1
E 7.301.18/11.16
Spin-On Filter MF/MFD
up to 300 l/min, up to 8 bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter consists of a lter head with
built-in bypass valve and a screw-on
lter cartridge.
Standard equipment:
with bypass valve
1.2 FILTER CARTRIDGES
MG: Cartridge connection thread,
to ISO 228
Sealing on inside
(Note: the seal on the
0080 MA cartridge is also
on the inside!)
MA: Cartridge connection,
UN thread sealing
on the outside
1.4 SEALS
NBR (=Perbunan)
1.5 INSTALLATION
Inline lter
1.6 SPECIAL MODELS AND
ACCESSORIES
Without bypass or with other bypass
cracking pressures
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.3 FILTER SPECIFICATIONS
Nominal pressure 8 bar
Temperature range -30 °C to +100 °C
Pressure setting of clogging indicator: p
a
Type E: 0 to 16 bar
Type F: 1.5 or 2 bar
Type UE: 0 to -1.0 bar
Type UF: -0.2 bar
Type of clogging indicator VMF (return line indicator)
Material of lter head Aluminium
Material of lter cartridge Sheet steel
Bypass cracking pressure MF 80: 1.7 bar (standard)
MF 160/180: 2 bar (standard)
MFD 1.7 bar (standard)
Symbol for hydraulic systems
MF
80
MF
160
MF
180
MFD
160
MFD
180
E 7.301.18/11.16
Seals Seals
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils to DIN 51524
Lubrication oils DIN 51517, API,
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506
Biodegradable operating uids
VDMA 24568 HETG, HEES, HEPG
Fire-resistant uids HFA, HFB, HFC
and HFD
Operating uids with high water
content (>50% water content) on
request
E 7.301.18/11.16
2
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
0160 MA 010 BN
Size
0080, 0160, 0180
Type
MG for lters with cartridge connection G (= thread to ISO 228);
paper lter material only (exception: MF 80: 20 BN)
MA for lters with cartridge connection U (= UN thread)
Filtration rating in µm
BN 003, 005, 010, 020 (for MF 80: MA = only 10 µm; MG = 20 µm)
P 010
Filter material
BN, P
2.2 REPLACEMENT CARTRIDGE
2.3 REPLACEMENT CLOGGING INDICATOR VMF 2 F . X
Type of indicator
VMF Return line pressure indicator
Pressure setting
2 2 bar standard for size 160/180
(see Point 1.3)
1.5 1.5 bar standard for size 80
Type of clogging indicator
F (see Point 2.1)
Modication number
X the latest version is always supplied
Filter type
MF (all sizes; 1 lter cartridge)
MFD (sizes 160 and 180; 2 lter cartridges)
Filter material
BN Betamicron
®
P Paper (only MF 80 and MF/MFD 160)
Size of lter or cartridge
MF: 80, 160, 180
MFD: 160, 180
Operating pressure
A 8 bar
Type of cartridge connection
G thread to ISO 228 (G ¾ on size 80; G 1¼ on size 160)
U UN thread (1-12 UNF on size 80, 1½ x 16 UN-2B on size 160/180)
Type and size of port
MF BN 160 A U E 10 F 1 .X /-KB
Filtration rating in µm
BN 3, 5, 10, 20
P 10
Type of clogging indicator
A steel blanking plug in indicator port
E pressure gauge
pressure indicators
F pressure switch for other clogging indicators
UE vacuum gauge
vacuum indicators
see brochure no. 7.050../..
UF vacuum switch
Type code
0
1 - 8 see Point 2.4
Modication number
X the latest version is always supplied
Supplementary details
B. cracking pressure of bypass (e.g. B0.2 = 0.2 bar; B0.25 = 0.25 bar)
KB without bypass valve (only for size 160/180)
Type Connection Filter size
80 160 180
C G ¾ MF
E G1 ¼ MF MF
F G1 ½ MFD MFD
3
E 7.301.18/11.16
2.4 MOUNTING POSITION OF THE CLOGGING INDICATOR
MF 80 MF 160/180 MFD 160/180
For MF lters
Type Mounting position of Application of Type of Specials
code clogging indicator complete lter indicator
0.X Without clogging indicator, screw plug in all indicator ports
1.X Filter inlet: on left Return line Pressure indicator
lter
2.X Filter inlet: on right Return line Pressure indicator
lter
3.X Filter outlet: on left Suction lter Vacuum indicator - with byp. cracking press. 0.2 bar (.../-B0.2)
- without bypass valve (.../-KB)
--> only BG160/180
4.X Filter outlet: on right Suction lter Vacuum indicator - with byp. cracking press. 0.2 bar (.../-B0.2)
- without bypass valve (.../-KB)
--> only BG160/180
5.X Filter inlet & outlet: on left Pressure lter Pressure and
vacuum indicator
6.X Filter inlet & outlet: on right Pressure lter Pressure and
vacuum indicator
7.X Filter inlet: on right and left Return line lter Pressure indicator
8.X Filter outlet: on right and left Suction lter Vacuum indicator Only for sizes 160 und 180, on versions:
- with byp. cracking press. 0.2 bar (.../-B0.2)
- without bypass valve (.../-KB)
For MFD lters
Type Mounting position of Application of Type of Specials
code clogging indicator complete lter indicator
