9
E 2.907.1.0/02.14
2
2.1 MEDIUM HEAVY DUTY SERIES
CONTENTS PPV100S
Ordering Code 2.1.1 Medium Heavy Duty Series
Technical Information 2.1.2 Specifications
2.1.3 Max. drive and through drive torque
2.1.4 Pump combinations for PPV100S
2.1.5 Specifications for special fluids
2.1.6 Seals
2.1.7 Filtration
2.1.8 Hydraulic fluids
2.1.9 Temperature range
2.1.10 Viscosity range
2.1.11 Adjustments
2.1.12 Installation notes
Control Options 2.1.13 Standard pressure control
2.1.14 Remote pressure control
2.1.15 Load sensing control
2.1.16 Availability of control type
Performance Data 2.1.17 PPV100-16
2.1.18 PPV100S37
2.1.19 PPV100S56
2.1.20 PPV100S71
2.1.21 PPV100S1 00
2.1.22 PPV100S145
2.1.23 PPV100S180
Dimensions 2.1.24 PPV100-16
2.1.25 PPV100S37 with 2-hole mounting flange
2.1.26 PPV100S37 with 4-hole mounting flange
2.1.27 PPV100S56 with 2-hole mounting flange
2.1.28 PPV100S56 with 4-hole mounting flange
2.1.29 PPV100S71
2.1.30 PPV100S100
2.1.31 PPV100S145
2.1.32 PPV100S180
10
E 2.907.1.0/02.14
PPV100S 16 - F R 01 K K1 E1 C __ – 10 – XXXX
Axial piston pump
Medium Heavy Duty Series
with lateral ports and
prepared for through drive
Size
16 16.3 cm³/rev
37 37.1 cm³/rev
56 56.3 cm³/rev
71 70.7 cm³/rev
100 100.5 cm³/rev
145 145.2 cm³/rev
180 180.7 cm³/rev
Mounting type
F Flange mounting
Shaft rotation
R Clockwise
Control type
01 Pressure compensator
07 Remote pressure compensator
14 Load sensing control
Pressure setting range
K 50 - 350 bar (standard, for control type 01 only)
Shaft Extension
K1 Parallel keyed shaft to ISO
K2 Parallel keyed shaft to SAE
SP Splined shaft to SAE
Flange type
E1 ISO 3019-2, metric thread
U1 SAE version, UN thread
U2 SAE version, BSPF-/ metric thread
J1 SAE version, RC-/. metric thread
Mounting flange
D 4-hole mounting flange (not for size 16)
C 2-hole mounting flange (only for sizes 16/37/56)
Through drive versions
- Single pump with steel case (standard)
A SAE A through drive (sizes 16-180)
AB SAE AB through drive (sizes 16-180)
B SAE B through drive (sizes 37-180)
BB SAE BB through drive (sizes 37-180 only)
C SAE C through drive (sizes 37-180 only)
CC SAE CC through drive (sizes 100-180 only)
D SAE D through drive (sizes 145-180 only)
Design number
10 Standard
Design standard
- Standard (FPM seal)
30 (see specifications for special fluids at point 2.1.5)
450 (see specifications for special fluids at point 2.1.5)
Modification number
XXXX Determined by manufacturer
ORDERING CODE
2.1.1 Medium Heavy Duty Series
11
E 2.907.1.0/02.14
2
TECHNICAL INFORMATION
2.1.2 Specifications
2.1.3 Max. drive and through drive torques
Pump size 16 37
Mounting flange 2-hole 2-hole 4-hole
Maximum torque on
primary shaft [Nm]
ISO shaft, keyed 94 295 451
SAE shaft, keyed 135 295 528
SAE splined shaft 136 364 784
Max. through drive
torque [Nm]
ISO shaft, keyed 76 295 295
SAE shaft, keyed 76 295 295
SAE splined shaft 76 295 295
Pump size 56 71
Mounting flange 2-hole 4-hole 4-hole
Maximum torque on
primary shaft [Nm]
ISO shaft, keyed 295 451 451
SAE shaft, keyed 295 528 528
SAE splined shaft 364 784 784
Max. through drive
torque [Nm]
ISO shaft, keyed 295 295 297
SAE shaft, keyed 295 295 297
SAE splined shaft 295 295 297
Pump size 100 145 180
Mounting flange 4-hole 4-hole 4-hole
Maximum torque on
primary shaft [Nm]
ISO shaft, keyed 789 1295 1295
SAE shaft, keyed 852 1436 1436
SAE splined shaft 1321 1965 1965
Max. through drive
torque [Nm]
ISO shaft, keyed 609 609 609
SAE shaft, keyed 609 609 609
SAE splined shaft 609 609 609
Pump size
16 37 56 71 100 145 180
Geometric displacement
[cm³/
rev]
16.3 37.1 56.3 70.7 100.5 145.2 180.7
Pressure
Rated
[bar]
315
Peak 350
Drive speed
Min.
[rpm]
600
Max. (at -0.2 bar inlet
pressure)
3600 2700 2500 2300 2100 1800 1800
Max. (at 0 bar inlet
pressure)
3800 2700 2700 2400 2200 2000 1800
Power (1500 rpm, 315 bar)
[kW] 14 32 48 60 86 126 156
Pre-fill oil volume
[cm³] 400 700 900 1300 1700 2400 3200
Approx. weight (with pressure
compensator 01)
[kg]
14.5 19.5 25.7 35 44.6 60 70.4
Approx. weight (with remote
pressure compensator 07)
16.2 21.2 27.4 37.2 46.9 62.2 72.6
Approx. weight (with load sensing
control 14)
17.5 22.5 28.7 38 47.6 63 73.4
Moment of inertia
[kgm²] 0.0009 0.0034 0.0069 0.0092 0.0163 0.0277 0.0362
12
E 2.907.1.0/02.14
2.1.6 Seals
The pump series is equipped
with fluorocarbon (FPM) seals as
standard.
If special hydraulic fluids are used,
the seal material must be changed if
required.
2.1.7 Filtration
For maximum service life of the
pump and system components, the
system should be protected from
contamination by effective filtration.
Cleanliness class to NAS 1638
Class 10 (21/19/16 ISO 4406:1999)
or cleaner.
2.1.5 Specifications for special fluids
Fluid type
Pressure
[bar]
Drive speed
[rpm]
Temperature
range
[°C]
Viscosity
range
[cSt]
Design
standard*
2
Rated Intermittent Rated Maximum
Water glycol
Water > 35 %
Polymer solution
(HFC)
210 210 1200 1800*
1
0 - 50
20 - 200
30
Phosphate ester
synthetic (HFD-R)
210 210 1200 1800*
1
0 - 60
Polyolester
synthetic
(HFD-U)
280 320 1200 1800 0 - 60 450
*1 – If a drive speed of 1500 rpm or greater is used, an overhead reservoir is required.
