Technical data
Input data AB C
Measurement ranges bar 16 25 40 60 100 250 400 600
Overload pressures bar 32 50 80 120 200 500 800 1000
Burst pressure bar 125 125 200 300 500 1250 2000 2000
Mechanical connection G 1/4 A ISO 1179-2, external thread
Tightening torque, recommended 20 Nm
Parts in contact with fluid Connector: Stainless steel
Seal: FKM
Output data
Output signal IO-Link V1.1
Additional switching output or analogue output as an option
Switching output PNP Transistor switching output
(parameterisable: PNP, NPN or Push-Pull)
Further optional Push-Pull transistor switching output
Switching current: max. 250 mA per switching output
Analogue output, permitted load 4 .. 20 mA, R
Lmax
= U
B
– 8V / 20 mA [kΩ], load max. 500 Ω
0 .. 10 V, R
Lmin
= 2 kΩ,
Accuracy
1)
acc. to DIN 16086,
Terminal based
2)
≤ ± 0.5 % FS typ.
≤ ± 1.0 % FS max.
Accuracy
2)
acc. to minimum value setting
(B.F.S.L.)
≤ ± 0.25 % FS typ.
≤ ± 0.5 % FS max.
Temperature compensation zero point ≤ ± 0.015 % FS / °C typ.
≤ ± 0.025 % FS / °C max.
Temperature compensation span ≤ ± 0.015 % FS / °C typ.
≤ ± 0.025 % FS / °C max.
Rise time ≤ 5 ms
Long-term drift ≤ ± 0.3 % FS typ. / year
Environmental conditions / Approvals / Tests
Compensated temperature range -25 .. +85 °C
Operating temperature range
3)
-40 .. +100 °C / -25 .. +100 °C
Storage temperature range -40 .. +100 °C
Fluid temperature range
3)
-40 .. +125 °C / -25 .. +125 °C
EMC DIN EN 61000-6-1/ 2/ 3/ 4
Vibration resistance DIN EN 60068-2-6 ≤ 25 g (10 .. 500 Hz)
Shock resistance DIN EN 60068-2-27 100 g / 6 ms / half sine
500 g / 1 ms / half sine
Protection type
4)
DIN EN 60529 IP 67
/ conformity
Provided
approval
Provided
Other data
Supply voltage
when applied acc. to UL specifications
9 .. 35 V DC, if PIN 2 = SP2
18 .. 35 V DC, if PIN 2 = Analogue output
(each 18 .. 30 V DC for communication operation)
- limited energy – acc. to 9.3 UL 61010; Class 2;
UL 1310 / 1585; LPS UL 60950
Residual ripple of supply voltage ≤ 5 %
Current consumption ≤ 25 mA
Life expectancy > 10 million load cycles (0 .. 100 % FS)
Weight ~ 45 g
Note: Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.
FS (Full Scale) = relative to complete measuring range
B.F.S.L. = Best Fit Straight Line
1) The accuracy indications refer to the –measured value (process value or ISDU Index 112, Subindex 1).
2) Including non-linearity, hysteresis, offset and final value deviation
3) In the standard up to -25 °C with FKM seal, -40 °C on request
4) With mounted mating connector in corresponding protection type