X
-Series
Table of contents
Product features 2
General information and functional description 2
l Overview 2
Technical data 5
Modular structure 6
Example of valve specication and type code 8
Working sections 10
l Mono section M27 / M17 / M26P / M16P including single section type CS6 10
l Inlet section ML27 / ML17 / ML26P / ML16P including single section type CS6 12
l Single section B6 / CS6 / LS6 / LS6F 14
l End section SR16C / SR16 including single section type C6 or CS6 15
l Main spool and pressure compensator 16
l LS pressure limitation 19
l Workport valves 20
l Operation units 22
l Spring caps 23
l Optional ange blocks for single section type LS6F 24
Solenoid valves and coils 27
Connection type, fastening and tie rods 28
Installation, usage and maintenance information 28
Dimensions 29
Type code 32
Ordering examples 35
Nominal pressure: 350 bar
Maximum ow rate
l Pump port: 250 l/min
(180 l/min with pressure peak
protection unit)
l Working ports: 180 l/min
with compensator and load holding
function
Load-Sensing Sectional
Control Valve
LC
X
-6
EN 5.294.0 / 11.21
1
EN 5.294.0 / 11.21
2
A
T
T
P
B
2.7
2.1
2.4.1
2.4.2
2.4.42.4.32.3.22.3.1
Product features
The LCX-6 valve series is based on the existing LX-6 valve
series with the consistent focus on Closed center hydraulic
systems with variable displacement pumps and Compact
design in matter of space / weight reduction.
l Flow-optimized valve design
l High mechanical and electrical resolution
l Compact size and low weight
l Modular design up to 10 working sections
l Types of operation (with/without hand lever):
- Manual
- Hydraulic
- Electrohydraulic (on/off, proportional)
l Application-specic main spools with adjustable
stroke limiter
l Shock/anti-cavitation valves for protection
of actuators
Overview
2.7
Pressure compensator
2.1
Main spool
2.3.1
Workport valve port A (anti-cavitation valve)
2.3.2
Workport valve port B (shock / anti-cavitation valve)
2.4.1
Stroke limiter port A (clockwise rotation)
2.4.2
Stroke limiter port B (counterclockwise rotation)
2.4.3
Pressure control valve port A
2.4.4
Pressure control valve port B
l Adjustable load sense pressure limitation (mechanically
or electro proportionally) causes the compensator
to block ow to the working A or B
l Optional ange blocks for LS remote control of single sections
l Areas of application:
- Lifting platforms - Municipal vehicles - Cranes
- Drilling machinery - Truck applications - Forestry
- Construction - Stationary applications - Agricultural
!
The individual single sections of the LX-6 valve series are
used 1:1 in the LCX-6 valve series and are therefore inter-
changeable. The inlet and end modules cannot be combined
or exchanged between the two valve series.
The existing LX-6 product range continues to offer the necessary
and increased exibility for extended functional scopes (e. g.
3-way ow controller for hydraulic systems with xed displace-
ment pumps) – HYDAC product specication EN 5.282.
The LCX-6 is a pre compensated proportional directional
control valve according to the load-sensing principle.
The nominal ow rate to the working ports A and B is 160 l/min.
The main spool
2.1
determines the ow direction and
magnitude of ow rate.
Pressure control valves
2.4.3
and
2.4.4
are providing shifting
pressure to the left and right side of the main spool
2.1
to
control its position. The level of electric current determines
the level of the pilot pressure and therefore the position of
the main spool.
Adjustable stroke limiters
2.4.1
and
2.4.2
can be set mechanically
to limit the maximum ow rate to the working ports A and B.
The pressure compensator
2.7
keeps the ow rate to
the actuator constant, even if the system pressure varies.
Pressure changes at the pump or working ports A and B
are compensated for each working section individually.
The maximum operating pressure can be adjusted by
LS pressure limitation for working ports A and B separately.
Shock / anti-cavitation valves
2.3.2
protect the working
ports A and B from pressure peaks. Anti-cavitation valves
2.3.1
protect the system from cavitation.
Shuttle valves are integrated into the working sections
to report the highest load pressure for the valve stack
to the inlet section or variable displacement pump.
General information and functional description
EN 5.294.0 / 11.21
3
Overview
Ports
P Pump
MP Pump measuring port
T Tank
LS Load-sensing
A, B Working ports
C Pilot oil supply
Z Pilot drain
(must always be connected / depressurized to tank)
MY Pilot pressure measuring port (port B)
1.0
Mono section
1.1
Filter unit
1.2
Pressure reducing valve for internal pilot oil supply
2.1
Main spool
2.2.3
LS pressure limitation port A / B combined
2.3.1
Workport valve port A
2.3.2
Workport valve port B
2.4
Operation unit
2.4.1
Stroke limiter of main spool port A
2.4.2
Stroke limiter of main spool port B
2.5
Spring cap
2.7
Pressure compensator
2.3.2
1.2
2.5
2.3.1
2.2.3
2.4
1.0
2.4.22.4.1
BA
B
A
P
T
MP
LS
C
Z
A/B
MY
1.0 1.2
2.5 2.1
2.2.3 2.4
2.3.1
2.3.2
2.7
1.1
EN 5.294.0 / 11.21
4
Overview
1.0
Inlet section
1.1
Filter unit
1.2
Pressure reducing valve for internal pilot oil supply
2.0
Single section
2.1
Main spool
2.2.1
LS pressure limitation port A
2.2.2
LS pressure limitation port B
2.2.3
LS pressure limitation port A / B combined
2.3.1
Workport valve port A
2.3.2
Workport valve port B
2.4
Operation unit
2.4.1
Stroke limiter of main spool port A
2.4.2
Stroke limiter of main spool port B
2.5
Spring cap
2.6
Optional ange block for working section
2.7
Pressure compensator
2.8
LS shuttle valve
3.0
End section
Ports
P Pump
MP Pump measuring port
T Tank
LS Load-sensing for complete valve
LR Load-sensing resultant (sectional port A and B)
A, B Working ports
X, Y Hydraulic operation ports (Main spool position a / b)
C Pilot oil supply
Z Pilot drain
(must always be connected / depressurized to tank)
MX Pilot pressure measuring port (port A)
MY Pilot pressure measuring port (port B)
1.0 2.0
2.4.22.4.1
2.5
2.3.2
2.3.1
2.2.2
2.4
2.2.1
2.2.3
1.1
2.5 2.1 2.3.12.7 2.8
2.6
2.3.2
1.0
2.2.2
1.2 2.0
3.02.2.1 2.2.32.4
3.0
2.2.3
1.2
2.6
EN 5.294.0 / 11.21
5
Technical data
General data and operating conditions
No. of working sections: 1 10
Installation position: Preferred horizontal to the main spool axis or vertical
with the operation unit to the top (spring cap to the bottom)
Mass in kg: Mono section M...7-CS6 / M...6P-CS6
Inlet section ML...7-CS6 / ML...6P-CS6
Single section B6 / CS6 / LS6 / LS6F
End section SR16...-C6 / SR16...-CS6
8.3 / 8.1
7.8 / 7.6
5.1 / 4.9 / 4.7 / 4.6
5.5 / 5.3
Operation unit MHS / HHS / EYHS / ES
Hand lever 1 / 2 / 3
Optional ange block LD1 / LW... / LW1...
