1
EN 5.120.8/05.20
Needle Valves
with and without
reverse ow check
direct-acting
Manifold Mounted – 350 bar
DVP-/ DRVP- 06 to 40
FEATURES
z For regulating the speed of loads
z For ne adjustment and shut-o of the ow
z For system-related damping in hydraulic circuits
z To release pressure from accumulator systems
z As an emergency drain for lowering a load
z Spindle patented secured before complete loosening
z An Allen set-screw locks the setting of the knob
z Choice of nine sizes ensures best possible adaptability to the system
z Optional nickel-plated version available (up to size 12)
SPECIFICATIONS*
Operating pressure: max. 350 bar
Nominal ow: DVP, DRVP-06 max. 20 l/min
DVP, DRVP-08 max. 50 l/min
DVP, DRVP-10 max. 60 l/min
DVP, DRVP-12 max. 90 l/min
DVP, DRVP-16 max. 180 l/min
DVP, DRVP-20 max. 300 l/min
DVP, DRVP-25 max. 300 l/min
DVP, DRVP-30 max. 300 l/min
DRVP-40 max. 300 l/min
Cracking pressure (on DRVP): 0.5 bar
Media operating temperature range: min. -20 °C to max. +80 °C
Ambient temperature range: min. -20 °C to max. +80 °C
Operating uid: Hydraulic oil to DIN 51524 Part 1, 2 and 3
Viscosity range: min. 2.8 mm²/s to max. 800 mm²/s
Filtration: Class 21/19/16 according to ISO 4406 or
cleaner
MTTF
d
: 150 - 1200 years,
according to DIN EN ISO 13849-1
Installation: No orientation restrictions, preferably
horizontal
Materials: Valve body: steel
Piston: hardened and
ground steel
Seals: FKM (standard)
Back-up rings: PTFE
Weight: DVP 06 = 0.2 kg DRVP 06 = 0.3 kg
DVP 08 = 0.4 kg DRVP 10 = 0.8 kg
DVP 10 = 0.6 kg DRVP 12 = 1.1 kg
DVP 12 = 1.0 kg DRVP 16 = 2.5 kg
DVP 16 = 1.7 kg DRVP 25 = 6.7 kg
DVP 20 = 3.6 kg DRVP 30 = 3.9 kg
DVP 25 = 5.5 kg DRVP 40 = 17.5 kg
DVP 30 = 7.5 kg
The DVP is a manifold mounted ow
control valve which controls the ow
rate by adjusting the cross-section.
The ow rate is therefore dependent on
the pressure dierential and viscosity.
Starting with the throttle spindle in the fully
closed position, the ow rate increases
in accordance with the appropriate curve
as the control knob is turned. The ow is
controlled in both directions.
The scale and coloured rings on the top of
the control knob enable accurate repeat
setting. The DRVP is a manifold mounted
ow control valve which allows the same
ne ow adjustment, but in one direction
only. Unrestricted ow in the reverse
direction is via the built-in check valve
(cracking pressure 0.5 bar).
up to 300 l/min
up to 350 bar
FUNCTION
DVP
Control knob
Control knob
Set-screw
Set-screw
Control spindle
Control spindle
Housing
Housing Valve
seat
Closing
cone
Spring
Throttle opening
Throttle opening
DRVP
* see "Conditions and instructions for valves" in brochure 53.000