1
EN 5.126.3/10.19
Proportional
Flow Controller
Poppet type, pilot-operated,
Normally closed
UNF Cartridge – 350 bar
PWS10Z-11
up to 100 l/min
up to 350 bar
The proportional valve is a pilot-
operated, normally closed, spring-loaded
poppet-type ow control valve.
It is non-compensated and its function is
to smoothly control the ow from port 2
to port 1.
The energization of the coil opens the
pilot stage and oil ows across an orice
to the back of the main piston. The
resulting pressure dierential causes the
main piston to follow the pilot stage and
allows a nominal ow. If de-energized,
there is free ow from port 1 to port 2
(see dp/-performance). If energized, ow
from port 1 to port 2 is not possible.
FEATURES
z When combined with a pressure compensator the proportional ow controller can
be used as a 2-way ow regulator – for example when required to lift/lower variable
loads at the same velocity.
z Stepless adjustment of the ow, depending on the coil current.
z Excellent stability throughout the entire ow range
z Excellent dynamic performance
z Coil seals protect the solenoid system
z Optional: Soft shift function with extended switching times possible
z On request: mechanical adjustment of one point of the curve (Version 11, not in
combination with option M)
z Exposed surfaces Zinc-Nickel plated for inreased corrosion protection
(1.000h Salt spray test)
FUNCTION
SPECIFICATIONS*
Operating pressure: max. 350 bar
Nominal ow: max. 100 l/min
Internal leakage: leakage-free
max. 5 drops/min (0.25 cm³/min) at 350 bar
Media operating temperature range: min. -20 °C to max. +100 °C
Ambient temperature range: min. -20 °C to max. + 60 °C
Operating uid: Hydraulic oil to DIN 51524 Part 1, 2 and 3
Viscosity range: min. 10 mm²/s to max. 420 mm²/s
Filtration: Class 19/17/14 to ISO 4406 or cleaner
MTTF
d
: 150 - 1200 years,
according to DIN EN ISO 13849-1
Installation: No orientation restrictions
Material: Valve body: steel
Piston: hardened and
ground steel
Seals: NBR (standard)
FKM (optional, media
temperature range
-20 °C to +100 °C)
Back-up rings: PTFE
Coil: steel / polyamide
Cavity: FC10-2
Weight: 0.5 kg
Electrical data
Control current: 850 mA, 18.0 Ohm (24 Volt)
1750 mA, 4.1 Ohm (12 Volt)
Dither frequency: 120 – 250 Hz (120 Hz recommended)
Hysteresis with dither: 4 - 6 % of Q
max
(für I < 70 % of I
nom
)
Repeatability: ≤ 1.5 % of Q
max
Reversal error: ≤ 2 % of I
nom
Response sensitivity: ≤ 1 % of I
nom
Type of coil: Coil (12 or 24) P ...50-1836
Note
In order to achieve optimal function, any trapped air should be vented using the
bleed screw on the face of the pole tube.
* see "Conditions and instructions for valves" in brochure 53.000