0.3 / 0.4 / 0.7 / 0.6
0.1
0.3 / 1.2 / 1.6
Tie rod for working sections 2 / 4 / 6 / 8 / 10 0.3 / 0.5 / 0.7 / 0.9 / 1.1
Connection type (thread type): BSPP acc. to ISO 1179-1 (SAE on inquiry only)
Ambient temperature range: -20 to + 60 °C
1)
Hydraulic uid temperature range: -20 to + 80 °C
1)
Painting: Standard primer and top coat RAL 9005 on inquiry
Hydraulic data
Maximum ow rate P / A, B 250 l/min P port size 7 (180 l/min P port size 6) / 180 l/min
Nominal pressure 350 bar
Max. operating
pressure at port:
P / A, B 350 bar / 420 bar
T 30 bar
Z
Drained to tank
!
must always be connected / depressurized to tank
Max. pilot pressure at port C / X, Y 30 bar
Pilot pressure range 6.5 to 20 bar hydraulic
4.5 to 20 bar electrohydraulic
Required control Δp at the control block 17 bar
Hydraulic uid Mineral oil (HL/HLP) acc. to DIN 51524, other hydraulic uids on inquiry
Viscosity range 10 – 400 mm
2
/s
Max. permitted degree of contamination
of the hydraulic uid
20/18/15 acc. to ISO 4406 (c)
Please contact HYDAC Filtration Technology to ensure system cleanliness
Electrical data
Supply voltages 12 V DC / 24 V DC
Solenoid data See chapter “Operation units” and “Solenoid valves and coils”
Connector type and IP protection class
(with mating connector mounted and locked)
AMP Junior Timer, 2-pin, axial / up to IP6K6
2)
Deutsch DT04, 2-pin, axial / up to IPX9K
2)
Ampliers and control devices See Product Catalogue 18.500 – Control Technology for Mobile Machines
1)
Deviation of data on inquiry only
2)
Mating plug-in connectors are not included
!
The technical data and characteristic curves were determined at a viscosity of 32 mm²/s
EN 5.294.0 / 11.21
6
Modular structure
If only one hydraulic function is needed, the LCX-601 is the right choice.
It consists of one mono section which does not require separate inlet and end plates – everything is included.
It can be customised to different applications and machines.
Type code structure
General LCX-601 / B 0
Connection type B (BSPP)
Mono section M27 1.1
Mono section M27-CS6, M17-CS6 , M26P-CS6, M16P-CS6
CS6 / ... 2.5
Manual operation MHS
2.6
Hydraulic operation HHS
2.7
Electrohydraulic operation EYHS, E1YHS, ES, E1S
2.8
Spring cap C1..., C1X ...
Setup with mono section
1.1
2.8
2.5
2.6
2.7
EN 5.294.0 / 11.21
7
Setup with left hand inlet section
Type code structure
General LCX-6 _ _ / B 0
Connection type B (BSPP)
No. of working sections (02 - 10)
Inlet section ML27 1.1
Inlet section ML27-CS6, ML17-CS6, ML26P /...-CS6, ML16P /...-CS6
CS6 / ...
Single sections LS6F / ... / LW... 2.1
Single section B6
B6 / ... 2.2
Single section CS6
. 2.3
Single section LS6
. 2.4
Single section LS6F
. 2.5
Manual operation MHS
. 2.6
Hydraulic operation HHS
. 2.7
Electrohydraulic operation EYHS, E1YHS, ES, E1S
. 2.8
Spring cap C1..., C1X ...
LS6 / ... 2.9
Optional ange block LD1, LW ..., LW1 ...
End section SR16C 3.1
End section SR16C-C6, SR16-C6
CS6 / ... 3.2
End section SR16C-CS6, SR16-CS6
1.1
3.2
3.1
2.1
2.2
2.3
2.8
2.5
2.6
2.92.7
2.4
Modular structure
If two or more hydraulic functions are needed, the LCX-6 valve series provides a modular structure.
It consists of an inlet and outlet section with integrated working function and can be combined
with further single sections from the LX-6 valve series (LCX-602 up to LCX-610).
EN 5.294.0 / 11.21
8
Example of valve specications and type code
Example: mono section control valve for hydraulic system with variable displacement pump (CC system)
Type code Control valve specication
Valve type LCX-601
LCX-6 with 1 working section
LCX-601 / B0 B0
BSPP connection type, valve series 0
Mono section / valve
M27
M27
Mono section for CC systems with internal pilot oil supply,
port C with plug screw
CS6
/
CS160-160RN
/
250
/
300-300
/
EYHS2D-1
/
C1E
CS6
Section type with combined LS and workport valves
CS-RN
- Main spool type CS (closed in neutral position)
- Flow rate at working port A and B 160 l/min
- Pressure compensator with load holding function,
spring type N
250
LS pressure limitation port A / B 250 bar
300 – 300
Shock valve port A 300 bar, port B 300 bar
EYHS2D-1
- Electrohydraulic operation and measuring port MY
- Hand lever axis and stroke limiter
- 24 V solenoid and connector type Deutsch DT04-2P
- Hand lever type 1
C1E
Spring cap for electrohydraulic operation
Example: sectional control valve for hydraulic system with variable displacement pump (CC system)
Type code Control valve specication
Valve type LCX-603
LCX-6 with 3 working sections
LCX-603 / B0 B0
BSPP connection type, valve series 0
Inlet section
ML27
ML27
Left hand inlet section for CC systems,
with internal pilot oil supply
CS6
/
CS160-160RN
/
250
/
300-300
/
EYHS2D-1
/
C1E
CS6
Section type with combined LS and workport valves
CS-RN
- Main spool type CS (closed in neutral position)
- Flow rate at working port A and B 160 l/min
- Pressure compensator with load holding function,
spring type N
BA
B
A
P
T
MP
LS
C
Z
A/B
MY
EN 5.294.0 / 11.21
9
Example of valve specications and type code
Single section
LS6 / CS050-050RG / P-200 / P-230 / EYHS2D-1 / C1E
LS6
Single section with LS and workport valves
CS-RG
- Main spool type CS (closed in neutral position)
- Flow rate at working port A and B 50 l/min
- Pressure compensator with load holding function,
spring type G
P-200
LS pressure limitation port A plug screw, port B 200 bar
P-230
Shock valve port A plug screw, port B 230 bar
EYHS2D-1
- Electrohydraulic operation and measuring port MY
- Hand lever axis and stroke limiter
- 24 V solenoid and connector type Deutsch DT04-2P
- Hand lever type 1
C1E
Spring cap for electrohydraulic operation
End section
SR16C SR16C
Right hand end section, port C with plug screw
CS6 / CS030-030RG / 130 / 160-160 / EYHS2D-1 / C1E
CS6
Section type with combined LS and workport valves
CS-RG
- Main spool type CS (closed in neutral position)
- Flow rate at working port A and B 30 l/min
- Pressure compensator with load holding function,
spring type G
130
LS pressure limitation port A / B 130 bar
160 – 160
Shock valve port A 160 bar, port B 160 bar
EYHS2D-1
- Electrohydraulic operation and measuring port MY
- Hand lever axis and stroke limiter
- 24 V solenoid and connector type Deutsch DT04-2P
- Hand lever type 1
C1E
Spring cap for electrohydraulic operation
BA
B
A
C
Z
C
P
T
LX
LS
BA
B
A
A
B
BA
B
A
P
T
MP
LS
Z
T
Z
C
P
LX
LS
MY
MY MY
A/BA/B
Type code Control valve specication
250
LS pressure limitation port A / B 250 bar
300 – 300
Shock valve port A 300 bar, port B 300 bar
EYHS2D-1
- Electrohydraulic operation and measuring port MY
- Hand lever axis and stroke limiter
- 24 V solenoid and connector type Deutsch DT04-2P
- Hand lever type 1
C1E
Spring cap for electrohydraulic operation
EN 5.294.0 / 11.21
10
M27
CS6 / ...
Mono section M27 / M17 including single section type CS6
Type code
M27 - CS6
M17 - CS6
1 2
M17
CS6 / ...