*2 – Use "Design Standard" eld in Ordering Code 2.1.1.
2.1.8 Hydraulic fluids
The pump series is designed for use
with
HL Hydraulic oil
HFC Water glycol
HLP Hydraulic oils of the R&O type
HFD-U Polyolester
HFD-R Phosphate ester
For use with other fluids, please contact
HYDAC DRIVE CENTER.
2.1.10 Viscosity range
Minimum viscosity:
10 cSt (mm²/s)*
Short-term ( t 1 min) for a max.
temperature at drain port of 95 °C
Normal operating viscosity:
10 - 200 cSt (mm²/s)*
Maximum viscosity:
1000 cSt (mm²/s)*
Short-term ( t 1 min) for cold starts
(p 30 bar, n 1000 rpm,
tmin - 10 °C)
*measured at drain port
For low temperature applications,
please contact HYDAC DRIVE
CENTER
2.1.9 Temperature range
-20 to + 95 °C oil temperature
-20 to + 50 °C ambient temperature
Note:
The highest fluid temperature will be at
the drain port of the pump, up to 20 °C
higher than in the reservoir.
2.1.4 Pump combinations PPV100S
Primary stage
Secondary stage
PPV100S16 PPV100S37 PPV100S56 PPV100S71 PPV100S100 PPV100S145 PPV100S180
PPV100S16
PPV100S37
PPV100S56
PPV100S71
PPV100S100
PPV100S145
PPV100S180
PGE102
PGE103
PPV101-45
PPV101-80
PPV101-112/140
PPV101-200
PGI100-2
PGI101
* For other pump combinations, please contact HYDAC DRIVE CENTER.
13
E 2.907.1.0/02.14
2
2.1.11 Adjustments
The pumps are supplied with a minimum discharge pressure and maximum flow
rate setting. Pressure and flow rate can be adjusted using the adjustment screws
to meet your system requirements.
Pump size
Volume Pressure
Volume adjustment
screw rate
Min. adjustable
displacement
Pressure adjustment
screw rate
[cm³ per turn] [cm³/rev] [bar per turn]
PPV100S16 1.4 8
55
PPV100S37 3.3 16
PPV100S56 4.2 35
PPV100S71 4.9 45
63PPV100S100 6.2 63
PPV100S145 9.4 95
PPV100S180 10.3 125 57
PPV100S180
PPV100S145
PPV100S100
PPV100S71
PPV100S56
PPV100S37
PPV100S16
Lock nut
Retainer
Geometric displacement
Adjustment screw extended length "L"
Case
Flow adjustment
screw
14
E 2.907.1.0/02.14
2.1.12 Installation notes
The pump should be installed horizontally with the case
drain line initially rising above the level of the pump before
continuing to the tank as shown in the diagram below. Do
not connect the drain line to the suction line. The top drain
port should always be used and the internal diameter of
the drain line should be equal to or larger than the drain
port to minimise pressure in the pump case. The pressure
in the pump case should not exceed 1 bar as shown in the
diagram below. Peak pressure should never exceed 4 bar.
Precautions:
z The distance between suction and drain pipes must be
200 mm minimum.
z Suction and drain pipes must be immersed at least 200 mm
below the lowest oil level under operating conditions.
z The distance between the oil surface and the centre of the
shaft must not exceed 1 m.
z The oil in the pump case must be refilled if the pump has
not been operated for one month or longer.
z When installing a HYDAC pump always ensure that the
fluid in the pump is prevented from draining away during
stoppages.
Installing the pump above the tank
0.1 sec
1 bar
4 bar
P
Suction line
Drain pipe
200 mm
minimum
depth
200 mm
minimum
depth
Oil
Oil
Oil
Must be higher than
top of pump case
200 mm
minimum
depth
Maximum
1 m
(peak)
(normal)
Installing the pump vertically
For applications requiring vertical installation (shaft at the
top) please connect lines as shown in the diagram below.
The oil level in the tank should be higher than the pump
mounting flange (see diagram
). If the oil level in the tank
is lower than the pump mounting flange then the drain line
should be installed as shown in diagram
.
Once the pump is installed in the tank and immersed in
the oil, the drain ports must be open to provide adequate
lubrication to the internal components.
If the pump is installed outside the tank, there must be a
separate drain line to the tank (diagram
). If the drain
line is higher than the oil level, fill the line with oil before
commissioning.
Drain line
Oil
Oil
Drain port
Min. oil level
15
E 2.907.1.0/02.14
2
CONTROL OPTIONS
2.1.13 Standard pressure control
Description Performance characteristics Hydraulic circuit
z When the system pressure increases
and comes close to the preset cut-off
pressure, the pump flow decreases
automatically and the set pressure is
maintained.
2.1.14 Remote pressure control
Description Performance characteristics Hydraulic circuit
z The pump is used in combination with
the pressure relief valve or multistage
pressure relief valve. By controlling the
pilot pressure, the full cut-off pressure
can be controlled remotely to meet
system requirements.
2.1.15 Load sensing control
Description Performance characteristics Hydraulic circuit
z This is an energy-saving type of control
which maintains the pump flow and
load pressure at the absolute minimum
level necessary to operate the actuator.
z This type of control automatically
regulates the displacement so that the
differential pressure via the throttle
valve remains constant. To do so, the
load pressure must be introduced to
the load sensing port "L" of the pump
through an external line.
z Remote control of the pressure
compensator is provided via the pilot
port "PP".
z The standard differential pressure
setting is 15 bar. The differential
pressure adjustment range is
10 to 30 bar.
*A throttle valve is not included with the pump.
