TP
A B
4/2- directional- spool valve
solenoid actuated, direct acting
4 WE 10 EA
SPECIFICATIONS:
Operating pressure: por
t A,B,P: pmax= 320 bar
port T: pmax= 210 bar
Flow rate: max. 120 l/min
Media operating temp. range: min. –20°C up to max. +8C
Ambient temperature range: min. –20°C up to max. +5C
Fluids: hydraulic oil to DIN 51524 part1 and 2
Viscosity range: 10 mm²/s up to 500 mm²/s is recommended
Filtration: Class 20/18/15 according to
ISO 4406 or cleaner
Max. switching frequency: 15.000/h
Installation: no orientation restrictions
Manual override: up to approx. 50 bar tank pressure possible
Seal materials: Standard Viton
Weight: 4,3 kg
Electrics
Type of voltage: DC voltage
Voltage tolerance: ±10%
Nominal power: 42W (12V / 2,9A) or 48W (24V / 2,0A)
Switch-on time: Switch-on time (coil): 80ms up to 120ms
Switch-off time (spring): 70ms up to110ms
Switch-on time (coil with rectifier):
90 ms up to 130 ms
Switch-off time (spring):160ms up to 200ms
Coil duty rating: 100%
Electrical connection: plug to DIN 43650
IP rating: IP 65 to EN 60529; DIN 40050 provided
the connector is fitted correctly
SYMBOL
up to 120 l/min
up to 320 bar
FEATURES:
- Direct operated, solenoid actuated valve NG 6
- Economical and reliable due to simple design
- Oil- immersed solenoid armature for long life and low noise operation
- Solenoid coils can be replaced with no possibility of oil leakage
- Interface to DIN 24340 Form A6, ISO 4401
- Manual override
FUNCTION:
HYDAC 4/2 directional spool valves
in the series 4WE 10 EA are
directional valves for oil- hydraulic
systems, which serve to open and
close flow paths. In the de-
energised mode the control spool is
held in the rest position by the return
spring. The actuation of the control
spool occurs via an oil- immersed
solenoid. The solenoid pushes the
control spool from is rest position to
is final position. This opens the
required flow paths according to the
symbol. When the solenoid is de-
energised, the control spool is
pushed back to the rest position by
the return spring. A manual override
permits the valve to be switched
without energising the solenoid.
E 5.221.0 /08.10
668
0
5
10
15
20
0 20 40 60 80 100 120
Q [l/min]
dp [bar]
0
50
100
150
200
250
300
350
0 20 40 60 80 100 120
Q [l/min]
p [bar]
A - T
P - B
4WE 10 EA S01 - 12DG / V
Name
4/2-directional-spool valve
Nominal size
10 = Nominal size 10
Symbol
Series
Determined by manufacturer
Nominal voltage
12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
96 and 205 Volt DC voltage on demand (only type DG)
DG: DIN plug to EN 175301-803
Seal material
V = Viton (Standard)
N = NBR
Standard models
Type Part No.
4WE 10 EA S01–12DG /V 6063150
4WE 10 EA S01–24DG /V 6063156
Other types on request
The operating limit was determined with warm coil and an undervoltage
of
10%. The specified operating limit is only valid for use with two flow
directions (e.g. flow from P to A and simultaneous flow from B to T).
Here see specific valve symbol. Using only one flow direction may
reduce the operating limit.
By operation with G96/G205 coil the max. flow rate has to be reduced
by 10%. The Switch-on time will increase.
Supply voltage Nominal voltage Nominal power
+/- 10% of the DC-coil of the DC-coil
110 V – 50/60 Hz 96 V 32 W
230 V – 50/60 Hz 205 V 33 W
by using a plug socket with integrated rectifier
Pressure drop
measured at ν = 3
6 mm²/s and t = 45°C
Operating limits
measured at ν = 36 mm²/s and t = 4C
Model Code
Hole pattern
to DIN 24340- A10
Fastening screws: M6 x 40 DIN 912-10.9
Tor
que: 10 + 1 Nm
Plug and fastening screws (4 pcs.) must be ordered
separately.
Crossover
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
DIMENSIONS
M12 coil
Electric
wiring
669