1
Basic type
M
Mono section for CC systems
2 or 1
2: Internal pilot oil supply, port C plugged
1: External pilot oil supply, port C open
7
Port size P/T
!
Max. ow rate pump port P: 180 l/min
2
Section type
CS6
Section type with combined LS pressure limitation
and workport valves
M27
CS6/...
M26P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
BA
B
A
P
T
MP
LS
Z
C
(0)
(a)
(b)
M17
CS6/...
M16P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
A/B
BA
B
A
P
T
MP
LS
Z
A/B
C
(0)
(a)
(b)
A/B
A/B
M27
CS6/...
M26P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
BA
B
A
P
T
MP
LS
Z
C
(0)
(a)
(b)
M17
CS6/...
M16P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
A/B
BA
B
A
P
T
MP
LS
Z
A/B
C
(0)
(a)
(b)
A/B
A/B
Internal pilot oil supply,
port C plugged
External pilot oil supply,
port C open
EN 5.294.0 / 11.21
11
Characteristic curves (measured at 32 mm²/s)
Mono section M26P / M16P including single section type CS6
p in bar
Q in l/min
Pressure relief function P → T
0 20 40 60 80 100 120 140 160 180 200
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
Type code
M26P / 250 - CS6
M16P / 300 - CS6
1
Basic type
M Mono section for CC systems
2 or 1
2: Internal pilot oil supply, port C plugged
1: External pilot oil supply, port C open
6 Port size P (port size T : 7)
P Pressure peak protection unit
!
Max. ow rate pump port P: 180 l/min
2
Pressure peak protection setting
_ _ _ Pressure setting in bar, 3-digit (xed)
Possible settings:
200, 210, 230, 240, 250, 265, 280, 300, 320
!
Preparation of 2 shock/ anti-cavitation valves
(same setting) for pressure peak protection
and anti-cavitation prevention only.
The setting has to be min. 30 bar higher than
the LS pressure limitation setting in the working
sections and other relevant devices of the
complete hydraulic system.
!
The setting for shock/anti-cavitation valves
are xed and dened at a ow rate of 10 l/min.
1)
3
Section type
CS6
Section type with combined LS pressure limitation
and workport valves
1 2 3
M26P /
_ _ _
CS6 / ...
M16P /
_ _ _
CS6 / ...
1)
See chapter “Workport valves”
M27
CS6/...
M26P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
BA
B
A
P
T
MP
LS
Z
C
(0)
(a)
(b)
M17
CS6/...
M16P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
A/B
BA
B
A
P
T
MP
LS
Z
A/B
C
(0)
(a)
(b)
A/B
A/B
M27
CS6/...
M26P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
BA
B
A
P
T
MP
LS
Z
C
(0)
(a)
(b)
M17
CS6/...
M16P/ _ _ _
CS6/...
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
C
Z
A/B
BA
B
A
P
T
MP
LS
Z
A/B
C
(0)
(a)
(b)
A/B
A/B
Internal pilot oil supply,
port C plugged
External pilot oil supply,
port C open
2
2
EN 5.294.0 / 11.21
12
Inlet section ML27 / ML17 including single section type CS6
Type code
ML27 - CS6
ML17 - CS6
ML27
CS6 / ...
1
Basic type
M
Multi inlet section for CC systems
L Left hand side
2 or 1
2: Internal pilot oil supply
1: External pilot oil supply
7 Port size P/T
!
Max. ow rate pump port P: 250 l/min
2
Section type
CS6
Section type with combined LS pressure limitation
and workport valves
ML27
CS6/…
ML26P/ _ _ _
CS6/…
ML17
CS6/…
ML16P/ _ _ _
CS6/…
BA
B
A
P
T
MP
LS
Z
T
Z
C
P
LX
LS
A/B
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
Z
T
Z
C
P
LX
LS
A/B
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
Z
A/B
T
Z
C
P
LX
LS
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
Z
A/B
T
Z
C
P
LX
LS
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
Z
T
Z
C
P
LX
LS
A/B
(0)
(a)
(b)
ML17
CS6 / ...
1 2
Internal pilot
oil supply
External pilot
oil supply
EN 5.294.0 / 11.21
13
ML26P/ _ _ _
CS6/…
ML16P/ _ _ _
CS6/…
BA
B
A
P
T
MP
LS
Z
Z
C
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
Z
A/B
T
Z
C
P
LX
LS
(0)
(a)
(b)
A/B
T
P
LX
LS
ML26P/ _ _ _
CS6/…
ML16P/ _ _ _
CS6/…
BA
B
A
P
T
MP
LS
Z
Z
C
(0)
(a)
(b)
BA
B
A
P
T
MP
LS
Z
A/B
T
Z
C
P
LX
LS
(0)
(a)
(b)
A/B
T
P
LX
LS
Characteristic curves (measured at 32 mm²/s)
p in bar
Q in l/min
Pressure relief function P → T
0 20 40 60 80 100 120 140 160 180 200
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
Inlet section ML26P / ML16P including single section type CS6
Type code
ML26P / 250 - CS6
ML16P / 300 - CS6
1 2 3
ML26P /
_ _ _
CS6 / ...
ML16P /
_ _ _
CS6 / ...
1
Basic type
M Multi inlet for CC systems
L Left hand side
2 or 1
2: Internal pilot oil supply
1: External pilot oil supply
6 Port size P (port size T : 7)
P Pressure peak protection unit
!
Max. ow rate pump port P: 180 l/min
2
Pressure peak protection setting
_ _ _ Pressure setting in bar, 3-digit (xed)
Possible settings:
200, 210, 230, 240, 250, 265, 280, 300, 320
!
Preparation of 2 shock/ anti-cavitation valves
(same setting) for pressure peak protection
and anti-cavitation prevention only.
The setting has to be min. 30 bar higher than
the LS pressure limitation setting in the working
sections and other relevant devices of the
complete hydraulic system.
!
The setting for shock/anti-cavitation valves
are xed and dened at a ow rate of 10 l/min.
1)
3
Section type
CS6
Section type with combined LS pressure limitation
and workport valves
1)
See chapter “Workport valves”
External pilot
oil supply
Internal pilot
oil supply
2
2
EN 5.294.0 / 11.21
14
B6/…
Z
C
P
T
LX
LS
BA
Z
C
P
T
LX
LS
LS6/…CS6/…
Z
C
P
T
LX
LS
BA
B
A
A/B
BA
B
A
A
B
Z
C
P
T
LX
LS
LS6F/…
T LA LB LR LS
BA
B
A
A
B
(0)
(a)
(b)
(0)
(a)
(b)
(0)
(a)
(b)
(0)
(a)
(b)
B6 / ... LS6 / ...CS6 / ... LS6F / ...
Single section B6 / CS6 / LS6 / LS6F
Flange channels
Z Pilot drain
LA Load signal port A
LB Load signal port B
LR Load signal port A and B
LS Load-Sensing
(LS circuit)
1
Type code
B6 / CR160 - 160RN / EYHS2D-1 / C1E
CS6 / CR160 - 160RN / 250 / 300 – P / EYHS2D-1 / C1E
LS6 / CR160 - 160RN / 250 – P / 300 – P / EYHS2D-1 / C1E
LS6F / CR160 - 160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
21 3 4 5 6 7
1
Basic type
B6
Basic section type w/o LS pressure limitation
and workport valves
CS6
Section type with combined LS pressure limitation
and worport valves
LS6
Section type with LS pressure limitation
and workport valves
LS6F
Section type with LS pressure limitation
and workport valves
Flange interface for optional ange blocks
Port size 6 for working ports A / B
2
Main spool and pressure compensator
3
LS pressure limitation
4
Workport valves
5
Operation unit
6
Spring cap
7
Optional ange blocks for basic type LS6F
5
2
3
4
6 7
1
EN 5.294.0 / 11.21
15
End section SR16C / SR16 including single section type C6 or CS6
1 2
Type code
SR16C - C6 (CS6)
SR16 - C6 (CS6)
1 2
SR16C
C6 / ...