*
Pressure
Pressure
Output flow
Output flow
Pressure
Output flow
PP
Recommended valve for use with remote pressure control
Type: Part no.:
DB3E-02X-350V 397405
16
E 2.907.1.0/02.14
2.1.16 Availability of control type
Pump size
Geometric
displacement
cm3/rev
01
Pressure compensator
type
07
Remote pressure
compensator type
14
Load sensing
type
PPV100S16 16.3
l l l
PPV100S37 37.1
l l l
PPV100S56 56.3
l l l
PPV100S71 70.7
l l l
PPV100S100 100.5
l l l
PPV100S145 145.2
l l l
PPV100S180 180.7
l l l
17
E 2.907.1.0/02.14
2
50
55
60
65
70
75
80
0 50 100 150 200 250 300 350
dB(A)
1500 U/min
1800 U/min
50
55
60
65
70
75
80
0 50 100 150 200 250 300 350
1500 U/min
dB(A)
1800 U/min
PERFORMANCE DATA
2.1.17 PPV100S16
z Performance characteristic curve
z Drive power
z Full cut-off power
z Noise level
z Drain z Drain
Volumetric efficiency
Drive power
Drive power
Drive power
Output flow
Full cut-off
Full flow
Operating pressure Operating pressure
Drive power
Drive power
Drive power
Drive power
Drive power
Drive power
Drive power
Efficiency
Efficiency
Efficiency
Overall efficiency
Overall efficiency
Overall efficiency
Output flow
Output flow
Output flow
Output flow
Output flow Output flow Output flow
Output flow
Output flow
Operating pressure Operating pressure Operating pressure
Volumetric efficiency Volumetric efficiency
Noise level
Noise level
Full cut-off Full flow
Operating pressure
Operating pressure
* measured with noise level meter 1 metre away from pump in an anechoic room using a flexible coupling
to DIN45635
18
E 2.907.1.0/02.14
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300 350
dB(A)
1800 U/min
1500 U/min
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300 350
dB(A)
1800 U/min
1500 U/min
2.1.18 PPV100S37
z Performance characteristic curve
z Drive power
z Full cut-off power
z Noise level
z Drain
Drive power
Drive power
Output flow
Full cut-off
Full flow
Operating pressure
Operating pressure
Drive power
Drive power
Output flow Output flow Output flow
Noise level
Noise level
Full cut-off
Full flow
Operating pressure
Operating pressure
Volumetric efficiency
Drive power
Drive power
Drive power
Drive power
Drive power
Drive power
Efficiency
Efficiency
Efficiency
Overall efficiency
Overall efficiency
Overall efficiency
Output flow
Output flow
Output flow
Output flow
Output flow
Output flow
Operating pressure Operating pressure Operating pressure
Volumetric efficiency Volumetric efficiency
Note: The dotted lines in the graph are below the minimum adjustable flow
* measured with noise level meter 1 metre away from pump in an anechoic room using a flexible coupling
to DIN45635
19
E 2.907.1.0/02.14
2
50
55
60
65
70
75
80
0 50 100 150 200 250 300 350
dB(A)
1500 U/min
1800 U/min
50
55
60
65
70
75
80
0 50 100 150 200 250 300 350
dB(A)
1800 U/min
1500 U/min
2.1.19 PPV100S56
z Performance characteristic curve
z Drive power
z Full cut-off power
z Noise level
z Drain
Volumetric efficiency
Drive power
Drive power
Drive power
Drive power
Drive power
Drive power
Efficiency
Efficiency
Efficiency
Overall efficiency
Overall efficiency
Overall efficiency
Output flow
Output flow
Output flow
Output flow
Output flow
Output flow
Operating pressure Operating pressure Operating pressure
Volumetric efficiency Volumetric efficiency
Drive power
Drive power
Drive power
Output flow Output flow Output flow
Drive power
Output flow
Full cut-off
Full flow
Operating pressure Operating pressure
Noise level
Noise level
Full cut-off Full flow
Operating pressure
Operating pressure
Note: The dotted lines in the graph are below the minimum adjustable flow
* measured with noise level meter 1 metre away from pump in an anechoic room using a flexible coupling
to DIN45635
20
E 2.907.1.0/02.14
55
60
65
70
75
80
0 50 100 150 200 250 300 350
dB(A)
1500 U/min
1800 U/min
55
60
65
70
75
80
0 50 100 150 200 250 300 350
dB(A)
1800 U/min
1500 U/min
2.1.20 PPV100S71
z Performance characteristic curve
z Drive power
z Full cut-off power
z Noise level
z Drain
Volumetric efficiency
Drive power
Drive power
Drive power
Drive power
Drive power
Drive power
Efficiency
Efficiency
Efficiency
Overall efficiency
Overall efficiency Overall efficiency
Output flow
Output flow
Output flow
Output flow
Output flow
Output flow
Operating pressure Operating pressure Operating pressure
Volumetric efficiency Volumetric efficiency
Drive power
Drive power
Drive power
Output flow Output flow Output flow
Drive power
Output flow
Full cut-off
Full flow
Operating pressure
Operating pressure
Noise level
Noise level
Full cut-off Full flow
Operating pressure Operating pressure
Note: The dotted lines in the graph are below the minimum adjustable flow
* measured with noise level meter 1 metre away from pump in an anechoic room using a flexible coupling
to DIN45635
21
E 2.907.1.0/02.14
2
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300 350
dB(A)
1500 U/min
1800 U/min
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300
350
dB(A)
1500 U/min
1800 U/min
2.1.21 PPV100S100
z Performance characteristic curve
z Drive power
z Full cut-off power
z Noise level
z Drain
Volumetric efficiency
Drive power
Drive power
Drive power
Drive power
Drive power
Drive power
Efficiency
Efficiency
Efficiency
Overall efficiency
Overall efficiency
Overall efficiency
Output flow
Output flow
Output flow
Output flow
Output flow
Output flow
Operating pressure Operating pressure Operating pressure
Volumetric efficiency Volumetric efficiency
Drive power
Drive power
Drive power
Output flow Output flow Output flow
Drive power
Output flow
Full cut-off
Full flow
Operating pressure Operating pressure
Noise level
Noise level
Full cut-off
Full flow
Operating pressure Operating pressure
Note: The dotted lines in the graph are below the minimum adjustable flow
* measured with noise level meter 1 metre away from pump in an anechoic room using a flexible coupling
to DIN45635
22
E 2.907.1.0/02.14
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300 350
dB(A)
1500 U/min
1800 U/min
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300
350
dB(A)
1800 U/min
1500 U/min
2.1.22 PPV100S145
z Performance characteristic curve
z Drive power
z Full cut-off power
z Noise level
z Drain
Volumetric efficiency
Drive power
Drive power
Drive power
Drive power
Efficiency
Efficiency
Overall efficiency
Overall efficiency
Output flow
Output flow
Output flow
Output flow
Operating pressure Operating pressure
Volumetric efficiency
Note: The dotted lines in the graph are below the minimum adjustable flow
Drive power
Drive power
Output flow Output flow
Drive power
Output flow
Full cut-off
Full flow
Operating pressure Operating pressure
Noise level
Noise level
Full cut-off Full flow
Operating pressure
Operating pressure
* measured with noise level meter 1 metre away from pump in an anechoic room using a flexible coupling
to DIN45635
23
E 2.907.1.0/02.14
2
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300 350
dB(A)
1500 U/min
1800 U/min
55
60
65
70
75
80
85
90
0 50 100 150 200 250 300 350
dB(A)
1800 U/min
1500 U/min
2.1.23 PPV100S180
z Performance characteristic curve
z Drive power
z Full cut-off power
z Noise level
z Drain
Volumetric efficiency
Drive power
Drive power
Drive power
Drive power
Efficiency
Efficiency
Overall efficiency
Overall efficiency
Output flow
Output flow
Output flow
Output flow
Operating pressure Operating pressure
Volumetric efficiency
Note: The dotted lines in the graph are below the minimum adjustable flow
Drive power
Drive power
Output flow Output flow
Drive power
Output flow
Full cut-off
Full flow
Operating pressure Operating pressure
Noise level
Noise level
Full cut-off
Full flow
Operating pressure Operating pressure
* measured with noise level meter 1 metre away from pump in an anechoic room using a flexible coupling
to DIN45635
24
E 2.907.1.0/02.14
10
166.5
46
212.5
28 "DR"
23.8
166.5
26.2
50.8
76.5
61.5
52.4
45°
45°
105
79
81
109.5
221
81
71"DR"
79.5
74.5
38
19,5
22x6
DIN332-
R3.15×6.7
36
28
Ø18
+0.008
-0.003
20.5
+0.008
-0.133
11
130
95
106
11
130
95
109
28 x 4,76
DIN332-
R3.15×6.7
33
41
Ø19.05
0
-0.03
21.24
0
-0.16
10
36
6.4
Ø80
0
-0.046
10
41
6.4
82,55
DIMENSIONS
2.1.24 PPV100S16
PPV100S16 with pressure control 01
Mounting flange and shaft options
"SP" SAE AB Splined shaft
"U1/U2/J1" SAE A Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Filling port
SW22
Drain port "DR"
(G 1/2)
Discharge port
"P" (Ø 19)
SP splined shaft
11T-16/32DP
(ANSI 8 92.1)
Max.
