E 7.719.0/09.07
103
Indicators
Clogging Indicators for
Process Filters
1. TECHNICAL
SPECIFICATIONS
1.1 GENERAL
HYDAC clogging indicators are
designed to indicate visually and/or
electrically when the filter elements must
be cleaned or changed.
The use of clogging indicators
guarantees both the operational safety
of the system and the efficient utilisation
of the filter elements.
1.2 SEALS
V (=Viton) or T (=FEP encapsulated)
2. QUICK SELECTION:
CLOGGING INDICATORS ACCORDING TO FILTER TYPE
Please select from the table the clogging indicator required for your filter.
1.4 SPECIAL INDICATORS
Electrical ATEX indicators:
Optional: electrical indicator for
process filters for use in potentially
explosive atmospheres subject to the
ATEX equipment directive 94/9/EC
and the ATEX operator directive
1999/92/EC.
1.5 TORQUE VALUES - DIFFERENTIAL
PRESSURE INDICATORS
Note:
The clogging indicators must only be
tightened or adjusted on the spanner
flats.
z PVD..B.1: SW27
z PVD..C.0: SW30
z PVD..D.0/L...: SW30
max. torque value: 100 Nm
1.3 CONSTRUCTION
Differential pressure indicators are
used on all process filters. They react
to the pressure differential between the
filter inlet and filter outlet which rises
as the level of contamination in the
element increases.
The simplest fitting of the differential
pressure indicator:
G ½" cavity
(to HYDAC works standard HN 28-22)
The differential pressure indicator type
V01 is piped up separately.
For duplex filter housings the
differential pressure indicators are
connected using an adaptor block.
Clean side
Contaminated
side
Type Filter types
PRFL
PRFLD
PRFS
PRFSD
PFL
PFM
PFH
EDF PMRF
PMRFD
PVD ..B
z z z z z
PVD ..C
z z z z z
PVD ..D
z z z z z
V01...VZ
z z
on request
z
Differential pressure gauge
z z z