SR16
C6 / ...
SR16C
C6/…
SR16C
CS6/…
BA
C
Z
C
P
T
LX
LS
A/B
(0)
(a)
(b)
BA
B
A
C
Z
C
P
T
LX
LS
(0)
(a)
(b)
SR16
C6/…
SR16
CS6/…
BA
C
Z
C
P
T
LX
LS
(0)
(a)
(b)
BA
B
A
A/B
C
Z
C
P
T
LX
LS
(0)
(a)
(b)
A/B
A/B
SR16C
C6/…
SR16C
CS6/…
BA
C
Z
C
P
T
LX
LS
A/B
(0)
(a)
(b)
BA
B
A
C
Z
C
P
T
LX
LS
(0)
(a)
(b)
SR16
C6/…
SR16
CS6/…
BA
C
Z
C
P
T
LX
LS
(0)
(a)
(b)
BA
B
A
A/B
C
Z
C
P
T
LX
LS
(0)
(a)
(b)
A/B
A/B
1
Basic type
SR Section right hand side (end section)
1 Version
6 Port size A / B
C
Port C with plug screw,
for internal pilot oil supply in inlet section
1)
(if no letter C in type code, port C open
for external pilot oil supply)
2
Section type
C6
Section type with combined LS pressure limitation
and w/o workport valves
CS6
Section type with combined LS pressure limitation
and workport valves
1)
See chapter “Inlet section”
SR16C
CS6 / ...
SR16
CS6 / ...
EN 5.294.0 / 11.21
16
Main spool and pressure compensator
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
Examples
CR 160 - 160 R N
MS 180 - 180 L
2.1 Basic type of main spool
2.2 Max. ow at port A to actuator in l/min
2.3 Characteristic curve and overlap
2.4 Max. ow at port B to actuator in l/min
2.5 Basic type of pressure compensator / load holding function
2.6 Pressure compensator spring type
Cylinder as actuator
CS 4/3 directional valve closed in neutral position
CR 4/3 directional valve unloaded in neutral position
CT
4/3 directional valve closed in neutral position
20 bar return orice for A and B → T
to support system stability
CC
4/3 directional valve unloaded in neutral position
20 bar return line orice for port A and B → T
to support system stability
Motor as actuator
MS 4/3 directional valve open in neutral position
Characteristic curves (measured at 32 mm²/s)
p in bar
CS
MS
Q (A/B) in l/min
Differential pressure A/B → T
0 20 40 60 80 100 120 140 160 180 200
8
6
4
2
0
CS: Cylinder spool type – nominal control edge size: 08
MS: Motor spool type – nominal control edge size: 08
2.1 2.2 2.42.3 2.5 2.6
Basic type of main spool
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
CS CR CT CC
(b)
(0)
(a)
P
T
A
B
MS
(b)
(0)
(a)
!
Other spool types and congurations on inquiry
EN 5.294.0 / 11.21
17
Symmetrical spools
Max. ow rate to actuator in l/min (Port A - Port B) Pressure
compensator
Pressure com-
pensator spring
Type Type Identier
180 - 180 150 - 150 125 - 125 090 - 090 062 - 062 045 - 045 030 - 030 020 - 020 R Y Yellow
170 - 170 138 - 138 116 - 116 085 - 085 058 - 058 042 - 042 028 - 028 019 - 019 R B Blue
160 - 160 130 - 130 110 - 110 080 - 080 055 - 055 040 - 040 027 - 027 018 - 018 010 - 010 R N None
100 - 100 072 - 072 050 - 050 036 - 036 025 - 025 016 - 016 R G Green
Nominal control edge size
08 - 08 07 - 07 06 - 06 05 - 05 04 - 04 03 - 03 02 - 02 01 - 01 00 - 00
Asymmetrical spools
Nominal control edge size
08 - 06 07 - 05 06 - 04 05 - 03 04 - 02 03 - 02 02 - 01 01 - 00
08 - 05
Main spool and pressure compensator
Type code
CR 160 - 160 R N
2.1 2.2
2.2
2.3 2.4
2.4
2.5
2.5
2.6
2.6
Main spool ow range
Characteristic curves for nominal ow rates of main spool (measured at 32 mm²/s)
Example:
Max. ow to the actuator at working port A and B: 120 l/min
1. See table above: nominal control edge size 06 – 06 with pressure compensator spring YQ
max
= 125 - 125 l/min
2. Setting to nal target value 120 l/min by stroke limiter
Q (A/B) in l/min
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
08
07
06
05
04
03
02
01
12 V: l in mA
24 V: l in mA
Hydraulic in bar
Stroke in mm
500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500
250 300 350 400 450 500 550 600 650 700 750
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
!
Place working sections
(machine functions) with
maximum ow as close
as possible to inlet section
(port P and T).
EN 5.294.0 / 11.21
18
Flow control by section pressure compensator
Main spool and pressure compensator
Type code
CR 160 - 160 R N
2.1 2.2 2.3 2.4 2.5 2.6
A A
T TT T
P P
B B
2.12.6 2.5
Main spool in neutral position
(Type CR – A/B unloaded to T)
Main spool out of neutral position
(P → B, A → T)
P is not connected to the working ports A and B when the main spool
2.1
is in neutral position(Fig. A). The compensator spool
2.5
is moved to left against the compensator spring
2.6
by pump pressure and blocks ow to the main spool.
When the main spool
2.1
is operated out of the neutral position (Fig. B), the load pressure (LS pressure) of the working port A or B
is connected to the spring chamber of the pressure compensator and moves the compensator spool to the right into a corresponding
controlled position.
The ow rate through the main spool (= metering orice) is kept constant by the pressure compensator when sections are in parallel
operation with different load or pump pressures.
The characteristic ow rate curve of a main spool can be adapted and optimized to each application by using the different pressure
compensator spring types Y, B, N or G.
Basic types of pressure compensator / load holding function
R Pressure compensator spool - released
with load holding function (standard type)
!
The load holding function is not
free of leak oil, the hydraulic
schematic / symbol is simplied
The pressure compensator R must always be
indicated in the type code with the corresponding
compensator spring type Y, B, N or G.
L
Load holding function only
!
The load holding function is not free of
leak oil, the hydraulic schematic / symbol
is simplied.
Different load or pump pressures are not
compensated when sections are in parallel operation.
The ow rate to the actuator depends on the pressure
difference between pump pressure and load (LS pressure).
Main spool denition and detailed system setup on inquiry.
The pressure compensator spring
2.6
is not indicated
for the load holding function in the type code.
Example: MS180-180L
Pump pressure compensation (measured at 32 mm²/s)
Figure A Figure B
Q (A/B) in l/min
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 40 80 120 160 200 240 280 320 360
p (P - A/B) in bar
LS6F / CR160 - 160RN / 250 – P / 300 – P / EYHS2D - 1 / C1E / LWRV2D
EN 5.294.0 / 11.21
19
BA
B
A
A
B
MY
Z
C
P
T
LX
LS
LS pressure limitation
Type code
250 – P
3.1 3.2
Adjustable LS pressure limitation by blocking the sectional ow
rate to the working ports A and B.
For LS option valves and electro-proportional pressure adjustment,
see chapter “Optional flange blocks for working section LS6F”.