Dec.
1/4-20 UNC
14 deep
Dec.
Flow adj. screw
SW13
Suction port "S"
(Ø 26)
Pressure adj.
screw
SW13
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S16-FR___E1C-10 M10; 19 deep M10; 19 deep
M22x1.5;
13 deep
M14x1.5 ;
13 deep
M14x1.5 ;
13 deep
3/4" 1"
PPV100S16-FR___U1C-10
3/8-16 UNC;
17 deep
3/8-16 UNC;
17 deep
7/8-14 UNF 1/2-20 UNF 1/2-20 UNF 3/4" 1"
PPV100S16-FR___U2C-10 M10; 19 deep M10; 19 deep
G 1/2;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
3/4" 1"
PPV100S16-FR___J1C-10 M10; 19 deep M10; 19 deep Rc 1/2
Rc 1/4;
24 deep
Rc 1/4;
24 deep
3/4" 1"
25
E 2.907.1.0/02.14
2
129,5
125,5
78,5
31,5 "PP"
61,5 "S"
189,3
125,5
SW 14
131,5
206,8
89,5
31,5 "PP"
75,5 "L"
146
SW 14
138.5
PPV100S16 with remote pressure control 07
PPV100S16 with load sensing control 14
Remote control port "PP"
Pressure
adj. screw
Load sensing port "L"
Load sensing
diff. pressure
adj. screw
Pressure
adj. screw
Remote control port "PP"
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S16-FR___E1C-10 M10; 19 deep M10; 19 deep
M22x1.5;
13 deep
M14x1.5 ;
13 deep
M14x1.5 ;
13 deep
3/4" 1"
PPV100S16-FR___U1C-10
3/8-16 UNC;
17 deep
3/8-16 UNC;
17 deep
7/8-14 UNF 1/2-20 UNF 1/2-20 UNF 3/4" 1"
PPV100S16-FR___U2C-10 M10; 19 deep M10; 19 deep
G 1/2;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
3/4" 1"
PPV100S16-FR___J1C-10 M10; 19 deep M10; 19 deep Rc 1/2
Rc 1/4;
24 deep
Rc 1/4;
24 deep
3/4" 1"
26
E 2.907.1.0/02.14
82,55
H7
+
0,035
0
9
245,4
32
SAE J744-16-4-9T 16/32 DP
45°
106
6xM10
16
SAE "A"
SAE J744-82-2
82,55
H7
+
0,035
0
9
39
245,4
SAE J744-19-4-11T 16/32 DP
45°
106
6xM10
16
SAE "A"
SAE J744-82-2
2-hole
2-hole
deep
deep
Through drive "SAE A"
Through drive "SAE AB"
PPV100S16 Through drive options
SAE "A" 30° splined shaft
SAE "AB" 30° splined shaft
27
E 2.907.1.0/02.14
2
198
120
SW 17
71,5
0,247.5
273
57,2
27,8
198
16,5"DR"
90
120,5
85"S"
85"P"
30,2
13
58,7
13,5
28
122
46
25
37
1/4-20
16
"SP“
15T-16/32DP
(ANSI B 92.1)
36x8
M8 ;19
25
+
-
0,009
0,004
28
-
0,000
0,054
42
32x3,35
25,4
-
0,00
0,05
28,18
-
0
18
M8 ;19
46
122
146
176
13
101,6
-
0,00
0,05
9,7
46
120
122
140
176
13
9
52
100
-
0,000
0,054
120
2.1.25 PPV100S37
PPV100S37 with pressure control 01
Mounting flange and shaft options
"SP" SAE BB Splined shaft
"U1/U2/J1" SAE B Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Filling port
SW22
Flow adj.
screw
Drain port "DR"
Suction port
(Ø 32)
Discharge
port
(Ø 24)
Max.
deep
UNC Thd.
splined shaft
deep
deep
Pressure
adj. screw
SW13
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S37-FR___E1_-10 M12; 22 deep M12; 22 deep
M22x1.5;
13 deep
M14x1.5 ;
13 deep
M14x1.5 ;
13 deep
1" 1 1/4"
PPV100S37-FR___U1C-10
7/16-14 UNC;
20 deep
7/16-14 UNC;
20 deep
7/8-14 UNF 1/2-20 UNF 1/2-20 UNF 1" 1 1/4"
PPV100S37-FR___U2C-10 M12; 22 deep M10; 18 deep G 1/2; 17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1" 1 1/4"
PPV100S37-FR___J1C-10 M12; 22 deep M10; 18 deep Rc 1/2
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1" 1 1/4"
28
E 2.907.1.0/02.14
183.5
SW 17
SW22
SW 13
57
233
258.5
57.2
27,8
183.5
13,5
113,2
146
16,5"DR"
154
90
120,5
85"S"
85"P"
28
30,2
13
58,7
56
35
516-18 UNC
19
14T-1224DP
ANSI B 92.1)
40x10
60,0
51,0
32
+
0,018
0,000
35
+
-
0,018
0,288
M10; 22
40x8
56
48
31,7
+
0,05
0,00
35,1
+
0,18
0,00
5/16-18 UNC; 18
12,7
56
127
-
0,00
0,05
154,0
114,5
114,5
146,0
13
9
60
154,0
113,2
113,2
146,0
125
-
0,000
0,288
13
2.1.26 PPV100S37 with 4-hole mounting flange
PPV100S37 with pressure control 01
Mounting flange and shaft options
"SP" SAE C Splined shaft
"U1/U2/J1" SAE C Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Flow adj. screw
Drain port "DR"
Filling port
Discharge port
"P" (Ø 24)
Suction port
(Ø 19) "S"
"SP" splined shaft
Max.
deep
deep deep
Dec.
