EN 5.999.5.1/07.24
4
General specications
MTTF
D
150 - 1200 years, assessment according to DIN EN ISO 13849-1:2016;
Table C.1, Conrmation of ISO 13849-2:2013; Tables C.1 and C.2
Ambient temperature -20 °C to +60 °C
Installation position User-denable
Weight 1 solenoid = 1.5 kg 2 solenoids = 2.0 kg
Material Valve casing: Cast iron
Coil housing: Steel
Type label: Aluminium
Surface coating Valve casing: Phosphate-plated
Coil housing: ZnNi coating
Hydraulic specications
Operating pressure Ports: P, A, B p
max
100 bar
Ports: T p
max
30 bar
Control pressure range 0 - 16 bar 0 - 26 bar 0 - 45 bar
Max. ow rate 15 l/min
Pressure uid Mineral oil according to DIN 51524 part 1, 2 and 3
Temperature range of operating uid -20 °C to +80 °C
Viscosity range min. 15 to max. 400 mm²/s
Filtration, max. permitted contamination level ISO 4406 class 18/16/13 acc. to. ISO 4406 or better
Max. switching frequency 7,000 1/h
Mean hysteresis <6.0 % of p
max
control
Mean repeatability ±1.5 % of p
max
control
Sealing material FKM (standard), NBR (optional)
Electrical characteristics
Response time Energised: approx. 50 - 100 ms
The switching time specications are largely dependent on the valve’s pressure, ow rate
and the application.
Type of voltage DC voltage
Nominal voltage 12 V 24 V
Voltage tolerance ±10 %
Pilot current 0 - 2250 mA (2.7 Ω) 0 - 1600 mA (5 Ω)
Dither frequency 80 to 150 Hz (100 recommended)
Duty cycle 100 %
Protection class according to DIN EN 60529 With electrical connection G = IP65²
With electrical connection N = IP65²
¹ See "Conditions and Instructions for Valves" in brochure 53.000.
² If cable socket mounted corretly.
TECHNICAL DATA
1)