3.1
3.2
Basic type
_ _ _
Pressure setting in bar, 3-digit
Minimum setting: 050 bar
Maximum setting: 320 bar
P Plug screw
3.1 LS pressure limitation port A
3.2 LS pressure limitation port B
Load pressure compensation / limitation
(measured at 32 mm²/s)
p (A/B) in bar
Q (A/B) in l/min
0 40 80 120 160 200 240 280 320 360
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
!
The optional pressure peak protection setting in the inlet
section has to be min. 30 bar higher than the LS pressure
limitation setting in the working sections and other relevant
devices of the complete hydraulic system.
!
Min. / Max. LS pressure limitation setting: 050 / 320 bar
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
EN 5.294.0 / 11.21
20
BA
B
A
A
B
MY
Z
C
P
T
LX
LS
Workport valves
Type code
300 – P
4.1 4.2
Basic type
_ _ _
Shock/ anti-cavitation valve
Pressure setting in bar, 3-digit (xed)
See table on next page for settings
A
Anti-cavitation valve
P
Plug screw
4.1 Workport valve port A
4.2 Workport valve port B
Fixed shock/anti-cavitation valves protect working ports A and
B against pressure peaks and cavitation. Anti-cavitation valves
protect the system against cavitation.
!
Shock/anti-cavitation valves are only for reduction of pressure
peaks and should not be used as pressure relief valves.
!
The settings for shock/anti-cavitation valves are xed ex works.
The pressure setting is dened at a ow rate of 10 l/min.
Characteristic curves (measured at 32 mm²/s)
p (A/B) in bar
Q (A/B) in l/min
Shock function A/B → T
0 10 20 30 40 50 60 70 80
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
4.1
4.2
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
EN 5.294.0 / 11.21
21
Workport valves
Shock / anti-cavitation valve pressure settings (xed)
Settings bar 050 065 080 100 125 140 150 160 175 190 200 210 230 240 250 265 280 300 310 320 350 380
Tolerance range ± bar 5 5 5 5 7 7 7 7 10 10 10 10 10 10 10 12 12 12 12 12 12 15
Max. LS pressure cut-off bar - 050 060 080 105 120 120 130 145 160 170 180 200 210 220 235 250 270 280 290 320 320
!
Min. / Max. LS pressure limitation setting: 050 / 320 bar
Characteristic curves (measured at 32 mm²/s)
!
The maximum pressure setting for the shock/anti-cavitation
valves depends on the chosen pressure settings for the LS
limitations port A and B. To avoid interaction recommended
values are shown in the following table.
The values listed in the table are calculated according
to the following guidelines:
Shock valve setting p
shock
< 150 bar: p
shock
– p
LS
> 20 bar
Shock valve setting p
shock
150 bar: p
shock
– p
LS
> 30 bar
Operation units
Type code
E Y H S 2D - 1
H S
5.1 5.2 5.3
5.1 Basic type
5.2 Electrical supply voltage, connector type
5.3 Hand lever
S: Shock/ anti-cavitation valve
A: Anti-cavitation valve
Anti-cavitation function TA/B
p in bar
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
15
10
5
0
Q (A/B) in l/min
A
S
LS6F / CR160 - 160RN / 250 – P / 300 – P / EYHS2D - 1 / C1E / LWRV2D
MHS
Unit for manual operation
Hand lever axis and spool stroke limiter
HHS
Unit for hydraulic operation
Hand lever axis and spool stroke limiter
Port X: spool position (a)
Port Y: spool position (b)
EYHS
Unit for electrohydraulic operation proportional
Pilot pressure measuring port MY: spool position (b)
Hand lever axis and spool stroke limiter
E1YHS
Unit for electrohydraulic operation proportional
Dampening orice with diameter 1 mm
Pilot pressure measuring port MY: spool position (b)
Hand lever axis and spool stroke limiter
ES
Unit for electrohydraulic operation proportional
Spool stroke limiter
E1S
Unit for electrohydraulic operation proportional
Dampening orice with diameter 1 mm
Spool stroke limiter
!
Dampened E1 ... units have to be used
for pure on / off actuations
!
For all operation unit types port Z must
always be connected / depressurized to tank
MHS
HHS EYHS
E1YHS
ES
E1S
(0)
(a)
(b)
(0)
(a)
(b)
MY
(0)
(a)
(b)
YX
(0)
(a)
(b)
(0)
(a)
(b)
Basic types 5.1
MHS HHS EYHS
E1YHS
ES
E1S
EN 5.294.0 / 11.21
22
Operation units
General
Supply voltage V DC 12 24
Coil resistance
at 20 °C (±5%)
Ω 4.7 20.8
Duty cycle % 100
Connector type and IP protection class
(with mating connector mounted and locked)
AMP Junior Timer,
2-pin, axial
up to IP6K6
2)
Deutsch DT04,
2-pin, axial
up to IPX9K
2)
Protective screen µm 125
- w/o hand lever (n/a)
1 Standard lever
2 Standard lever, short for emergency operation
3 Universal clamp without hand lever
3_ Universal clamp with hand lever (standard length)
Interface of hand lever axis and hand lever:
Hexagon WAF9
!
The hand lever is directly connected to the main spool
and follows the movement of the spool.
A hand lever can only be specied in combination
with a hand lever axis type H
5.1
.
Hand lever 5.3
Electrical supply voltage, connector type 5.2
1_ 12 V
2_ 24 V
_A AMP Junior Timer
_D Deutsch DT04-2P
!
Electrohydraulic operation can be overrided by
mechanical operation .
The hand lever is directly connected to the main spool
and follows the movement of the spool.
( 0)
( a)
( b)
1 / 2 / 3 / 3_
Technical data for electrohydraulic pilot valves (on/off and proportional)
Pressure control valve (proportional)
Supply voltage V DC 12 24
Max. control current mA 1,500 750
PWM frequency
(recommended)
1)
Hz 100 ... 150
1)
The PWM frequency is to be optimized depending
on the application
2)
Mating plug-in connectors are not included
!
Standards ISO 13732-1 and ISO 4413 must be observed
in regard to the surface temperatures occurring on the coils.
ca. 30°
19.5°
ca. 30°
Port A
Port B
EN 5.294.0 / 11.21
23
Operation units
Spring caps
Standard lever Standard lever, short
(Emergency operation)
Universal clamp
Universal clamp
with hand lever
1 2
31 32
3_
33
3
Left
3x M8x1.25 / 8 deep
Top Right
200
93
57
57
57
214
169.5169.5
Ø 25
Possible hand lever positions: see chapter “Dimensions”
Actuation torques: - Manual: min. 2.5 – 4 Nm
- Hydraulic: min. 5 – 19 Nm
- Electrohydraulic: min. 3 – 19 Nm
Type code
LS6F / CR160 - 160RN / 250 – P / 300 – P / EYHS2D - 1 / C1E / LWRV2D
C1 E
6.1 6.2
6.1
Basic type
C1 Type 1 (standard)
C1X
Type 1 (standard)
Pilot pressure measuring port MX: spool position (a)
6.2
Main spool spring package
!
The spring package must be specied
according to the operation unit
5.1
.
M Manual operation type MHS
H Hydraulic operation type HHS
E
Electrohydraulic operation type
EYHS, E1YHS, ES, E1S
C1_ C1X_
(0)
(a)
(b)
MX
(0)
(a)
(b)
C1 _ C1X _
EN 5.294.0 / 11.21
24
Optional ange blocks for single section type LS6F
T LA LB LR LS
Type code
LW R V 2D
7.1 7.2 7.3 7.4
Dummy plate
LD Basic type
1 Version 1
LS option valves
1)
!
Unloading the load signal or LS circuit with
the option valves V and W will not block the ow
to the working ports A and B completely
when the main spool is out of neutral position.
Regardless of viscosity or parallel operation,
the working pressure during blocking can be up
to 15 bar depending on the selected pressure
compensator spring type.