Pressure
adj. screw
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S37-FR___E1_-10 M12; 22 deep M10; 18 deep
M22x1.5;
13 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1" 1 1/4"
PPV100S37-FR___U1_-10
7/16-14 UNC;
20 deep
7/16-14 UNC;
20 deep
7/8-14 UNF 1/2-20 UNF 1/2-20 UNF 1" 1 1/4"
PPV100S37-FR___U2_-10 M12; 22 deep M10; 18 deep
G 1/2;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1" 1 1/4"
PPV100S37-FR___J1_-10 M12; 22 deep M10; 18 deep Rc 1/2
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1" 1 1/4"
29
E 2.907.1.0/02.14
2
222
80
SW14
16,5"DR"
130
85"S"
85"P"
33
162"PP"
91,0 239,3
SW13
SW14
164 "L"
57,2
16,5"DR"
90
150,5
171 "PP"
33
77
85"P"
PPV100S37 with remote pressure control 07
PPV100S37 with load sensing control 14
Remote control port
"PP"
Pressure
adj. screw
Load sensing port "L"
Load sensing
diff. pressure
adj. screw
Pressure
adj. screw
Remote control port
"PP"
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S37-FR___E1_-10 M12; 22 deep M10; 18 deep
M22x1.5;
13 deep
M14x1.5;
13 deep
M14x1.5 ;
13 deep
1" 1 1/4"
PPV100S37-FR___U1_-10
7/16-14 UNC;
20 deep
7/16-14 UNC;
20 deep
7/8-14 UNF 1/2-20 UNF 1/2-20 UNF 1" 1 1/4"
PPV100S37-FR___U2_-10 M12; 22 deep M10; 18 deep
G 1/2;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1" 1 1/4"
PPV100S37-FR___J1_-10 M12; 22 deep M10; 18 deep Rc 1/2
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1" 1 1/4"
30
E 2.907.1.0/02.14
236,5
40
24
82,55
H7
+
0,035
0
106
2xM10
18
SAE J744-16-4-9T 16/32 DP
SAE J744-82-2
SAE "A" 2-
236,5
40,5
24
82,55
H7
+
0,035
0
SAE "A" 2-
106
2xM10
18
SAE J744-19-4 11T 16/32 DP
SAE J744-82-2
261,5
101,6
H7
+
0,035
0
65
13
SAE "B" 2-
146
2xM12
25
SAE J744-22-4-13T 16/32 DP
SAE J744-101-2
261,5
101,6
H7
+
0,035
0
13
50
SAE "B" 2-
146
2xM12
25
SAE J744-25-4-15T 16/32 DP
SAE J744-101-2
273,5
16
127
H7
+
0,040
0
54
SAE "C" 4-
SAE J744-32-4-14T 12/24 DP
SAE J744-127-4
114,5
114,5
4xM12
37
PPV100S37 Through drive options
hole
hole
hole
hole
hole
deep
deep
deep
deep
deep
Through drive "SAE A"
Through drive "SAE AB"
Through drive "SAE B"
Through drive "SAE BB"
Through drive "SAE C"
SAE "A" 30° splined shaft
SAE "AB" 30° splined shaft
SAE "B" 30° splined shaft
SAE "BB" 30° splined shaft
SAE "C" 30° splined shaft
31
E 2.907.1.0/02.14
2
78,5
223
120
SW 17
SW22
SW 13
13
271
300
27,8
223
57,2
140,5
102
85"P"
85"S"
91
69,9
35,7
19"DR"
28
13,5
122
46
25
37
1/4-20 UNC Thd.
16
"SP"
15T-16/32DP
(ANSI B 92.1)
36x8
M8 ;19
25
+
-
0,009
0,004
28
-
0,000
0,054
42
32x3,35
25,4
-
0,00
0,05
28,18
-
0
18
M8 ;19
46
122
146
176
13
101,6
-
0,00
0,05
9,7
46
120
122
140
176
13
9
52
100
-
0,000
0,054
120
2.1.27 PPV100S56 with 2-hole mounting flange
PPV100S56 with pressure control 01
Mounting flange and shaft options
"SP" SAE BB Splined shaft
"U1/U2/J1" SAE B Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Filling port
Flow adj.
screw
Drain port "DR"
Suction port
(Ø 38) "S"
Discharge
port
(Ø 26) "P"
Max.
deep
splined shaft
deep
deep
Pressure
adj. screw
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S56-FR___E1_-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1" 1 1/2"
PPV100S56-FR___U1_-10
7/16-14 UNC;
20 deep
1/2-13 UNC 7/8-14 UN
1 1/16-12
UNF
1/2-20 UNF
1" 1 1/2"
PPV100S56-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1" 1 1/2"
PPV100S56-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1" 1 1/2"
32
E 2.907.1.0/02.14
56
35
5/16-18 UNC Thd.
19
"SP"
14T-12/24DP
(ANSI B 92.1)
40x10
60,0
51,0
32
+
0,018
0,000
35
+
-
0,018
0,288
M10; 22
40x8
56
48
31,7
+
0,05
0,00
35,1
+
0,18
0,00
5/16-18 UNC; 18
12,7
56
127
-
0,00
0,05
154
114,5
114,5
146
13
9
60
154,0
113,2
113,2
146,0
125
-
0,000
0,288
13
53,5
245,8
274,8
198
SW 17
SW22
SW 13
13
27,8
198
57,2
140,5
102
85"P"
85"S"
91
69,9
35,7
146
28
13,5
154
19"DR"
2.1.28 PPV100S56 with 4-hole mounting flange
PPV100S56 with pressure control 01
Mounting flange and shaft options
"SP" SAE C Splined shaft
"U1/U2/J1" SAE C Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Flow adj.
screw
Drain port "DR"
Filling port
Discharge
port
"P"
Suction port "S"
splined shaft
Max.
deep
deep deep
Flow adjustment
Press.
