAC Fluidtechnik GmbH
Just
us-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com