7.1
Basic type LW
7.2
Flange channel
A Load signal port A
B Load signal port B
R Load signal port A and B
S Load-Sensing (LS circuit)
7.3
Solenoid valve
V
LS unloading
Normally open (Manual
emergency operation)
W
LS unloading
Normally closed (Manual
emergency operation)
P0A
Electro-proportional
pressure adjustment
Pressure stage A: 350 bar
12 V: I
max
= 1,500 mA
24 V: I
max
= 750 mA
!
The electro-proportional pressure relief valve P0A
is not suitable for acting as an unloading valve
1)
7.4
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
1)
See chapter Solenoid valves and coils
LD1
Flange channels
T Tank
LA Load signal port A
LB Load signal port B
LR Load signal port A and B
LS Load-Sensing
(LS circuit)
T LA LB LR LS
7.2 7.1
7.37.4
!
The LS optional ange blocks can be used
only in combination with the sectional pressure
compensator type R
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
Z
C
P
T
LX
LS
BA
B
A
MY
A
B
T LA LB LR LS
EN 5.294.0 / 11.21
25
Example congurations
LWRV2A
l Basic type LW
l Load signal port A and B
l LS option valve type V, normally open
l 24 V solenoid and connector type AMP Junior Timer
LWRP0A1D
l Basic type LW
l Load signal port A and B
l LS option valve type P0A, electro-proportional
pressure adjustment (pressure stage A: 350 bar)
l 12 V solenoid and connector type Deutsch DT04-2P
T LA LB LR LS
T LA LB LR LS
T LA LB LR LS
T LA LB LR LS
T LA LB LR LS
T LA LB LR LS
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LW1V-V2D
7.1
Basic type LW1
7.2
Solenoid valve for load signal port A
7.3
Solenoid valve for load signal port B
V
LS unloading
Normally open (Manual
emergency operation)
W
LS unloading
Normally closed (Manual
emergency operation)
7.4
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
LW1 V - V_ _
LW1 W - V_ _
LW1 V - W_ _
LW1 W - W_ _
LWRV2A LWRP0A1D
Optional ange blocks for single section type LS6F
!
The LS optional ange blocks can be used
only in combination with the sectional pressure
compensator type R
LW1 V - V 2D
7.1 7.2 7.3 7.4
EN 5.294.0 / 11.21
26
T LA LB LR LS
T LA LB LR LS
T LA LB LR LS
Optional ange blocks for single section type LS6F
Type code
LW R M_ _ _ -V 2D
7.1 7.2 7.3 7.4 7.5
Switchable LS pressure limitation (2. pressure stage)
1)
7.1
Basic type LWM
7.2
Flange channel
A Load signal port A
B Load signal port B
R Load signal port A and B
S Load-Sensing (LS circuit)
7.3
LS pressure limitation
_ _ _ LS pressure setting in bar, 3-digit
Minimum setting: 050 bar
Maximum setting: 320 bar
7.4
Solenoid valve
V
Normally open (Manual
emergency operation)
W
Normally closed (Manual
emergency operation)
7.5
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
1)
See chapter Solenoid valves and coils
Example congurations
LWBM200-V1A
l Basic type LWM
l Load signal port B
l LS pressure limitation set to 200 bar
l LS option valve type V, normally open
l 12 V solenoid and connector type AMP Junior Timer
LWSM250-W2D
l Basic type LWM
l Load-Sensing (LS circuit)
l LS pressure limitation set to 250 bar
l LS option valve type W, normally closed
l 24 V solenoid and connector type Deutsch DT04-2P
LWBM200-V1A
LWRM_ _ _-V_ _
LWSM250-W2D
7.1
7.3
7.5
7.2
!
The LS optional ange blocks can
be used only in combination with the
sectional pressure compensator type R
7.4
LS6F / CR160 - 160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRM100-V2D
EN 5.294.0 / 11.21
27
Solenoid valves and coils
Electrohydraulic pilot valves (on/off and proportional): see chapter “Operation units”
Optional valves for ange blocks:
On/Off valves:
With manual emergency operation (push-button)
Valve type V W
Design Poppet valve Poppet valve
Nominal voltage U
N
V DC 12 24 12 24
Nominal current I
N
A 1.50 0.80 2.20 1.10
Min. current I
min
A 1.05 0.56 1.54 0.77
Nominal power P
N
W 18 19 27 27
Response time On: ms 40 30
Off: ms 60 40
Max. permitted voltage deviation from U
N
% ±15
Duty cycle at 115% U
N
% 100
Ambient temperature range
2)
°C -20 to +60
Max. permitted coil temperature
3)
°C 180
Insulation class as per EN 60085 H
Integrated free-wheeling diode Yes Yes
Coil length X mm 40 50
Connector type and IP protection class
(with mating connector mounted)
AMP Junior Timer, 2-pin – axial / up to IP6K6
4)
Deutsch DT04, 2-pin – axial / up to IPX9K
4)
Valve body and coil surface protection Zinc-Nickel (ZnNi)
Proportional pressure relief valve: bleed
screw below coil nut (torque 2.5 + 0.5 Nm)
Valve type P_ _
Nominal voltage U
N
V DC 12 24
Coil resistance at +20 °C (±5%) Ω 4.1 17.6
Max. control current I
max
mA 1,500 750
PWM frequency (recommended)
1)
Hz 150 – 200
Duty cycle at I
max
% 100
Ambient temperature range
2)
°C -20 to + 60
Max. permitted coil temperature
3)
°C 180
Insulation class as per EN 60085 H
Coil length X mm 50
Connector type and IP protection class (with mating connector mounted)
AMP Junior Timer, 2-pin – axial up to IP6K6
4)
Deutsch DT04, 2-pin – axial up to IPX9K
4)
Valve body and coil surface protection Zinc-Nickel (ZnNi)
!
In order to achieve optimal function, any trapped air should
be vented with the bleed screw. Recommended installation
position downwards (suspended for self-ventilation)
12 V: l in mA
24 V: l in mA
p (A/B) in bar
Characteristic curve (measured at 32 mm²/s)
LS pressure limiting function p/l (rising curve)
400 500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500
200 250 300 350 400 450 500 550 600 650 700 750
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
1)
The PWM frequency is to be optimized depending on the application
2)
Deviation of data on inquiry only
3)
Standards ISO 13732-1 and ISO 4413 must be observed in regard
to the surface temperatures occurring on the coils
4)
Mating plug-in connectors are not included
AMP Junior Timer, axial Deutsch DT04, axial
Ø 36.5 X
XØ 36.5
!
The electro-proportional pressure relief valve P_ _
is not suitable for acting as an LS unloading valve.
EN 5.294.0 / 11.21
28
Connection type B
Countersink
Ø in mm
Mono section
M27 P Pump (M27, M17) G 1 50
M17 P Pump (M26P, M16P) G 3/4 44
M26P T Tank G 1 50
M16P A / B Working ports G 3/4 38
MP Pump measuring port (M27, M17) G 1/4 30
MP Pump measuring port (M26P, M16P) G 1/4 25
LS Load sensing G 1/4 30
Z Tank, depressurized G 1/4 30
C Pilot oil supply G 1/4 30
Inlet section
ML27 P Pump (ML27, ML17) G 1 50
ML17 P Pump (ML26P, ML16P) G 3/4 44
ML26P T Tank G 1 50
ML16P A / B Working ports G 3/4 38
MP Pump measuring port (ML27, ML17) G 1/4 30
MP Pump measuring port (ML26P, ML16P) G 1/4 25
LS Load sensing G 1/4 30
Z Tank, depressurized G 1/4 30
Single sections
A / B Working ports G 3/4 38
Operation unit
H ... X / Y Hydraulic operation port
(spool position a / b)
G 1/4 25
C1X MX Pilot pressure measuring port
(spool position a)
G 1/8 15
EY ... MY Pilot pressure measuring port
(spool position b)
G 1/8 15
End section
SR16C A / B Working ports G 3/4 38
SR16 C Pilot oil supply G 1/4 25
Fastening:
The control valve must be mounted at three (mono section at two) xation points without tensioning. see also section “Dimensions”
Fastening thread B
Mono section
M27 / M17 / M26P / M16P
Inlet section
ML27 / ML17 / ML26P / ML16P
2 x 15 mm deep M10x1.5
End section
SR16C
1 x 15 mm deep M10x1.5
SR16
Connection type, fastening and tie rods
Type code
1 2 3 4
1
Valve type
2
Specication type
_ _
Complete control valve
No. of working sections (01-10)
0X
Single modules
(Inlet / single / end section / optional block)
3
Connection type
B
BSPP acc. to ISO 1179-1
(SAE on inquiry only)
4
Valve series
!