compensator
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S56-FR___E1_-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1" 1 1/2"
PPV100S56-FR___U1_-10
7/16-14 UNC;
20 deep
1/2-13 UNC 7/8-14 UN
1 1/16-12
UNF
1/2-20 UNF 1" 1 1/2"
PPV100S56-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1" 1 1/2"
PPV100S56-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1" 1 1/2"
33
E 2.907.1.0/02.14
2
184,30"PP"
244,30
SW14
141
85"P"
85"S"
91
19"DR"
36
186,30 "L"
193,30 "PP"
261,80
SW14
SW13
161,5
94
19 "DR"
36
85 "P"
85 "S"
80
PPV100S56 with remote pressure control 07
PPV100S56 with load sensing control 14
Remote control port
"PP"
Pressure
adj. screw
Load sensing port "L"
Load sensing
diff. pressure
adj. screw
Pressure
adj. screw
Remote control port
"PP"
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S56-FR___E1_-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1" 1 1/2"
PPV100S56-FR___U1_-10
7/16-14 UNC;
20 deep
1/2-13 UNC 7/8-14 UN
1 1/16-12
UNF
1/2-20 UNF 1" 1 1/2"
PPV100S56-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1" 1 1/2"
PPV100S56-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1" 1 1/2"
34
E 2.907.1.0/02.14
82,55
H7
+
0,035
0
28
40
253
SAE "A" 2-
106
2xM10
18
SAE J744-16-4-9T 16/32 DP
SAE J744-82-2
82,55
H7
+
0,035
0
253
28
40,5
SAE "A" 2-
106
2xM10
18
SAE J744-19-4 11T 16/32 DP
SAE J744-82-2
278
101,6
H7
+
0,035
0
65
13
SAE "B" 2-
146
2xM12
25
SAE J744-22-4-13T 16/32 DP
SAE J744-101-2
278
101,6
H7
+
0,035
0
13
50
SAE "B" 2-
146
2xM12
25
SAE J744-25-4-15T 16/32 DP
SAE J744-101-2
290
16
127
H7
+
0,040
0
54
SAE "C" 4-
SAE J744-32-4-14T 12/24 DP
SAE J744-127-4
114,5
114,5
4xM12
37
PPV100S56 Through drive options
hole
hole
hole
hole
hole
deep
deep
deep
deep
deep
Through drive "SAE A"
Through drive "SAE AB"
Through drive "SAE B"
Through drive "SAE BB"
Through drive "SAE C"
SAE "A" 30° splined shaft
SAE "AB" 30° splined shaft
SAE "B" 30° splined shaft
SAE "BB" 30° splined shaft
SAE "C" 30° splined shaft
35
E 2.907.1.0/02.14
2
56
35
(ANSI B 92.1)
19
"SP"
14T-12/24DP
5/16-18UNC
60
40x10
32
+
+
0,018
0,002
35
+
-
0,018
0,288
50
M10; 22
56
40x8
50
31,75
-
0,00
0,05
35,32
-
0,00
0,18
5/16 - 18 UNC
19
143
114,5
114,5
155
12,7
56
127
18
190
141,4
141,4
192
160,0
-
0,000
0,063
9
60
18
SW 22
SW 17
A
SW 13
19"DR"
190
192
18
35
18
61
270
296,5
31,8
223,5
66,7
102"P"
102"S"
150.5
114
42,9
223.5
77,8
2.1.29 PPV100S71
PPV100S71 with pressure control 01
Mounting flange and shaft options
"SP" SAE C Splined shaft
"U1/U2/J1" SAE C Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Filling port
Flow adj.
screw
Drain port "DR"
Suction port "S"
(Ø 38)
View - A
Discharge port "P"
(Ø 34)
Max.
deep
splined shaft
deep
deep
Pressure
adj. screw
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S71-FR___E1_-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/4" 2"
PPV100S71-FR___U1_-10
1/2-13 UNC;
21 deep
1/2-13 UNC;
21 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/4" 2"
PPV100S71-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/4" 2"
PPV100S71-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/4" 2"
36
E 2.907.1.0/02.14
176,0 "PP"
237,5
SW 14
150.5
148.5"PP"
102"P"
102"S"
43,5
19"DR"
180 "L"
187" PP"
255,5
SW 13
SW 14
19"DR"
114.5
143
167,5
105
43,5
91
163.5 "L" "PP"
PPV100S71 with remote pressure control 07
PPV100S71 with load sensing control 14
Remote control port
"PP"
Pressure
adj. screw
Load sensing port "L"
Load sensing
diff. pressure
adj. screw
Pressure
adj. screw
Remote
control
port "PP"
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S71-FR___E1_-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/4" 2"
PPV100S71-FR___U1_-10
1/2-13 UNC;
21 deep
1/2-13 UNC;
21 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/4" 2"
PPV100S71-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/4" 2"
PPV100S71-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/4" 2"
37
E 2.907.1.0/02.14
2
274,5
40
82,55
H7
+
0,035
0
26
SAE "A" 2-
106
2xM10
18
SAE J744-16-4-9T 16/32 DP
SAE J744-82-2
40,5
82,55
H7
+
0,035
0
274,5
26
SAE "A" 2-
SAE J744-82-2
106
2xM10
18
SAE J744-19-4 11T 16/32 DP
299,5
101,6
H7
+
0,035
0
65
13
SAE "B" 2-
SAE J744-22-4-13T 16/32 DP
SAE J744-101-2
146
2xM12
25
101,6
H7
+
0,035
0
13
325
50
SAE "B" 2-
SAE J744-101-2
146
2xM12
25
SAE J744-25-4-15T 16/32 DP
311,5
16
127
H7
+
0,040
0
54
SAE "C" 4-
SAE J744-32-4-14T 12/24 DP
SAE J744-127-4
114,5
114,5
4xM12
37
PPV100S71 Through drive options
hole
hole
hole
hole
hole
deep
deep
deep
deep
deep
Through drive "SAE A"
Through drive "SAE AB"
Through drive "SAE B"
Through drive "SAE BB"
Through drive "SAE C"
299,5
101,6
H7
+
0,035
0
65
13
SAE "B" 2-
SAE J744-22-4-13T 16/32 DP
SAE J744-101-2
146
2xM12
25
SAE "A" 30° splined shaft
SAE "AB" 30° splined shaft
SAE "BB" 30° splined shaft
SAE "C" 30° splined shaft
SAE "B" 30° splined shaft
38
E 2.907.1.0/02.14
A
SW 13
SW 27
SW 17
M27×2
23"DR"
287
62,5
322
243"S""P"
31,8
210
210
18
66,7
163
112,5"P"
112,5"S"
88,9
50,8
118,5
35
62
38
(ANSI B 92.1)
28
"SP"
17T-12/24DP
7/16-14UNC
80
56x12
40
+
+
0,018
0,002
43
+
-
0,018
0,288
M12; 28
62
45x12
38,1
-
0,00
0,05
42,36
-
0,00
0,18
1/16-14 UNC; 28
210
161,6
161,6
210
12,7
62
152,4
17,5
210
158,4
158,4
210
9
80
180
17,5
2.1.30 PPV100S100
PPV100S100 with pressure control 01
Mounting flange and shaft options
"SP" SAE CC Splined shaft
"U1/U2/J1" SAE D Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Flow adj.