0.X Without clogging indicator, screw plug in all indicator ports
1.X Filter inlet: on right Return line lter Pressure indicator
3.X Filter outlet: on right Suction lter Vacuum indicator Only on versions:
- with byp. cracking press. 0.2 bar (.../-B0.2)
- without bypass valve (.../-KB)
5.X Filter inlet & outlet: on right Pressure lter Pressure and
vacuum indicator
2.5 CARTRIDGE SELECTION TABLE
Filter type MF
Size 80 Cartridge
MF P 80 AGC 10 ... 0080 MG 010 P
MF BN 80 AUC 10 ... 0080 MA 010 BN
MF BN 80 AGC 20 ... 0080 MG 020 BN
Size 160 Cartridge
MF P 160 AGE 10... 0160 MG 010 P
MF BN 160 AUE 3... 0160 MA 003 BN
MF BN 160 AUE 5... 0160 MA 005 BN
MF BN 160 AUE 10... 0160 MA 010 BN
MF BN 160 AUE 20... 0160 MA 020 BN
Size 180 Cartridge
MF BN 180 AUE 3... 0180 MA 003 BN
MF BN 180 AUE 5... 0180 MA 005 BN
MF BN 180 AUE 10... 0180 MA 010 BN
MF BN 180 AUE 20... 0180 MA 020 BN
Filter type MFD
Size 80 Cartridge
not available
not available
not available
Size 160 Cartridge
MFD P 160 AGF 10... 0160 MG 010 P
MFD BN 160 AUF 3... 0160 MA 003 BN
MFD BN 160 AUF 5... 0160 MA 005 BN
MFD BN 160 AUF 10... 0160 MA 010 BN
MFD BN 160 AUF 20... 0160 MA 020 BN
Size 180 Cartridge
MFD BN 180 AUF 3... 0180 MA 003 BN
MFD BN 180 AUF 5... 0180 MA 005 BN
MFD BN 180 AUF 10... 0180 MA 010 BN
MFD BN 180 AUF 20... 0180 MA 020 BN
2.6 CHANGING THE CARTRIDGE
Filter cartridge type MG:
Unscrew lter cartridge (using a strap
wrench, if necessary). Lubricate seal
on the new cartridge. Screw in new
cartridge until contact is made with the
sealing surface. Then hand-tighten.
Check for leakage and tighten further
if necessary.
Filter cartridge type MA:
Unscrew lter cartridge (using a strap
wrench, if necessary). Lubricate new
seal and insert it into the lter head.
Screw in new cartridge until contact is
made with the sealing surface. Then
hand-tighten. Check for leakage and
tighten further if necessary.
E 7.301.18/11.16
4
3. FILTER CALCULATION /
SIZING
The total pressure drop of a lter at a
certain ow rate Q is the sum of the
housing p and the element p and is
calculated as follows:
p
total
= p
housing
+ p
element
p
housing
= (see Point 3.1)
p
element
= Q
SK*
viscosity
1000 30
(*see Point 3.2)
For ease of calculation, our Filter
Sizing Program is available on request
free of charge.
NEW: Sizing online at www.hydac.com
3.1 p-Q HOUSING CURVES BASED
ON ISO 3968
The housing curves apply to mineral
oil with a density of 0.86 kg/dm³ and
a kinematic viscosity of 30 mm²/s.
In this case, the differential pressure
changes proportionally to the density.
3.2 GRADIENT COEFFICIENTS (SK) FOR FILTER ELEMENTS
The gradient coefcients in mbar/(l/min) apply to mineral oils with a kinematic
viscosity of 30 mm²/s. The pressure drop changes proportionally to the change in
viscosity.
MF 80
BN Filtration rating
3 µm 5 µm 10 µm 20 µm
80 4.3 2.5
160 4.3 3.6 2.0 1.1
180 2.2 1.9 1.1 0.6
p [bar]
Q [l/min]
MF 160, 180
p [bar]
Q [l/min]
MFD 160, 180
p [bar]
Q [l/min]
3.3 SIZING GUIDELINES
Filters should be calculated on the basis of a total differential pressure with clean
element and at operating temperature; for use as:
Suction lter: 0.03 - 0.05 bar
Return line lter: 0.3 - 0.5 bar
Pressure lter: 0.3 - 0.5 bar
However, cold start conditions must be taken into account.
5
E 7.301.18/11.16
4. DIMENSIONS
MF 80
MF 160/180
port for
clogging
indicator
type code 1
port for
clogging
indicator
type code 2
port for clogging
indicator
type code 1, 5 or 7
port for clogging
indicator
type code 2, 6 or 7
port for clogging
indicator
type code 3, 5 or 8
port for clogging
indicator
type code 4, 6 or 8
MA:
MA:
/ MG: 145
/ MG: 188
Ø
port for
clogging
indicator
type code 3
port for
clogging
indicator
type code 4
E 7.301.18/11.16
6
NOTE
The information in this brochure relates to the operating conditions and applications
described.
For applications or operating conditions not described, please contact the relevant
technical department.
Subject to technical modications.
HYDAC Filtertechnik GmbH
Industriegebiet
D-66280 Sulzbach/Saar
Tel.: 0 68 97 / 509-01
Fax: 0 68 97 / 509-300
Internet: www.hydac.com
E-Mail: lter@hydac.com
MFD 160/180
Summary
Filter type Port size Port size Weight incl. Vol. of pressure
Inlet / Outlet Cartridge element [kg] chamber [l]
MF 80 G¾, 1-12 UNF 0.9 1.00
MF 160 G1¼ G1¼, 1½x16 UN-2B 2.3 2.00
MF 180 G1¼ 1½x16 UN-2B 2.8 3.30
MFD 160 G1½ G1¼, 1½x16 UN-2B 3.7 4.00
MFD 180 G1½ 1½x16 UN-2B 4.5 6.60
port for
clogging
indicator
type code
1 or 5
port for
clogging
indicator
type code
3 or 5