Only use ttings with deformable seal materials
Installation, usage, and maintenance information
Installation, adjustment, maintenance must be done by authorized and trained staff.
The use of this product outside the specied technical limits, use of non specied uids and/or
use of not genuine spare parts will cause the expiration of the warranty.
LCX-6 03 / B 0
Fastening screws:
Property class 10.9
Fastening torque Nm 72
± 5 %
Tie rod:
M10 tie rod with ange nut WAF 16 M
Z
= 40 ±5 %
or hexagon socked head screws WAF 8 M
Z
= 40 ±5 %
!
Only use of genuine LCX-6 tie rod kits.
EN 5.294.0 / 11.21
29
Dimensions
All dimensions in mm, subject to change.
Example for control valve with mono section
Connector types: AMP Junior Timer, 2-pin, axial
28
46.592
96
98.5
278
307
X
Y
96.5
66.5
54
35.5
19
42
90.5
97
123.5
175
31.5
67
28
17.5
1.1
Mono section M27 - CS6
2.7
Electrohydraulic operation EYHS, E1YHS
2.8
Spring cap C1E
LS
Combined LS pressure limitation port A / B
MY
Pilot pressure measuring port
SA
Secondary valve port A
SB
Secondary valve port B
4.0
Type plate
4.1
1 x M10 x 1.5 – 15 deep for crane gear
Pilot valve
port B
Pilot valve
port A
Stroke limiter port A
clockwise rotation for limitation
(Dimension X for max. stroke: 25)
Stroke limiter port B
counterclockwise rotation for limitation
(Dimension Y for max. stroke: 13)
Standard lever, short
(Emergency operation)
4.1
LS pressure
relief valve
LS
SB
4.0
SA
2.8
MY
2.7
1.1
EN 5.294.0 / 11.21
30
Dimensions
All dimensions in mm, subject to change.
Example for control valve with inlet section, single sections and end section
Connector types: AMP Junior Timer, 2-pin, axial
1.2
Inlet section ML26P - CS6
2.1
Single section B6
2.2
Single section CS6
2.7
Electrohydraulic operation ES, E1S
2.8
Spring cap C1E
3.2
End section SR16C - CS6
32.5
46.592
51
92.5
96
98.5
88
50
35.5
278
X
Y
54.5
248
46 48
36 27.5
20.5
90.5
123.5
175
67
26.5
17.5
Stroke limiter port A
clockwise rotation for limitation
(Dimension X for max. stroke: 25)
Stroke limiter port B
counterclockwise rotation for limitation
(Dimension Y for max. stroke: 13)
LS
Combined LS pressure limitation port A / B
SA
Secondary valve port A
SB
Secondary valve port B
4.0
Type plate
4.1
2 x M10 x 1.5 – 15 deep for crane gear
4.0
4.1
2.7
Pilot valve
port B
Pilot valve
port A
1.2 2.2 2.1 3.2
2.8
SA
LS
4.1
SB
EN 5.294.0 / 11.21
31
Dimensions
All dimensions in mm, subject to changes.
Hand lever: neutral positions and max. travel (see also chapter “Operation units”)
Control valve fastening points (2 x or 3 x M10 x 1.5 – 15 deep)
The fastening points are equal for all types of inlet and end sections
Neutral positions: for all hand lever types 1 – 3: Max. travel for port A / port B
ca. 30°
43.5°
80°
ca. 30°
19.5°
19.5°
Port B
Port A
Shown: Standard lever, short (emergency operation) – Type 2
No. of working sections 2 3 4 5 6 7 8 9 10
L mm 52 100 148 196 244 292 340 388 436
L
123 25
83.5
60
28
83.528
52.528
EN 5.294.0 / 11.21
32
Type code
Structure and sequence: 1. General (control valve always dened from left to right)
2. Mono or Inlet section
3. Single section 1
Single section 2
Single section n
4. End section
1. General
Valve type: LCX-6 03 / B 0
Pos. 1 2 3 4
Pos. / designation: Type code: Description / function Comment:
1 Load-sensing valve series LCX-6 Load-sensing Compact X-series Size 6
2 No. of working sections
Specication/identication of single modules
_ _ 2-digit, 01 10 Max. 10 working sections
0X Inlet / single / end section or optional ange block
3 Connection thread
B BSPP acc. to ISO 1179-1 (SAE on inquiry only)
4 Valve series 0 Unchanged installation and connection dimensions
2. Mono section
Type: M27 - CS6 ...
M17 - CS6 ...
M26P / 250 - CS6 ...
M16P / 300 - CS6 ...
Pos. 1 2 ... see main point 3 “Single sections” next page
Pos. / designation: Type code: Description / function Comment:
1 Basic type
Standard mono section M27 Mono section 2 Internal pilot oil supply 7 Port size P/T Port size P: BSPP G1
M17 Mono section 1 External pilot oil supply 7 Port size P/T Port size T: BSPP G1
Mono section with pressure peak protection M26P Mono section 2 Internal pilot oil supply 6 Port size P Pressure peak protection Port size P: BSPP G 3/4
M16P Mono section 1 External pilot oil supply 6 Port size P Pressure peak protection Port size T: BSPP G1
2 Pressure peak protection
_ _ _
Shock / anti-cavitation valve for port P in bar, 3-digit
2. Inlet section
Type: ML27 / - CS6 ...
ML17 / - CS6 ...
ML26P / 250 - CS6 ...
ML16P / 300 - CS6 ...
Pos. 1 2 ... see main chart 3 “Single sections” next page
Pos. / designation: Type code: Description / function Comment:
1 Basic type
Standard Inlet section ML27 Multi inlet Left hand 2 Internal pilot oil supply 7 Port size P/T Port size P: BSPP G1
ML17 Multi inlet Left hand 1 External pilot oil supply 7 Port size P/T Port size T: BSPP G1
Inlet section with pressure peak protection ML26P Multi inlet Left hand 2 Internal pilot oil supply 6 Port size P P
ressure peak protection
Port size P: BSPP G 3/4
ML16P Multi inlet Left hand 1 External pilot oil supply 6 Port size P P
ressure peak protection
Port size T: BSPP G1
2 Pressure peak protection
_ _ _
Shock / anti-cavitation valve for port P in bar, 3-digit
EN 5.294.0 / 11.21
33
3. Single sections
Type Single section 1 B6 / CR 160 – 160 RN / EYHS2A - 1 / C1E
Single section 2 CS6 / CS 160 – 160 RN / 250 / 300 – 300 / EYHS2A - 1 / C1E
Single section 3 LS6 / CS 150 – 035 RN / 300 – 200 / P – P / EYHS2A / C1E
Single section 4 LS6F / CR 060 – 060 RY / 300 – 300 / 350 – 350 / HHS - 1 / C1H / LWRV2A
Single section 5 / / / ...