screw
Drain port "DR"
Filling port
Discharge port
"P" (Ø 34)
Suction port "S"
(Ø63)
View - A
splined shaft
Max.
deep
deep
deep
Pressure
adj. screw
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S100-FR___E1D-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/4" 2 1/2"
PPV100S100-FR___U1D-10
1/2-13 UNC;
21 deep
1/2-13 UNC;
21 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/4" 2 1/2"
PPV100S100-FR___U2D-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/4" 2 1/2"
PPV100S100-FR___J1D-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/4" 2 1/2"
39
E 2.907.1.0/02.14
2
249
A
SW 14
23"DR"
158,4
210
163
112,5"P"
112,5"S"
118,5
42,5
188"PP"
154"PP"
267,3
A
SW 13
SW 14
23"DR"
158,4
210
112,5 "P"
112,5 "S"
118,5
192 "L"
199 "PP"
169"L""PP"
42,5
90
173
PPV100S100 with remote pressure control 07
PPV100S100 with load sensing control 14
Remote control port "PP"
Pressure
adj. screw
Load sensing port "L"
Load sensing
adj. screw
Pressure adj. screw
Remote
control
port "PP"
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S100-FR___E1D-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/4" 2 1/2"
PPV100S100-FR___U1_-10
1/2-13 UNC;
21 deep
1/2-13 UNC;
21 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/4" 2 1/2"
PPV100S100-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/4" 2 1/2"
PPV100S100-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/4" 2 1/2"
40
E 2.907.1.0/02.14
82,55
H7
+
0,035
0
26
42
300
SAE "A" 2-
106
2xM10
18
SAE J744-16-4-9T 16/32 DP
SAE J744-82-2
82,55
H7
+
0,035
0
26
42,5
300
SAE "A" 2-
SAE J744-82-2
SAE J744-19-4 11T 16/32 DP
106
2xM10
18
101,6
H7
+
0,035
0
67
13
325
SAE "B" 2-
SAE J744-22-4-13T 16/32 DP
SAE J744-101-2
146
2xM12
25
13
67,5
101,6
H7
+
0,035
0
325
SAE "B" 2-
SAE J744-101-2
SAE J744-25-4-15T 16/32 DP
146
2xM12
25
16
127
H7
+
0,040
0
337
57
SAE "C" 4-
SAE J744-32-4-14T 12/24 DP
SAE J744-127-4
114,5
114,5
4xM12
37
14
152,4
H7
+
0,040
0
337
60
SAE "D" 4-
SAE J744-38-4-17T 12/24 DP
SAE J744-152-4
161,6
161,6
4xM20
37
PPV100S100 Through drive options
hole
hole
hole
hole
hole
hole
deep
deep
deep
deep
deep
deep
Through drive "SAE A" Through drive "SAE AB"
Through drive "SAE B"
Through drive "SAE BB"
Through drive "SAE C"
Through drive "SAE D"
Splined shaft "SAE CC"
SAE "A" 30° splined shaft
SAE "AB" 30° splined shaft
SAE "B" 30° splined shaft
SAE "BB" 30° splined shaft
SAE "C" 30° splined shaft
SAE "CC" 30° splined shaft
41
E 2.907.1.0/02.14
2
75
45
(ANSI B 92.1)
32
"SP"
13T-8/16DP
1/2-13 UNC
92
70x14
45
+
+
0,018
0,002
48,5
+
-
0,018
0,288
M16; 36
75
56x14
44,5
-
0,00
0,05
49,39
-
0,00
0,18
1/2-13 UNC; 32
210
161,6
161,6
220
12,7
75
152,4
22
210
158,4
158,4
210
9
92
180
22
A
SW 27
SW 19
SW 13
M27×2
26"DR"
210
220
18
74
0,321.5
35
22
266,5"S""P"
31,8
66,7
345,5
123"P"
123"S"
172.5
129
50,8
88,9
2.1.31 PPV100S145
PPV100S145 with pressure control 01
Mounting flange and shaft options
"SP" SAE D Splined shaft
"U1/U2/J1" SAE D Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Filling port
Case drain port
5 hex. soc.
Flow
adj. screw
Drain port "DR"
Suction port "S"
(Ø 63)
View - A
Discharge
port "P"
(Ø 34)
Max.
deep
splined shaft
deep deep
Pressure
adj. screw
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S145-FR___E1D-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/4" 2 1/2"
PPV100S145-FR___U1_-10
1/2-13 UNC;
21 deep
1/2-13 UNC;
21 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/4" 2 1/2"
PPV100S145-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/4" 2 1/2"
PPV100S145-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/4" 2 1/2"
42
E 2.907.1.0/02.14
273
210
SW 14
26"DR"
158,4
74
211,5"PP"
172.5
129
160,5"PP"
123"P"
123"S"
46
290,8
A
SW 14
SW 13
26"DR"
158.4
210
215,5"L"
222,5"PP"
123"P"
123"S"
179,5
129
46
93,5
175,5"L""PP"
PPV100S145 with remote pressure control 07
PPV100S145 with load sensing control 14
Remote control port "PP"
Pressure
adj. screw
Load sensing port "L"
Load sensing
adj. screw
Pressure
compensator
adj. screw
Remote
control
port "PP"
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S145-FR___E1D-10
M12; 22 deep M12; 22 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/4" 2 1/2"
PPV100S145-FR___U1_-10
1/2-13 UNC;
21 deep
1/2-13 UNC;
21 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/4" 2 1/2"
PPV100S145-FR___U2_-10
M12; 22 deep M12; 22 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/4" 2 1/2"
PPV100S145-FR___J1_-10
M12; 22 deep M12; 22 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/4" 2 1/2"
43
E 2.907.1.0/02.14
2
PPV100S145 Through drive options
Through drive "SAE A" Through drive "SAE AB"
Through drive "SAE B" Through drive "SAE BB"
Through drive "SAE C"
Through drive "SAE D"
Splined shaft "SAE CC"
Through drive "SAE D"
82,55
H7
+
0,035
0
323,5
26
42
SAE "A" 2-
SAE J744-16-4-9T 16/32 DP
106
2xM10
18
SAE J744-82-2
82,55
H7
+
0,035
0
323,5
26
42,5
SAE "A" 2-
SAE J744-82-2
SAE J744-19-4 11T 16/32 DP
106
2xM10
18
SAE "A" 30° splined shaft
hole
hole
deep
deep
SAE "AB" 30° splined shaft
67,5
13
101,6
H7
+
0,035
0
348,5
SAE "B" 2-
SAE J744-101-2
146
2xM12
25
SAE J744-25-4-15T 16/32 DP
hole
deep
SAE "BB" 30° splined shaft
16
127
H7
+
0,040
0
360,5
67
SAE "C" 4-
SAE J744-32-4-14T 12/24 DP
SAE J744-127-4
114,5
114,5
4xM12
37
hole
deep
SAE "C" 30° splined shaft
14
152,4
H7
+
0,040
0
360,5
60
SAE "D" 4-
SAE J744-38-4-17T 12/24 DP
SAE J744-152-4
161,6
161,6
4xM20
37
hole
deep
SAE "CC" 30° splined shaft
15
152,4
H7
+
0,040
0
383,5
73
SAE "D" 4-
SAE J744-44-4-13T 8/16 DP
SAE J744-152-4
161,6
161,6
4xM20
40
hole
deep
SAE "D" 30° splined shaft
101,6
H7
+
0,035
0
67
13
348,5
SAE "B" 2-
SAE J744-22-4-13T 16/32 DP
SAE J744-101-2
146
2xM12
25
hole
deep
SAE "B" 30° splined shaft
44
E 2.907.1.0/02.14
75
45
(ANSI B 92.1)
32
"SP"
13T-8/16DP
1/2-13 UNC
92
70x14
45
+
+
0,018
0,002
48,5
+
-
0,018
0,288
M16; 36
75
56x14
44,5
-
0,00
0,05
49,39
-
0,00
0,18
1/2-13 UNC; 32
210
161,6
161,6
220
12,7
75
152,4
22
210
158,4
158,4
210
9
92
180
22
A
297.5
SW 19
SW 27
M27×2
SW 13
27,5"DR"
210
220
18
35
86
0,352.5
24
297,5"S""P"
36,5
79,4
384,5
190138
129"P"
129"S"
61.9
106,4
2.1.32 PPV100S180
PPV100S180 with pressure control 01
Mounting flange and shaft options
"SP" SAE D Splined shaft
"U1/U2/J1" SAE D Mounting flange
"K1" ISO Keyed shaft
"E1" ISO Mounting flange
"K2" ISO Keyed shaft
Flow adj. screw
Drain port "DR"
Filling port
Discharge
port
"P" (Ø44)
Suction port "S"
(Ø76)
splined shaft
Max.
deep
deep deep
Pressure
adj. screw
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S180-FR___E1D-10
M16; 29 deep M16; 29 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/2" 3"
PPV100S180-FR___U1_-10
5/8-11 UNC;
29 deep
5/8-11 UNC;
29 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/2" 3"
PPV100S180-FR___U2_-10
M16; 29 deep M16; 29 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/2" 3"
PPV100S180-FR___J1_-10
M16; 29 deep M16; 29 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/2" 3"
View - A
45
E 2.907.1.0/02.14
2
299,8
86,0
SW 14
27,5"DR"
158,4
210
190138
129"P"
129"S"
40
168,5"PP"
238,5"PP"
317,8
A
SW 13
SW 14
27,5 "DR"
158,4
210
190138
129 "P"
129 "S"
40
183,5"L""PP"
249,5 "PP"
242,5 "L"
87,5
PPV100S180 with remote pressure control 07
PPV100S180 with load sensing control 14
Remote control port
"PP"
Pressure
adj. screw
Load sensing
port "L"
Load sensing
adj. screw
Pressure
adj. screw
Remote control port "PP"
Pump type
Thread size
Dimensions to
SAE J 518 (full flange)
Discharge
port
"P"
Suction port
"S"
Drain port
"DR"
Remote
control port
"PP"
Load sensing
port
"L" "P" "S"
PPV100S180-FR___E1_-10
M16; 29 deep M16; 29 deep
M27x2;
15 deep
M14x1.5;
13 deep
M14x1.5;
13 deep
1 1/2" 3"
PPV100S180-FR___U1_-10
5/8-11 UNC;
29 deep
5/8-11 UNC;
29 deep
1 1/16-12 UN 1/2-20 UNF 1/2-20 UNF 1 1/2" 3"
PPV100S180-FR___U2_-10
M16; 29 deep M16; 29 deep
G 3/4;
17 deep
G 1/4;
24 deep
G 1/4;
24 deep
1 1/2" 3"
PPV100S180-FR___J1_-10
M16; 29 deep M16; 29 deep Rc 3/4
Rc 1/4;
24 deep
Rc 1/4;
24 deep
1 1/2" 3"
46
E 2.907.1.0/02.14
82,55
H7
+
0,035
0
362,5
26
42
SAE "A" 2-
SAE J744-16-4-9T 16/32 DP
106
2xM10
18
SAE J744-82-2
82,55
H7
+
0,035
0
362,5
26
42,5
SAE "A" 2-
SAE J744-82-2
SAE J744-19-4 11T 16/32 DP
106
2xM10
18
101,6
H7
+
0,035
0
67
13
387,5
SAE "B" 2-
SAE J744-22-4-13T 16/32 DP
SAE J744-101-2
146
2xM12
25
67,5
13
101,6
H7
+
0,035
0
387,5
SAE "B" 2-
SAE J744-101-2
146
2xM12
25
SAE J744-25-4-15T 16/32 DP
16
127
H7
+
0,040
0
399,5
67
SAE "C" 4-
SAE J744-32-4-14T 12/24 DP
SAE J744-127-4
114,5
114,5
4xM12
37
14
152,4
H7
+
0,040
0
399,5
60
SAE "D" 4-
SAE J744-38-4-17T 12/24 DP
SAE J744-152-4
161,6
161,6
4xM20
37
15
152,4
H7
+
0,040
0
422,5
73
SAE "D" 4-
SAE J744-44-4-13T 8/16 DP
SAE J744-152-4
161,6
±0,2
161,6
±0,2
4xM20
40
PPV100S180 Through drive options
hole
hole
hole
hole
hole
hole
hole
deep
deep
deep
deep
deep
deep
deep
Through drive "SAE A" Through drive "SAE AB"
Through drive "SAE B" Through drive "SAE BB"
Through drive "SAE C"
Through drive "SAE D"
Splined shaft "SAE CC"
Through drive "SAE D"
SAE "A" 30° splined shaft
SAE "B" 30° splined shaft
SAE "C" 30° splined shaft
SAE "CC" 30° splined shaft
SAE "D" 30° splined shaft
SAE "AB" 30° splined shaft
SAE "BB" 30° splined shaft