Pos. 1 2 3 4 5 6 7 8 9 10
Pos. / designation: Type code: Description / function Comment:
1. Basic type
Basic section w/o optional valves B6 Basic section 6 port size A/B Port size 6
Section like B6 with optional valves CS6
Like B6 with Combined LS pressure limitation
and Shock/anti-cavitation valves
BSPP: G3/4
Section like B6 with optional valves LS6 Like B6 with LS pressure limitation and Shock/anti-cavitation valves
Section like LS6 with optional block LS6F Like LS6 with Flange interface for optional ange block
2. Main spool
CS Cylinder spool Standard Pos. 0: A, B closed
CR Cylinder spool Released Pos. 0: A, B unloaded to T
MS Motor spool Standard Pos. 0: A, B open to T
...
For other types, see chapter
“Main spool and pressure compensator”
3. Max. ow rate to actuator A B
See chapter “Main spool valve
and pressure compensator”
1) _ _ _ - _ _ _ Maximum ow to port A / B in l/min, 3-digit
4. Pressure compensator axis (spool + spring)
Pressure compensator – released
with load holding function (standard)
RY Released pressure compensator Y spring identier yellow 9.5 – 11.5 bar
RB B spring identier blue 8.0 – 10.0 bar
RN N spring identier unmarked 7.0 – 9.0 bar (nominal)
RG G spring identier green 5.5 – 7.5 bar
Pressure compensator – released
with load holding function (standard)
and measuring port LR for sectional
load-sensing pressure
RYM Like RY with M measuring port LR 9.5 – 11.5 bar
RBM Like RB with M measuring port LR 8.0 – 10.0 bar
RNM Like RN with M measuring port LR 7.0 – 9.0 bar (nominal)
RGM Like RG with M measuring port LR 5.5 – 7.5 bar
Load holding function L Load holding function only w/o pressure compensation Use of compensator spring type G
5. LS pressure limitation A B
!
For basic types CS6, LS6 and LS6F only
_ _ _ - _ _ _ Pressure setting for port A / B in bar, 3-digit (mechanically adjustable) Min. 050 bar, max. 320 bar
P Plug screw w/o LS pressure limitation
6. Workport valves A B
!
For basic types CS6, LS6 and LS6F only
_ _ _ - _ _ _ Shock/ anti-cavitation valve for port A / B in bar, 3-digit See chapter “Workport valves”
A Anti-cavitation valve
P Plug screw
w/o workport valves
7. Operation units
MHS Manual Hand lever axis Stroke limiter
HHS Hydraulic Hand lever axis Stroke limiter
EYHS Electrohydraulic MY port Hand lever axis Stroke limiter Pilot pressure MY – spool position (b)
E1YHS Electrohydraulic 1 dampened MY port Hand lever axis Stroke limiter Dampening setup 1 – orice 1.0 mm
ES Electrohydraulic Stroke limiter
E1S Electrohydraulic 1 dampened Stroke limiter Dampening setup 1 – orice 1.0 mm
!
For operation unit E... only
Supply voltage DC
1 _ 12 V
2 _ 24 V
Connector type
_ A AMP – Junior Timer, 2-pin, axial
_ D Deutsch – DT04, 2-pin, axial
8. Hand lever type
Levers not assembled during shipment
!
For operation types _ H _ only n/a No hand lever
Standard lever 1 Standard See chapter “Operation units”
Standard lever, short
2 Standard for emergency operation
Universal clamp without hand lever
3 For application-specic solutions
Universal clamp with standard lever
31 Lever orientation: left
32 Lever orientation: top
33 Lever orientation: right
9. Spring caps
Standard for operation unit M ... C1M C Standard cap 1 Version Manual
Standard for operation unit H ... C1H C Standard cap 1 Version Hydraulic Pilot pressure range: 6.5 20 bar
Standard for operation unit E ... C1E C Standard cap 1 Version Electrohydraulic Pilot pressure range: 4.5 20 bar
Option for operation unit E ...
C1XE C Standard cap 1 Version MX port E Electrohydraulic Pilot pressure MX – spool position (a)
Type code
1)
Deviation of data on inquiry only
EN 5.294.0 / 11.21
34
10 Optional ange blocks
!
For basic type LS6F only
For channel:
LA Load signal port A
LB Load signal port B
LR Load signal port A and B
or
LS Load Sensing
(LS circuit)
LD1 Dummy plate 1 version
LW _ V _ _
LS unloading LWA, LWB, LWR or LWS channel
Valve type V
Normally open
LW _ W _ _
LS unloading LWA, LWB, LWR or LWS channel
Valve type W
Normally closed
LW _ P0A _ _
Electro-prop. pres. adj. LWA, LWB, LWR or LWS channel
Orice setup: 1.0 mm Pressure stage A: 350 bar Valve type P
Rising curve
LW _ M _ _ _ V _ _
Second pressure stage LWA, LWB, LWR or LWS channel
(On/Off) Mech. adjustable in bar, 3-digit Valve type V
Second pressure level
when de-energized
LW _ M _ _ _ W _ _
Second pressure stage LWA, LWB, LWR or LWS channel
(On/Off) Mech. adjustable in bar, 3-digit Valve type W
Second pressure level
when energized
For channel:
LA and LB
LW1 V - V _ _
LW1 basic type Load signal port A - Load signal port B
Valve type V – normally open Valve type W – normally closed
Valve type V and W selected
as desired
Supply voltage DC
1 _ 12 V
2 _ 24 V
Connector type
_ A AMP – Junior Timer, 2-pin, axial
_ D Deutsch – DT04, 2-pin, axial
4. End section
Type:
SR16C - C6 ...
SR16C - CS6 ...
SR16 - C6 ...
SR16 - CS6 ...
Pos.
1 see main chart 3 “Single sections” previous page
Pos./designation: Type code: Description / function Comment
1 Basic type
Standard end section
for internal pilot oil supply
SR16C Section Right 1 Version 1 6 Port size A / B C Port plugged
Port size 6
BSPP: G1
Standard end section
for external pilot oil supply
SR16 Section Right 1 Version 1 6 Port size A / B
Type code
Example for control valve with mono section
(see also chapter “Dimensions”)
Example for control valve
with inlet section, single sections and end section
(see also chapter “Dimensions”)
EN 5.294.0 / 11.21
35
Ordering examples
General LCX-601/B0
Mono section M27
CS6/CS160-160RN/250/300-300/EYHS2A-2/C1E
General LCX-604/B0
Inlet section ML26P/300
CS6/CR160-160RN/210/240-240/ES1A/C1E
Single section 1 CS6/CS110-110RN/180/210-210/ES1A/C1E
Single section 2 B6
/MS050-050RG /ES1A/C1E
End section SR16C
CS6/CS050-050RG/120/140-140/ES1A/C1E
Example for control valve with mono section
(see also chapter “Dimensions”)
Example for control valve with inlet section, single sections and end section
(see also chapter “Dimensions”)
BA
B
A
P
T
MP
LS
C
Z
A/B
MY
BABA
B
A
BA
B
A
P
T
MP
LS
Z
A /B
T
Z
C
P
LX
LS
BA
B
A
C
Z
C
A /B A /B
T
P
LX
LS
EN 5.294.0 / 11.21
36
Note
The information in this brochure
relates to the operating conditions
and applications described.
For applications and operating conditions
not described. please contact the relevant
technical department.
Subject to technical and other changes.
Head Ofce Industriegebiet
HYDAC INTERNATIONAL 66280 Sulzbach/Saar
GMBH Germany
Tel.: +49 6897 509-01
Fax: +49 6897 509-300
E-mail: mobilevalves@hydac.com